{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:40:10Z","timestamp":1787755210803,"version":"build-2784847793"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5,18]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The purpose of the present study was to determine specific fluoroscopic views of the femoral neck to accurately identify partially extraosseous (\u201cin-out-in\u201d; IOI) placement of the posterosuperior screw for fixation of femoral neck fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A 3.2-mm guide pin was placed in the posterosuperior aspect of 2 synthetic femur models: 1 entirely intraosseous and 1 IOI. Sequential fluoroscopic images were made at 5\u00b0 intervals in order to identify which fluoroscopic projections identified IOI guide pin placement. These images were utilized to inform screw placement and assessment in the second phase of the study, which involved the use of cadaveric specimens. In Phase II, the posterosuperior screw of the inverted triangle was placed in 10 cadaveric specimens with use of a standard posteroanterior fluoroscopic view and 1 of 2 lateral views, either (1) neck in line with the shaft, i.e., 0\u00b0 lateral; or (2) a \u221215\u00b0 rollunder view. The final fluoroscopic views (i.e., the posteroanterior and multiple lateral and oblique views) were randomized and blinded for review by 10 orthopaedic residents and 5 attending orthopaedic traumatologists. Specimens were stripped of soft tissue and inspected for screw perforation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Overall accuracy of respondents was 68.8%, with no difference between the attending traumatologists (71.8%) and resident surgeons (67.4%; p = 0.173). Interobserver reliability was moderate (\u03ba = 0.496). Dissection identified that 4 (40%) of 10 screws were extraosseous. All of the extraosseous screws were placed with use of the 0\u00b0 lateral view. The \u221215\u00b0 rollunder lateral view was the most sensitive (81.7%) and specific (92.2%) view for identifying IOI screw placement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Surgeons often utilize the standard posteroanterior and 0\u00b0 lateral fluoroscopic views to safely place screws; however, many of these screws are IOI. The addition of a \u221215\u00b0 rollunder lateral view significantly improved identification of IOI screws in the posterosuperior femoral neck. Unidentified IOI screw placement may result in damage to the blood supply of the femoral head.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.21.00959","type":"journal-article","created":{"date-parts":[[2022,2,15]],"date-time":"2022-02-15T15:07:59Z","timestamp":1644937679000},"page":"889-895","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["A Novel Fluoroscopic View for Improved Assessment of the Safety of the Posterosuperior Screw in Femoral Neck Fracture Fixation"],"prefix":"10.2106","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7485-3343","authenticated-orcid":false,"given":"E. Bailey","family":"Terhune","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9707-3609","authenticated-orcid":false,"given":"Evan M.","family":"Polce","sequence":"additional","affiliation":[{"name":"School of Medicine, University of Wisconsin, Madison, Wisconsin"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1851-1741","authenticated-orcid":false,"given":"Joel C.","family":"Williams","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,2,15]]},"reference":[{"issue":"1","key":"bib1-20250430","doi-asserted-by":"crossref","first-page":"61","DOI":"10.2106\/JBJS.K.01081","article-title":"Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration","volume":"95","author":"Yang","year":"2013","journal-title":"J Bone Joint Surg Am."},{"issue":"4","key":"bib2-20250430","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/j.injury.2020.01.032","article-title":"Posterior fully threaded positioning screw prevents femoral neck collapse in Garden I or II femoral neck fractures","volume":"51","author":"Shin","year":"2020","journal-title":"Injury."},{"issue":"2","key":"bib3-20250430","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/S0020-1383(03)00059-7","article-title":"Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study","volume":"35","author":"Selvan","year":"2004","journal-title":"Injury."},{"issue":"10","key":"bib4-20250430","doi-asserted-by":"crossref","first-page":"625","DOI":"10.3928\/01477447-20151002-05","article-title":"Optimizing Stability in Femoral Neck Fracture Fixation","volume":"38","author":"Ye","year":"2015","journal-title":"Orthopedics."},{"issue":"Suppl 1","key":"bib5-20250430","doi-asserted-by":"crossref","first-page":"S27","DOI":"10.1097\/BOT.0000000000001365","article-title":"Biomechanics of Femoral Neck Fractures and Implications for Fixation","volume":"33","author":"Augat","year":"2019","journal-title":"J Orthop Trauma."},{"issue":"3","key":"bib6-20250430","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1007\/s00590-020-02796-y","article-title":"Modified radiographic views to prevent the anterosuperior and posterosuperior bony violation during screw fixation of femoral neck fractures","volume":"31","author":"Kumar","year":"2021","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"8","key":"bib7-20250430","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1007\/s00590-020-02717-z","article-title":"High incidence of \u201cin-out-in\u201d posterosuperior screws after cannulated screw fixation of femoral neck fractures","volume":"30","author":"Yuan","year":"2020","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"7","key":"bib8-20250430","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/BOT.0000000000001461","article-title":"Is the Cranial and Posterior Screw of the \u201cInverted Triangle\u201d Configuration for Femoral Neck Fractures Safe?","volume":"33","author":"Hoffmann","year":"2019","journal-title":"J Orthop Trauma."},{"issue":"3","key":"bib9-20250430","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1097\/BOT.0000000000001914","article-title":"Radiographic quantification of safe zones for screw placement in the femoral neck: a computed tomography-based analysis","volume":"35","author":"Kumar","year":"2021","journal-title":"J Orthop Trauma."},{"issue":"6","key":"bib10-20250430","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1007\/s00590-020-02668-5","article-title":"Sequential fluoroscopic rollover images reliably identify \u201cin-out-in\u201d posterosuperior screws during percutaneous fixation of femoral neck fractures","volume":"30","author":"Aibinder","year":"2020","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"10","key":"bib12-20250430","doi-asserted-by":"crossref","first-page":"e885","DOI":"10.3928\/01477447-20140924-54","article-title":"Multiple radiographic projections in detecting intra-articular screw penetration during fixation of femoral neck fractures","volume":"37","author":"Zhang","year":"2014","journal-title":"Orthopedics."},{"issue":"5","key":"bib13-20250430","doi-asserted-by":"crossref","first-page":"e178","DOI":"10.1097\/BOT.0000000000000239","article-title":"The femoral neck safe zone: a radiographic simulation study to prevent cortical perforation with multiple screw insertion","volume":"29","author":"Zhang","year":"2015","journal-title":"J Orthop Trauma."},{"issue":"2","key":"bib14-20250430","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.injury.2010.10.005","article-title":"Effect of integrity of the posterior cortex in displaced femoral neck fractures on outcome after surgical fixation in young adults","volume":"42","author":"Huang","year":"2011","journal-title":"Injury."},{"issue":"8","key":"bib15-20250430","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.2106\/00004623-200408000-00015","article-title":"Operative treatment of femoral neck fractures in patients between the ages of fifteen and fifty years","volume":"86","author":"Haidukewych","year":"2004","journal-title":"J Bone Joint Surg Am."},{"issue":"3","key":"bib16-20250430","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.injury.2014.11.015","article-title":"Gaps and opportunities in the management of the young femoral neck fracture","volume":"46","author":"Della Rocca","year":"2015","journal-title":"Injury."},{"issue":"6","key":"bib17-20250430","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1302\/0301-620X.93B6.26432","article-title":"Fixation of intracapsular fractures of the femoral neck in young patients: risk factors for failure","volume":"93","author":"Duckworth","year":"2011","journal-title":"J Bone Joint Surg Br."},{"issue":"2","key":"bib18-20250430","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.jor.2014.01.001","article-title":"Predictors of early failure in young patients with displaced femoral neck fractures","volume":"12","author":"Gardner","year":"2014","journal-title":"J Orthop."},{"issue":"5","key":"bib19-20250430","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1302\/0301-620X.82B5.0820679","article-title":"Anatomy of the medial femoral circumflex artery and its surgical implications","volume":"82","author":"Gautier","year":"2000","journal-title":"J Bone Joint Surg Br."},{"issue":"12","key":"bib20-20250430","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1097\/BOT.0000000000001846","article-title":"Posterior Inferior Comminution Significantly Influences Torque to Failure in Vertically Oriented Femoral Neck Fractures: A Biomechanical Study","volume":"34","author":"Wright","year":"2020","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.21.00959","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:39:20Z","timestamp":1787751560000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.21.00959"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,15]]},"references-count":19,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.21.00959","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,15]]}}}