{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T01:37:51Z","timestamp":1787621871607,"version":"build-2736575974"},"reference-count":21,"publisher":"Fuji Technology Press Ltd.","issue":"6","funder":[{"DOI":"10.13039\/100009619","name":"Japan Agency for Medical Research and Development","doi-asserted-by":"publisher","award":["JP21hm0102078s0102"],"award-info":[{"award-number":["JP21hm0102078s0102"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100009619","name":"Japan Agency for Medical Research and Development","doi-asserted-by":"publisher","award":["JP22hm0102078s0103"],"award-info":[{"award-number":["JP22hm0102078s0103"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008884","name":"Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008884","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JRM","J. Robot. Mechatron."],"published-print":{"date-parts":[[2024,12,20]]},"abstract":"<jats:p>Forceps-type mini-positron emission tomography (mini-PET) has been proposed as an intraoperative device for examining metastatic lymph nodes in the treatment of esophageal cancer. Although this forceps-type mini-PET detects cancer by radiation measurement, the scissor-like tip of the device affects the measurement accuracy. Therefore, to improve the detection sensitivity of the forceps-type mini-PET without depending on the operator, we fabricated a forceps tip mechanism using a parallel-link for parallel opening and closing motions, and verified the parallel motion and the force required for opening and closing. Consequently, we confirmed parallel motion from the opening and closing widths of the tip detectors. In addition, we confirmed that the forces required for opening and closing were significantly smaller than those required for the conventional mechanism.<\/jats:p>","DOI":"10.20965\/jrm.2024.p1550","type":"journal-article","created":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T15:02:09Z","timestamp":1734620529000},"page":"1550-1557","source":"Crossref","is-referenced-by-count":1,"title":["Operational Verification of a Parallel Open\/Closeable Forceps Tip Mechanism for Forceps-Type Mini-PET"],"prefix":"10.20965","volume":"36","author":[{"given":"Hiroto","family":"Hayashi","sequence":"first","affiliation":[{"name":"Graduate School of Science and Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba, Chiba 263-8522, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2736-1311","authenticated-orcid":true,"given":"Kazuya","family":"Kawamura","sequence":"additional","affiliation":[{"name":"Center for Frontier Medical Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba, Chiba 263-8522, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeki","family":"Ito","sequence":"additional","affiliation":[{"name":"Mirai-Imaging Corporation, 1-24 Uchigomimayamachi, Iwaki, Fukushima 973-8402, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1953-7428","authenticated-orcid":true,"given":"Miwako","family":"Takahashi","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Chiba 263-8555, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taiga","family":"Yamaya","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Chiba 263-8555, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"8550","published-online":{"date-parts":[[2024,12,20]]},"reference":[{"key":"key-10.20965\/jrm.2024.p1550-1","doi-asserted-by":"crossref","unstructured":"Y. Tachimori et al., \u201cEfficacy of lymph node dissection by node zones according to tumor location for esophageal squamous cell carcinoma,\u201d Esophagus, Vol.13, No.1, pp. 1-7, 2016. https:\/\/doi.org\/10.1007\/s10388-015-0515-3","DOI":"10.1007\/s10388-015-0515-3"},{"key":"key-10.20965\/jrm.2024.p1550-2","doi-asserted-by":"crossref","unstructured":"M. Tachibana et al., \u201cClinical outcomes of extended esophagectomy with three-field lymph node dissection for esophageal squamous cell carcinoma,\u201d The American J. of Surgery, Vol.189, No.1, pp. 98-109, 2005. https:\/\/doi.org\/10.1016\/j.amjsurg.2004.10.001","DOI":"10.1016\/j.amjsurg.2004.10.001"},{"key":"key-10.20965\/jrm.2024.p1550-3","unstructured":"M. Takahashi, \u201cNuclear medicine for intraoperative lymph node diagnosis,\u201d Report on PET Imaging Physics Research, pp. 83-90, 2020."},{"key":"key-10.20965\/jrm.2024.p1550-4","unstructured":"M. Yamazaki, \u201cCurrent status of surgical treatment for esophageal cancer,\u201d J. of the Japanese Society of Gastroenterology, Vol.116, No.2, pp. 123-128, 2019 (in Japanese). https:\/\/doi.org\/10.11405\/nisshoshi.116.123"},{"key":"key-10.20965\/jrm.2024.p1550-5","doi-asserted-by":"crossref","unstructured":"Y. Seto, \u201cEssential updates 2018\/2019: Essential updates for esophageal cancer surgery,\u201d Annals of Gastroenterological Surgery, Vol.4, No.3, pp. 190-194, 2020. https:\/\/doi.org\/10.1002\/ags3.12319","DOI":"10.1002\/ags3.12319"},{"key":"key-10.20965\/jrm.2024.p1550-6","doi-asserted-by":"crossref","unstructured":"M. Takahashi et al., \u201cA design of forceps-type coincidence radiation detector for intraoperative LN diagnosis: Clinical impact estimated from LNs data of 20 esophageal cancer patients,\u201d Annals of Nuclear Medicine, Vol.36, No.3, pp. 285-292, 2022. https:\/\/doi.org\/10.1007\/s12149-021-01701-9","DOI":"10.1007\/s12149-021-01701-9"},{"key":"key-10.20965\/jrm.2024.p1550-7","doi-asserted-by":"crossref","unstructured":"Y. Kakeji et al., \u201cSurgical outcomes in gastroenterological surgery in Japan: Report of the National Clinical Database 2011\u20132018,\u201d Annals of Gastroenterological Surgery, Vol.4, No.3, pp. 250-274, 2020. https:\/\/doi.org\/10.1002\/ags3.12324","DOI":"10.1002\/ags3.12324"},{"key":"key-10.20965\/jrm.2024.p1550-8","doi-asserted-by":"crossref","unstructured":"H. Kawai et al., \u201cUsefulness and limitation of FDG-PET \/ CT, and comparison with MRI in diagnosis of cardiac sarcoidosis,\u201d The Japanese J. of Sarcoidosis and Other Granulomatous Disorders, Vol.39, No.1, pp. 59-64, 2019 (in Japanese). https:\/\/doi.org\/10.7878\/jjsogd.39.1_2_59","DOI":"10.7878\/jjsogd.39.1_2_59"},{"key":"key-10.20965\/jrm.2024.p1550-9","doi-asserted-by":"crossref","unstructured":"S. Yoshimura et al., \u201cOne-by-one comparison of lymph nodes between 18F-FDG uptake and pathological diagnosis in esophageal cancer,\u201d Clinical Nuclear Medicine, Vol.45, No.10, pp. 741-746, 2020. https:\/\/doi.org\/10.1097\/RLU.0000000000003224","DOI":"10.1097\/RLU.0000000000003224"},{"key":"key-10.20965\/jrm.2024.p1550-10","doi-asserted-by":"crossref","unstructured":"S. Matsuda, H. Takeuchi, H. Kawakubo, and Y. Kitagawa, \u201cThree-field lymph node dissection in esophageal cancer surgery,\u201d J. of Thoracic Disease, Vol.9, No.Suppl.8, pp. S731-S740, 2017. https:\/\/doi.org\/10.21037\/jtd.2017.03.171","DOI":"10.21037\/jtd.2017.03.171"},{"key":"key-10.20965\/jrm.2024.p1550-11","doi-asserted-by":"crossref","unstructured":"K. Kudo et al., \u201cColumnar metaplasia in the remnant esophagus is a long-term indicator for pneumonia after radical esophagectomy,\u201d Esophagus, Vol.15, No.1, pp. 27-32, 2018. https:\/\/doi.org\/10.1007\/s10388-017-0590-8","DOI":"10.1007\/s10388-017-0590-8"},{"key":"key-10.20965\/jrm.2024.p1550-12","doi-asserted-by":"crossref","unstructured":"E. Booka et al., \u201cThe impact of postoperative complications on survivals after esophagectomy for esophageal cancer,\u201d Medicine, Vol.94, No.33, Article No.e1369, 2015. https:\/\/doi.org\/10.1097\/MD.0000000000001369","DOI":"10.1097\/MD.0000000000001369"},{"key":"key-10.20965\/jrm.2024.p1550-13","unstructured":"A. Nakajima, K. Kawamura, S. Ito, M. Takahashi, and T. Yamaya, \u201cCount rate measurement of a forceps-type mini-PET with varying the tip angle,\u201d Annals of Japan Society of Computer Aided Surgery 2022, 2022."},{"key":"key-10.20965\/jrm.2024.p1550-14","doi-asserted-by":"crossref","unstructured":"H. Hayashi, K. Kawamura, S. Ito, M. Takahashi, and T. Yamaya, \u201cDevelopment of a forceps tip mechanism capable of parallel open\/close motion for the development of forceps-type mini PET,\u201d Proc. of 2023 JSME Annual Conf. on Robotics and Mechatronics (Robomec), Article No.2P2-C10, 2023 (in Japanese). https:\/\/doi.org\/10.1299\/jsmermd.2023.2P2-C10","DOI":"10.1299\/jsmermd.2023.2P2-C10"},{"key":"key-10.20965\/jrm.2024.p1550-15","doi-asserted-by":"crossref","unstructured":"M. Dziuk et al., \u201cDetermining the optimal dose of 18F-FDG for Hodgkin lymphoma imaging on PET\/CT camera with BGO crystals,\u201d Research Square, 2020. https:\/\/doi.org\/10.21203\/rs.3.rs-89841\/v1","DOI":"10.21203\/rs.3.rs-89841\/v1"},{"key":"key-10.20965\/jrm.2024.p1550-16","doi-asserted-by":"crossref","unstructured":"C. Jiang et al., \u201cFlexible parallel link mechanism using tube-type dielectric elastomer actuators,\u201d J. Robot. Mechatron., Vol.27, No.5, pp. 504-512, 2015. https:\/\/doi.org\/10.20965\/jrm.2015.p0504","DOI":"10.20965\/jrm.2015.p0504"},{"key":"key-10.20965\/jrm.2024.p1550-17","doi-asserted-by":"crossref","unstructured":"J.-P. Merlet, \u201cParallel Robots,\u201d Kluwer Academic Publishers, 2000.","DOI":"10.1007\/978-94-010-9587-7"},{"key":"key-10.20965\/jrm.2024.p1550-18","doi-asserted-by":"crossref","unstructured":"Y. Takeda et al., \u201cDevelopment of position-orientation decoupled spatial in-parallel actuated mechanisms with six degrees of freedom,\u201d J. Robot. Mechatron., Vol.17, No.1, pp. 59-68, 2005. https:\/\/doi.org\/10.20965\/jrm.2005.p0059","DOI":"10.20965\/jrm.2005.p0059"},{"key":"key-10.20965\/jrm.2024.p1550-19","doi-asserted-by":"crossref","unstructured":"T. Onodera, E. Suzuki, M. Ding, H. Takemura, and H. Mizoguchi, \u201cForce, stiffness and viscous damping control of a Stewart-platform-type ankle-foot rehabilitation assist device with pneumatic actuator,\u201d J. Robot. Mechatron., Vol.25, No.6, pp. 897-905, 2013. https:\/\/doi.org\/10.20965\/jrm.2013.p0897","DOI":"10.20965\/jrm.2013.p0897"},{"key":"key-10.20965\/jrm.2024.p1550-20","doi-asserted-by":"crossref","unstructured":"Z. Hu, W. Wan, and K. Harada, \u201cDesigning a mechanical tool for robots with two-finger parallel grippers,\u201d IEEE Robotics and Automation Letters, Vol.4, No.3, pp. 2981-2988, 2019. https:\/\/doi.org\/10.1109\/LRA.2019.2924129","DOI":"10.1109\/LRA.2019.2924129"},{"key":"key-10.20965\/jrm.2024.p1550-21","doi-asserted-by":"crossref","unstructured":"A. Kobayashi, J. Kinugawa, S. Arai, and K. Kosuge, \u201cDesign and development of compactly folding parallel open-close gripper with wide stroke,\u201d 2019 IEEE\/RSJ Int. Conf. on Intelligent Robots and Systems (IROS), pp. 2408-2414, 2019. https:\/\/doi.org\/10.1109\/IROS40897.2019.8967838","DOI":"10.1109\/IROS40897.2019.8967838"}],"container-title":["Journal of Robotics and Mechatronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.fujipress.jp\/main\/wp-content\/themes\/Fujipress\/hyosetsu.php?ppno=ROBOT003600060024","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T15:07:45Z","timestamp":1734620865000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.fujipress.jp\/jrm\/rb\/robot003600061550"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,20]]},"references-count":21,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,12,20]]},"published-print":{"date-parts":[[2024,12,20]]}},"URL":"https:\/\/doi.org\/10.20965\/jrm.2024.p1550","relation":{},"ISSN":["1883-8049","0915-3942"],"issn-type":[{"value":"1883-8049","type":"electronic"},{"value":"0915-3942","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12,20]]}}}