{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:42:30Z","timestamp":1787755350234,"version":"build-2784847793"},"reference-count":66,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,3,3]]},"abstract":"<jats:title>Abstract:<\/jats:title>\n                  <jats:p>Adverse local tissue reactions (ALTRs) were initially reported as complications associated with metal-on-metal (MoM) bearings; however, there is increasing concern regarding the occurrence of adverse local tissue reactions from mechanically assisted crevice corrosion (MACC) at the femoral head-neck junction or between other modular junctions of the implant containing cobalt chromium parts in patients with metal-on-polyethylene (MoP) bearings. ALTR due to MACC at the head-neck junction has primarily been reported in association with cobalt chromium alloy femoral heads. As pain following total hip arthroplasty may have various intrinsic and extrinsic causes, a systematic approach to evaluation (risk stratification algorithm) based on the currently available data is recommended to optimize patient management. Evaluation should begin by ruling out common causes of pain, including component loosening and periprosthetic joint infection. While specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful modalities in evaluating for ALTRs, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. There should be a low threshold to perform a systematic evaluation for ALTR due to MACC in patients with metal-on-polyethylene total hip arthroplasty as early recognition and diagnosis is critical, as delays in appropriate treatment initiation may result in soft-tissue damage, which complicates surgical treatment and is associated with a higher risk of complications and poorer patient outcomes.<\/jats:p>","DOI":"10.2106\/jbjs.20.01837","type":"journal-article","created":{"date-parts":[[2021,1,13]],"date-time":"2021-01-13T09:32:41Z","timestamp":1610530361000},"page":"e18","source":"Crossref","is-referenced-by-count":14,"title":["Risk Stratification Algorithm for Management of Head-Neck Taper Tribocorrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty"],"prefix":"10.2106","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6744-3864","authenticated-orcid":false,"given":"Young-Min","family":"Kwon","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2913-7513","authenticated-orcid":false,"given":"Craig J.","family":"Della Valle","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8562-1329","authenticated-orcid":false,"given":"Adolph V.","family":"Lombardi","sequence":"additional","affiliation":[{"name":"Joint Implant Surgeons, Inc., The Ohio State University, New Albany, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6257-6644","authenticated-orcid":false,"given":"Donald S.","family":"Garbuz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of British Columbia, Vancouver, British Columbia, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1422-0306","authenticated-orcid":false,"given":"Daniel J.","family":"Berry","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3902-7334","authenticated-orcid":false,"given":"Joshua J.","family":"Jacobs","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,1,7]]},"reference":[{"issue":"9","key":"bib1-20231204","article-title":"Modular versus nonmodular femoral necks for primary total hip arthroplasty","volume":"44","author":"Carothers","year":"2015","journal-title":"Am J Orthop."},{"issue":"3","key":"bib2-20231204","doi-asserted-by":"crossref","DOI":"10.1302\/0301-620X.92B3.23281","article-title":"Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours","volume":"92","author":"Kwon","year":"2010","journal-title":"J Bone Joint Surg Br."},{"issue":"5","key":"bib3-20231204","doi-asserted-by":"crossref","DOI":"10.1007\/s00264-016-3305-1","article-title":"Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation","volume":"41","author":"Liow","year":"2017","journal-title":"Int Orthop."},{"issue":"8","key":"bib4-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2018.03.061","article-title":"The fate of elevated metal ion levels after revision surgery for head-neck taper corrosion in patients with metal-on-polyethylene total hip arthroplasty","volume":"33","author":"Kwon","year":"2018","journal-title":"J Arthroplasty."},{"issue":"9","key":"bib5-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2018.04.007","article-title":"Sensitivity and specificity of metal ion level in predicting adverse local tissue reactions due to head-neck taper corrosion in primary metal-on-polyethylene total hip arthroplasty","volume":"33","author":"Kwon","year":"2018","journal-title":"J Arthroplasty."},{"issue":"5","key":"bib6-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.11.046","article-title":"MRI, retrieval analysis, and histologic evaluation of adverse local tissue reaction in metal-on-polyethylene total hip arthroplasty","volume":"32","author":"Nodzo","year":"2017","journal-title":"J Arthroplasty."},{"issue":"10","key":"bib7-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2018.05.046","article-title":"Risk factors associated with early complications of revision surgery for head-neck taper corrosion in metal-on-polyethylene total hip arthroplasty","volume":"33","author":"Kwon","year":"2018","journal-title":"J Arthroplasty."},{"issue":"18","key":"bib8-20231204","article-title":"Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty","volume":"94","author":"Cooper","year":"2012","journal-title":"J Bone Joint Surg Am."},{"issue":"10","key":"bib9-20231204","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.L.01042","article-title":"Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck","volume":"95","author":"Cooper","year":"2013","journal-title":"J Bone Joint Surg Am."},{"issue":"6S","key":"bib10-20231204","article-title":"Outcome of re-revision surgery for adverse local tissue reaction in metal-on-polyethylene and metal-on-metal total hip arthroplasty","volume":"35","author":"Bonner","year":"2020","journal-title":"J Arthroplasty."},{"issue":"20","key":"bib11-20231204","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.15.01325","article-title":"Asymptomatic pseudotumors in patients with taper corrosion of a dual-taper modular femoral stem: MARS-MRI and metal ion study","volume":"98","author":"Kwon","year":"2016","journal-title":"J Bone Joint Surg Am."},{"issue":"7","key":"bib12-20231204","doi-asserted-by":"crossref","DOI":"10.1002\/jbm.a.36057","article-title":"Adverse reactions to metal on polyethylene implants: highly destructive lesions related to elevated concentration of cobalt and chromium in synovial fluid","volume":"105","author":"Eltit","year":"2017","journal-title":"J Biomed Mater Res A."},{"issue":"2","key":"bib13-20231204","doi-asserted-by":"crossref","DOI":"10.2106\/00004623-199802000-00015","article-title":"Corrosion of metal orthopaedic implants","volume":"80","author":"Jacobs","year":"1998","journal-title":"J Bone Joint Surg Am."},{"issue":"7","key":"bib14-20231204","article-title":"Corrosion at the head-neck junction: why is this happening now?","volume":"31","author":"Jacobs","year":"2016","journal-title":"J Arthroplasty."},{"issue":"7","key":"bib15-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.02.082","article-title":"Diagnosis and treatment of adverse local tissue reactions at the head-neck junction","volume":"31","author":"Cooper","year":"2016","journal-title":"J Arthroplasty."},{"issue":"7","key":"bib16-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2015.02.019","article-title":"A high prevalence of corrosion at the head-neck taper with contemporary Zimmer non-cemented femoral hip components","volume":"30","author":"McGrory","year":"2015","journal-title":"J Arthroplasty."},{"issue":"9S","key":"bib17-20231204","article-title":"Serum metal levels for diagnosis of adverse local tissue reactions secondary to corrosion in metal-on-polyethylene total hip arthroplasty","volume":"32","author":"Fillingham","year":"2017","journal-title":"J Arthroplasty."},{"issue":"1","key":"bib18-20231204","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.2106\/JBJS.M.00160","article-title":"Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society","volume":"96","author":"Kwon","year":"2014","journal-title":"J Bone Joint Surg Am."},{"issue":"11","key":"bib19-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2014.07.029","article-title":"Risk stratification algorithm for management of patients with dual modular taper total hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society","volume":"29","author":"Kwon","year":"2014","journal-title":"J Arthroplasty."},{"issue":"3","key":"bib20-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2017.10.010","article-title":"Fretting and corrosion damage in retrieved metal-on-polyethylene modular total hip arthroplasty systems: what is the importance of femoral head size?","volume":"33","author":"Siljander","year":"2018","journal-title":"J Arthroplasty."},{"issue":"6","key":"bib21-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2012.10.017","article-title":"The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints","volume":"28","author":"Dyrkacz","year":"2013","journal-title":"J Arthroplasty."},{"issue":"12","key":"bib22-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.05.047","article-title":"Increased femoral head offset is associated with elevated metal ions in asymptomatic patients with metal-on-polyethylene total hip arthroplasty","volume":"31","author":"Martin","year":"2016","journal-title":"J Arthroplasty."},{"issue":"7","key":"bib23-20231204","doi-asserted-by":"crossref","DOI":"10.1302\/0301-620X.97B7.35149","article-title":"Taperosis: does head length affect fretting and corrosion in total hip arthroplasty?","volume":"97-B","author":"Del Balso","year":"2015","journal-title":"Bone Joint J."},{"issue":"2","key":"bib24-20231204","doi-asserted-by":"crossref","DOI":"10.5435\/JAAOS-D-16-00352","article-title":"Trunnion corrosion in metal-on-polyethylene total hip arthroplasty: a case series","volume":"25","author":"Raju","year":"2017","journal-title":"J Am Acad Orthop Surg."},{"issue":"2","key":"bib25-20231204","doi-asserted-by":"crossref","DOI":"10.1007\/s11999-015-4468-6","article-title":"Otto Aufranc Award: large heads do not increase damage at the head-neck taper of metal-on-polyethylene total hip arthroplasties","volume":"474","author":"Triantafyllopoulos","year":"2016","journal-title":"Clin Orthop Relat Res."},{"issue":"9","key":"bib26-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.02.079","article-title":"Flexural rigidity, taper angle, and contact length affect fretting of the femoral stem trunnion in total hip arthroplasty","volume":"31","author":"Kao","year":"2016","journal-title":"J Arthroplasty."},{"key":"bib27-20231204","doi-asserted-by":"crossref","DOI":"10.1097\/00003086-200208000-00018","article-title":"A multicenter retrieval study of the taper interfaces of modular hip prostheses","volume":"401","author":"Goldberg","year":"2002","journal-title":"Clin Orthop Relat Res."},{"issue":"5","key":"bib28-20231204","doi-asserted-by":"crossref","DOI":"10.1302\/0301-620X.98B5.35592","article-title":"Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions","volume":"98-B","author":"Osman","year":"2016","journal-title":"Bone Joint J."},{"issue":"1","key":"bib29-20231204","article-title":"Trunnion corrosion: what surgeons need to know in 2018","volume":"100-B","author":"Berstock","year":"2018","journal-title":"Bone Joint J."},{"issue":"7","key":"bib30-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.jbiomech.2014.02.035","article-title":"Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters","volume":"47","author":"Donaldson","year":"2014","journal-title":"J Biomech."},{"issue":"10","key":"bib31-20231204","article-title":"Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis","volume":"93","author":"JU","year":"2011","journal-title":"J Bone Joint Surg Br."},{"issue":"12","key":"bib32-20231204","doi-asserted-by":"crossref","DOI":"10.1007\/s11999-014-3965-3","article-title":"Modern trunnions are more flexible: a mechanical analysis of THA taper designs","volume":"472","author":"Porter","year":"2014","journal-title":"Clin Orthop Relat Res."},{"issue":"8","key":"bib33-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2013.02.009","article-title":"Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements","volume":"28","author":"Cook","year":"2013","journal-title":"J Arthroplasty."},{"issue":"12","key":"bib34-20231204","doi-asserted-by":"crossref","DOI":"10.1002\/jbm.820271210","article-title":"In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling","volume":"27","author":"Gilbert","year":"1993","journal-title":"J Biomed Mater Res."},{"issue":"6","key":"bib35-20231204","doi-asserted-by":"crossref","DOI":"10.1097\/CORR.0000000000001277","article-title":"What is the risk of THA revision for ARMD in patients with non-metal-on-metal bearings? A study from the Australian National Joint Replacement Registry","volume":"478","author":"de Steiger","year":"2020","journal-title":"Clin Orthop Relat Res."},{"issue":"7","key":"bib36-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2015.02.031","article-title":"Effect of taper design on trunnionosis in metal on polyethylene total hip arthroplasty","volume":"30","author":"Tan","year":"2015","journal-title":"J Arthroplasty."},{"issue":"10","key":"bib37-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.03.009","article-title":"Trunnionosis: does head size affect fretting and corrosion in total hip arthroplasty?","volume":"31","author":"Del Balso","year":"2016","journal-title":"J Arthroplasty."},{"issue":"3","key":"bib38-20231204","doi-asserted-by":"crossref","DOI":"10.1177\/0954411911431397","article-title":"Edge loading in metal-on-metal hips: low clearance is a new risk factor","volume":"226","author":"Underwood","year":"2012","journal-title":"Proc Inst Mech Eng H."},{"issue":"12","key":"bib39-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2020.06.058","article-title":"Sensitivity and specificity of serum and synovial fluid markers in diagnosis of infection in head-neck taper corrosion of metal-on-polyethylene total hip arthroplasty","volume":"35","author":"Kwon","year":"2020","journal-title":"J Arthroplasty."},{"issue":"9","key":"bib40-20231204","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.G.01255","article-title":"Perioperative testing for joint infection in patients undergoing revision total hip arthroplasty","volume":"90","author":"Schinsky","year":"2008","journal-title":"J Bone Joint Surg Am."},{"issue":"6","key":"bib41-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2018.01.007","article-title":"The alpha-defensin test for diagnosing periprosthetic joint infection in the setting of an adverse local tissue reaction secondary to a failed metal-on-metal bearing or corrosion at the head-neck junction","volume":"33","author":"Okroj","year":"2018","journal-title":"J Arthroplasty."},{"issue":"9","key":"bib42-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2020.04.024","article-title":"Adverse local tissue reaction due to mechanically assisted crevice corrosion presenting as late instability following metal-on-polyethylene total hip arthroplasty","volume":"35","author":"Hannon","year":"2020","journal-title":"J Arthroplasty."},{"issue":"4","key":"bib43-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2010.05.030","article-title":"\u201cAsymptomatic\u201d pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study","volume":"26","author":"Kwon","year":"2011","journal-title":"J Arthroplasty."},{"issue":"10","key":"bib44-20231204","doi-asserted-by":"crossref","DOI":"10.1302\/0301-620X.93B10.26249","article-title":"Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement","volume":"93","author":"Hart","year":"2011","journal-title":"J Bone Joint Surg Br."},{"issue":"8","key":"bib45-20231204","article-title":"A consensus paper on metal ions in metal-on-metal hip arthroplasties","volume":"19","author":"MacDonald","year":"2004","journal-title":"J Arthroplasty."},{"issue":"7","key":"bib46-20231204","doi-asserted-by":"crossref","DOI":"10.1302\/0301-620X.94B7.29122","article-title":"Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation","volume":"94","author":"Gill","year":"2012","journal-title":"J Bone Joint Surg Br."},{"issue":"3","key":"bib47-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.08.040","article-title":"Sensitivity and specificity of metal ion levels in predicting \u201cpseudotumors\u201d due to taper corrosion in patients with dual taper modular total hip arthroplasty","volume":"32","author":"Kwon","year":"2017","journal-title":"J Arthroplasty."},{"issue":"7","key":"bib48-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2013.01.018","article-title":"Taper corrosion in modular hip prostheses: analysis of serum metal ions in 19 patients","volume":"28","author":"Vundelinckx","year":"2013","journal-title":"J Arthroplasty."},{"issue":"8","key":"bib49-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2012.03.020","article-title":"Are metal ion levels a useful trigger for surgical intervention?","volume":"27","author":"Griffin","year":"2012","journal-title":"J Arthroplasty."},{"issue":"8","key":"bib50-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2012.03.029","article-title":"Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients","volume":"27","author":"Kwon","year":"2012","journal-title":"J Arthroplasty."},{"issue":"5","key":"bib51-20231204","doi-asserted-by":"crossref","DOI":"10.2106\/00004623-199905000-00008","article-title":"Prospective analysis of preoperative and intraoperative investigations for the diagnosis of infection at the sites of two hundred and two revision total hip arthroplasties","volume":"81","author":"Spangehl","year":"1999","journal-title":"J Bone Joint Surg Am."},{"issue":"2","key":"bib52-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.ocl.2010.12.006","article-title":"Imaging of metal-on-metal hip resurfacing [viii.]","volume":"42","author":"Hayter","year":"2011","journal-title":"Orthop Clin North Am."},{"issue":"4","key":"bib53-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2014.02.007","article-title":"Cross-sectional imaging in evaluation of soft tissue reactions secondary to metal debris","volume":"29","author":"Kwon","year":"2014","journal-title":"J Arthroplasty."},{"issue":"3","key":"bib54-20231204","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.16.17789","article-title":"Advanced MRI techniques for the hip joint: focus on the postoperative hip","volume":"209","author":"Berkowitz","year":"2017","journal-title":"AJR Am J Roentgenol."},{"issue":"4","key":"bib55-20231204","doi-asserted-by":"crossref","DOI":"10.1148\/rg.344140010","article-title":"MR imaging of hip arthroplasty implants","volume":"34","author":"Fritz","year":"2014","journal-title":"Radiographics."},{"issue":"3","key":"bib56-20231204","doi-asserted-by":"crossref","DOI":"10.1002\/jmri.23991","article-title":"Quantifying image distortion of orthopedic materials in magnetic resonance imaging","volume":"38","author":"Koff","year":"2013","journal-title":"J Magn Reson Imaging."},{"issue":"3","key":"bib57-20231204","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.11.7364","article-title":"Metal-induced artifacts in MRI","volume":"197","author":"Hargreaves","year":"2011","journal-title":"AJR Am J Roentgenol."},{"issue":"1","key":"bib58-20231204","doi-asserted-by":"crossref","DOI":"10.1148\/radiol.2015141967","article-title":"MR imaging of adverse local tissue reactions around Rejuvenate modular dual-taper stems","volume":"277","author":"Burge","year":"2015","journal-title":"Radiology."},{"issue":"4","key":"bib59-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2015.10.041","article-title":"Short-term outcomes and complications after Rejuvenate modular total hip arthroplasty revision","volume":"31","author":"Barlow","year":"2016","journal-title":"J Arthroplasty."},{"issue":"1","key":"bib60-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2013.08.026","article-title":"Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant","volume":"29","author":"Pivec","year":"2014","journal-title":"J Arthroplasty."},{"issue":"9","key":"bib61-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2014.03.055","article-title":"Do you have to remove a corroded femoral stem?","volume":"29","author":"Goyal","year":"2014","journal-title":"J Arthroplasty."},{"issue":"12","key":"bib62-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2020.06.043","article-title":"Outcome of dual mobility constructs for adverse local tissue reaction associated abductor deficiency in revision total hip arthroplasty","volume":"35","author":"Klemt","year":"2020","journal-title":"J Arthroplasty."},{"issue":"1","key":"bib63-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2015.07.035","article-title":"Serum metal ion levels following total hip arthroplasty with modular dual mobility components","volume":"31","author":"Matsen Ko","year":"2016","journal-title":"J Arthroplasty."},{"issue":"5","key":"bib64-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2016.12.012","article-title":"Metal ion levels in young, active patients receiving a modular, dual mobility total hip arthroplasty","volume":"32","author":"Nam","year":"2017","journal-title":"J Arthroplasty."},{"issue":"6","key":"bib65-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2019.02.008","article-title":"Fretting and corrosion damage of retrieved dual-mobility total hip arthroplasty systems","volume":"34","author":"Lombardo","year":"2019","journal-title":"J Arthroplasty."},{"issue":"1","key":"bib66-20231204","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2015.07.039","article-title":"Diagnosis and management of adverse local tissue reactions secondary to corrosion at the head-neck junction in patients with metal on polyethylene bearings","volume":"31","author":"Plummer","year":"2016","journal-title":"J Arthroplasty."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.20.01837","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:41:40Z","timestamp":1787751700000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.20.01837"}},"subtitle":["Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society"],"short-title":[],"issued":{"date-parts":[[2021,1,7]]},"references-count":66,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.20.01837","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,7]]}}}