{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T21:01:08Z","timestamp":1792011668708,"version":"4.4.0"},"reference-count":0,"publisher":"Press of International Journal of Ophthalmology (IJO Press)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Ophthalmol"],"published-print":{"date-parts":[[2022,10,18]]},"abstract":"<jats:p>AIM: To investigate the one-year refractive outcomes and optical quality following PRESBYOND laser-blended vision (LBV).\nMETHODS: This retrospective study included 20 patients who underwent PRESBYOND treatment between Jan 2019 and Aug 2020. The patients were asked to attend a follow-up outpatient visit one year after surgery. Distance and near visual acuity as well as subjective refraction were examined. Optical quality was assessed using wavefront-supported custom ablation. A questionnaire evaluating optical quality and satisfaction was completed at the last visit.\nRESULTS: The average patient age was 48.1\u00b17.4y (range, 41 to 58y). The mean preoperative spherical equivalent was -7.59\u00b12.39 D. At the one-year follow-up, two eyes (both dominant eyes) lost one line of corrected distance visual acuity (CDVA), while the remaining eyes (38\/40) maintained or gained lines of CDVA. The average binocular uncorrected distance visual acuity improved from 0.15\u00b10.03 to 0.90\u00b10.26 (decimal vision; P&amp;#x003C;0.001). The average binocular uncorrected near visual acuity increased from 0.34\u00b10.28 to 0.97\u00b10.07 (P&amp;#x003C;0.001). The spherical aberration was 0.04\u00b10.06 \u03bcm in the nondominant eye and 0.09\u00b10.09 \u03bcm in the dominant eye (P=0.02). All patients were satisfied with or accepted the outcomes of the surgery. The primary complaints were related to disturbances in night vision and relatively inferior near vision.\nCONCLUSION: Over the one-year observation period, PRESBYOND is a safe and effective option for presbyopia correction. The optical quality and near vision deserve further investigation.<\/jats:p>","DOI":"10.18240\/ijo.2022.10.16","type":"journal-article","created":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T23:37:16Z","timestamp":1663803436000},"page":"1671-1675","source":"Crossref","is-referenced-by-count":11,"title":["Refractive outcomes and optical quality of PRESBYOND laser-blended vision for presbyopia correction"],"prefix":"10.18240","volume":"15","author":[{"name":"Eye Institute and Department of Ophthalmology, Eye &#x0026; ENT Hospital, Fudan University, Shanghai 200030, China; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan","family":"Fu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Eye Institute and Department of Ophthalmology, Eye &#x0026; ENT Hospital, Fudan University, Shanghai 200030, China; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Eye Institute and Department of Ophthalmology, Eye &#x0026; ENT Hospital, Fudan University, Shanghai 200030, China; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Eye Institute and Department of Ophthalmology, Eye &#x0026; ENT Hospital, Fudan University, Shanghai 200030, China; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xing-Tao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Eye Institute and Department of Ophthalmology, Eye &#x0026; ENT Hospital, Fudan University, Shanghai 200030, China; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"7543","container-title":["International Journal of Ophthalmology"],"original-title":[],"link":[{"URL":"http:\/\/ies.ijo.cn\/en_publish\/2022\/10\/20221016.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T23:37:39Z","timestamp":1663803459000},"score":1,"resource":{"primary":{"URL":"http:\/\/ies.ijo.cn\/gjyken\/ch\/reader\/view_abstract.aspx?file_no=20221016&flag=1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,18]]},"references-count":0,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022,10,18]]}},"URL":"https:\/\/doi.org\/10.18240\/ijo.2022.10.16","relation":{},"ISSN":["2222-3959","2227-4898"],"issn-type":[{"value":"2222-3959","type":"print"},{"value":"2227-4898","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,18]]}}}