{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:40:57Z","timestamp":1787755257075,"version":"build-2784847793"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery"],"published-print":{"date-parts":[[2017,6,21]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The available comparative studies of computer navigation-assisted and conventional knee arthroplasties have short-term follow-up periods. Therefore, the clinical benefits after long-term follow-up are not clear. The purposes of the current long-term study were to compare clinical outcomes, alignment of the knee components, prevalence of aseptic loosening of the components, implant survival, and complications of total knee arthroplasties performed with and without computer navigation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We prospectively compared the results of 162 consecutive patients (324 knees) with osteoarthritis. These patients had computer-navigated knee arthroplasty in 1 knee and knee arthroplasty without computer navigation in the other. Nine men and 153 women were enrolled in the study. At the time of the index arthroplasty, the mean age of these patients was 68.1 years (range, 49 to 81 years). The mean duration of follow-up was 12.3 years (range, 12 to 13 years). Clinical and radiographic follow-up examinations of the patients were performed at 3 months, 1 year after the operation, and every 2 or 3 years thereafter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The Knee Society knee score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and range of knee motion were not significantly different between the groups preoperatively or at 12.3 years of follow-up. Patient satisfaction at the final follow-up was not significantly different between the groups. There were no significant differences between the groups with respect to the position and loosening of the components at 12.3 years of follow-up. The Kaplan-Meier survivorship, with revision or loosening as the end point, was 100% (95% confidence interval [CI], 94% to 100%) at 12.3 years in both groups. The prevalence of anterior femoral notching was higher in the computer-navigated knee arthroplasty group (5%) than in the conventional knee arthroplasty group (0.6%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Clinical function, position, and survivorship of the components were similar between the groups. The only effect of navigation was a negative one, anterior femoral notching. However, comparison of bilateral total knee arthroplasties may dampen the differentiation regarding pain outcomes. Further, the findings of this study are specific to a single navigation and total knee system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>\n                      Therapeutic\n                      <jats:underline>Level I<\/jats:underline>\n                      . See Instructions for Authors for a complete description of levels of evidence.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.16.00791","type":"journal-article","created":{"date-parts":[[2017,6,21]],"date-time":"2017-06-21T07:08:49Z","timestamp":1498028929000},"page":"989-996","source":"Crossref","is-referenced-by-count":57,"title":["The Clinical Outcome of Computer-Navigated Compared with Conventional Knee Arthroplasty in the Same Patients"],"prefix":"10.2106","volume":"99","author":[{"given":"Young-Hoo","family":"Kim","sequence":"first","affiliation":[{"name":"Ewha Womans University School of Medicine, SeoNam Hospital, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jang-Won","family":"Park","sequence":"additional","affiliation":[{"name":"Ewha Womans University School of Medicine, MokDong Hospital, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun-Shik","family":"Kim","sequence":"additional","affiliation":[{"name":"Ewha Womans University School of Medicine, MokDong Hospital, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20230810","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/00003086-199402000-00021","article-title":"Postoperative alignment of total knee replacement. Its effect on survival","volume":"299","author":"Ritter","year":"1994","journal-title":"Clin Orthop Relat Res."},{"issue":"7","key":"bib2-20230810","first-page":"698","article-title":"A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA","volume":"22","author":"Krackow","year":"1999","journal-title":"Orthopedics."},{"issue":"5","key":"bib3-20230810","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.arth.2008.03.006","article-title":"Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty","volume":"24","author":"Weng","year":"2009","journal-title":"J Arthroplasty."},{"issue":"2","key":"bib4-20230810","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.jss.2010.05.006","article-title":"Imageless navigation system does not improve component rotational alignment in total knee arthroplasty","volume":"171","author":"Cheng","year":"2011","journal-title":"J Surg Res."},{"issue":"1","key":"bib5-20230810","doi-asserted-by":"crossref","first-page":"14","DOI":"10.2106\/JBJS.G.01700","article-title":"Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty","volume":"91","author":"Kim","year":"2009","journal-title":"J Bone Joint Surg Am."},{"issue":"5","key":"bib6-20230810","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1302\/0301-620X.86B5.14927","article-title":"Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique","volume":"86","author":"B\u00e4this","year":"2004","journal-title":"J Bone Joint Surg Br."},{"issue":"3","key":"bib7-20230810","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1302\/0301-620X.86B3.14643","article-title":"Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial","volume":"86","author":"Chauhan","year":"2004","journal-title":"J Bone Joint Surg Br."},{"issue":"2","key":"bib8-20230810","doi-asserted-by":"crossref","first-page":"236","DOI":"10.2106\/JBJS.F.00386","article-title":"A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation","volume":"89","author":"Matziolis","year":"2007","journal-title":"J Bone Joint Surg Am."},{"issue":"4","key":"bib9-20230810","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1302\/0301-620X.89B4.18878","article-title":"Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study","volume":"89","author":"Kim","year":"2007","journal-title":"J Bone Joint Surg Br."},{"issue":"22","key":"bib10-20230810","doi-asserted-by":"crossref","first-page":"2017","DOI":"10.2106\/JBJS.L.00142","article-title":"Computer-navigated versus conventional total knee arthroplasty: a prospective randomized trial","volume":"94","author":"Kim","year":"2012","journal-title":"J Bone Joint Surg Am."},{"key":"bib11-20230810","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/00003086-198911000-00004","article-title":"Rationale of the Knee Society clinical rating system","volume":"248","author":"Insall","year":"1989","journal-title":"Clin Orthop Relat Res."},{"issue":"12","key":"bib12-20230810","first-page":"1833","article-title":"Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee","volume":"15","author":"Bellamy","year":"1988","journal-title":"J Rheumatol."},{"issue":"8","key":"bib13-20230810","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1016\/S0883-5403(98)90195-4","article-title":"Assessing activity in joint replacement patients","volume":"13","author":"Zahiri","year":"1998","journal-title":"J Arthroplasty."},{"key":"bib14-20230810","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1080\/01621459.1958.10501452","article-title":"Nonparametric estimation from incomplete observations","volume":"53","author":"Kaplan","year":"1958","journal-title":"J Am Stat Assoc."},{"issue":"4","key":"bib15-20230810","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.arth.2008.02.018","article-title":"Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty","volume":"24","author":"Choong","year":"2009","journal-title":"J Arthroplasty."},{"issue":"6","key":"bib16-20230810","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1007\/s00264-008-0690-0","article-title":"Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up?","volume":"33","author":"Kamat","year":"2009","journal-title":"Int Orthop."},{"issue":"4","key":"bib17-20230810","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1007\/s00264-008-0594-z","article-title":"Functional comparison of total knee arthroplasty performed with and without a navigation system","volume":"33","author":"Seon","year":"2009","journal-title":"Int Orthop."},{"issue":"4","key":"bib18-20230810","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1302\/0301-620X.89B4.18094","article-title":"Computer navigation versus conventional total knee replacement: no difference in functional results at two years","volume":"89","author":"Spencer","year":"2007","journal-title":"J Bone Joint Surg Br."},{"issue":"12","key":"bib19-20230810","doi-asserted-by":"crossref","first-page":"3436","DOI":"10.1007\/s11999-011-2044-2","article-title":"Can computer assistance improve the clinical and functional scores in total knee arthroplasty?","volume":"469","author":"Hern\u00e1ndez-Vaquero","year":"2011","journal-title":"Clin Orthop Relat Res."},{"issue":"2","key":"bib20-20230810","doi-asserted-by":"crossref","first-page":"261","DOI":"10.2106\/JBJS.F.00601","article-title":"Navigated total knee replacement. A meta-analysis","volume":"89","author":"Bauwens","year":"2007","journal-title":"J Bone Joint Surg Am."},{"issue":"2","key":"bib21-20230810","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1055\/s-2001-15040","article-title":"[Navigation in knee endoprosthesis implantation\u2014preliminary experiences and prospective comparative study with conventional implantation technique]","volume":"139","author":"Mielke","year":"2001","journal-title":"Z Orthop Ihre Grenzgeb."},{"issue":"4","key":"bib22-20230810","doi-asserted-by":"crossref","first-page":"217","DOI":"10.3109\/10929080109146086","article-title":"Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation","volume":"6","author":"Jenny","year":"2001","journal-title":"Comput Aided Surg."},{"key":"bib23-20230810","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/01.blo.0000150564.31880.c4","article-title":"Computer-assisted navigation increases precision of component placement in total knee arthroplasty","volume":"433","author":"Haaker","year":"2005","journal-title":"Clin Orthop Relat Res."},{"issue":"8","key":"bib24-20230810","doi-asserted-by":"crossref","first-page":"861","DOI":"10.3928\/0147-7447-19900801-09","article-title":"A mathematical analysis of the effect of flexion and rotation on apparent varus\/valgus alignment at the knee","volume":"13","author":"Krackow","year":"1990","journal-title":"Orthopedics."},{"issue":"3","key":"bib25-20230810","doi-asserted-by":"crossref","first-page":"S72","DOI":"10.3928\/01477447-20160509-21","article-title":"10-year survival of navigated versus conventional TKAs: a retrospective study","volume":"39","author":"Baumbach","year":"2016","journal-title":"Orthopedics."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00004623-201706210-00002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:40:12Z","timestamp":1787751612000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00004623-201706210-00002"}},"subtitle":["A Prospective, Randomized, Double-Blind, Long-Term Study"],"short-title":[],"issued":{"date-parts":[[2017,6,21]]},"references-count":25,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.16.00791","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,21]]}}}