{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T01:02:53Z","timestamp":1771894973375,"version":"3.50.1"},"reference-count":0,"publisher":"Press of International Journal of Ophthalmology (IJO Press)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Ophthalmol"],"published-print":{"date-parts":[[2024,6,18]]},"abstract":"<jats:p>AIM: To investigate the influence of ophthalmic viscoelastic devices (OVDs) and different surgical approaches on the intraocular pressure (IOP) before and after creation of the curvilinear circular capsulorhexis (CCC) as a measure for anterior chamber stability during this maneuver.\nMETHODS: Prospective experimental WetLab study carried out on enucleated porcine eyes. IOP was measured before and after CCC with the iCare Rebound tonometer (iCare ic200; iCare Finland Oy, Vantaa, Finland). The OVDs used were a cohesive one [Z-Hyalin, Carl Zeiss Meditec AG, Germany; hyaluronic acid (HA)] and a dispersive [Z-Celcoat, Carl Zeiss Meditec AG, Germany; hydroxy propylmethylcellulosis (HPMC)]. The CCC was created using Utrata forceps or 23 g microforceps in different combinations with the OVDs.\nRESULTS: Using the Utrata forceps the IOP dropped from 63.65\u00b16.44 to 11.25\u00b13.63 mm Hg during the CCC. The use of different OVDs made no difference. Using the 23 g microforceps the IOP dropped from 65.35\u00b18.15 to 36.55\u00b16.09 mm Hg. The difference between IOP drop using either Utrata forceps or 23 g microforceps was highly significant regardless of the OVD used.\u00a0\nCONCLUSION: Using the sideport for the creation of the capsulorhexis leads to a lesser drop in IOP during this maneuver compared to the main incision in enucleated porcine eyes. The use of different OVD has no significant influence on IOP drop.<\/jats:p>","DOI":"10.18240\/ijo.2024.06.22","type":"journal-article","created":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T08:40:09Z","timestamp":1716540009000},"page":"1156-1160","source":"Crossref","is-referenced-by-count":2,"title":["Intraocular pressure before and after capsulorhexis using two viscoelastic substances and two surgical approaches in enucleated porcine eyes"],"prefix":"10.18240","volume":"17","author":[{"name":"Augenzentrum Osthessen, Fulda 36037, Germany","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiraz Ben","family":"Abdallah","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus S.","family":"Ladewig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"University Eye Hospital Philipps-University, Campus Fulda, Fulda 36043, Germany","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel M.","family":"Handzel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Augenzentrum Osthessen, Fulda 36037, Germany","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"7543","container-title":["International Journal of Ophthalmology"],"original-title":[],"link":[{"URL":"http:\/\/ies.ijo.cn\/en_publish\/2024\/6\/20240622.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T08:40:41Z","timestamp":1716540041000},"score":1,"resource":{"primary":{"URL":"http:\/\/ies.ijo.cn\/gjyken\/ch\/reader\/view_abstract.aspx?file_no=20240622&flag=1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,18]]},"references-count":0,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6,18]]}},"URL":"https:\/\/doi.org\/10.18240\/ijo.2024.06.22","relation":{},"ISSN":["2222-3959","2227-4898"],"issn-type":[{"value":"2222-3959","type":"print"},{"value":"2227-4898","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,18]]}}}