{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T12:44:33Z","timestamp":1775565873090,"version":"3.50.1"},"reference-count":0,"publisher":"Press of International Journal of Ophthalmology (IJO Press)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Ophthalmol"],"published-print":{"date-parts":[[2021,1,18]]},"abstract":"<jats:p>AIM: To evaluate the refractive and long-term outcome of eyes filled with silicone oil (SO) undergoing phacoemulsification cataract surgery (PCS).\nMETHODS: This retrospective study evaluated patients with SO tamponade who were scheduled for PCS.\nRESULTS: Subjects (n=26) were followed for 29.5\u00b113.9mo after cataract surgery. The median spherical equivalent refraction (SER) was +5.3 D [interquartile range (IQR) +2.9 to +6.7] before PCS, and +3.4 D (IQR +2.0 to +4.4) after PCS. Within the follow-up period retinal reattachment after SO removal was achieved in 15 out of 26 eyes (57.7%). In 13 eyes assessment of refraction after SO-removal was possible, and showed a myopic shift of -4.6 D (IQR -2.9 to -7.3) in the SER. After SO removal, 5 of the 13 eyes (38.5%) were within \u00b11.0 D of the target refraction, while 9 out of the 13 eyes (69.2%) were within \u00b12.0 D.\nCONCLUSION: In our study, the refraction after PCS for eyes filled with SO manifested low predictability, as did the myopic shift following SO removal. A significant percentage of the eyes that underwent SO administration required a long-term tamponade.<\/jats:p>","DOI":"10.18240\/ijo.2021.01.10","type":"journal-article","created":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T06:01:28Z","timestamp":1609653688000},"page":"72-75","source":"Crossref","is-referenced-by-count":2,"title":["Long-term follow-up of cataract surgery in eyes filled with silicone oil"],"prefix":"10.18240","volume":"14","author":[{"name":"Hygeia Clinic, Gda&#x144;sk 80-286, Poland","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piotr","family":"Kanclerz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrzej","family":"Grzybowski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Ophthalmology, University of Warmia and Mazury, Olsztyn 10-082, Poland; Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan 60-554, Poland","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pawe\u0142","family":"Lipowski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Ophthalmology, Medical University of Gda&#x144;sk, Gda&#x144;sk 80-952, Poland","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"7543","container-title":["International Journal of Ophthalmology"],"original-title":[],"link":[{"URL":"http:\/\/ies.ijo.cn\/en_publish\/2021\/1\/20210110.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T06:01:37Z","timestamp":1609653697000},"score":1,"resource":{"primary":{"URL":"http:\/\/ies.ijo.cn\/gjyken\/ch\/reader\/view_abstract.aspx?file_no=20210110&flag=1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,18]]},"references-count":0,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1,18]]}},"URL":"https:\/\/doi.org\/10.18240\/ijo.2021.01.10","relation":{},"ISSN":["2222-3959","2227-4898"],"issn-type":[{"value":"2222-3959","type":"print"},{"value":"2227-4898","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,18]]}}}