{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T18:05:44Z","timestamp":1789581944090,"version":"build-2803163510"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Focal cartilage lesions (FCLs) of the knee can cause pain and dysfunction. Focal resurfacing with mini-prostheses offers an alternative to biological treatments, yet current clinical options remain limited. This preliminary study investigated a novel mini-prosthesis in a porcine model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A Ti6Al4V mini-prosthesis with a carbon-based nano-multilayer film (NMF)-coated articular surface and a 3D-printed porous stem was developed (NMF@3D-Ti). Two comparators were included in the study: an NMF-coated Ti articular surface with a hydroxyapatite (HA)-coated stem (NMF@HA-Ti) and a cobalt-chromium (CoCr) prosthesis with a polished articular surface and an HA-coated stem (HA-CoCr). Twenty-five Bama pigs underwent bilateral medial femoral condyle surgery and were divided into 5 treatment groups: NMF@3D-Ti, NMF@HA-Ti, HA-CoCr, microfracture (MF), and sham. All animals were killed at 24 weeks. Evaluations included radiography, biocompatibility, overall joint condition, gross and histological analysis of opposing and adjacent cartilage, gene expression analysis in opposing cartilage, synovial inflammatory cytokines, and osseointegration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Radiographs revealed no implant-related complications, and biocompatibility was confirmed. The HA-CoCr group had the most severe opposing-cartilage damage, with significantly worse macroscopic and microscopic scores, upregulated catabolic gene expression, and elevated synovial inflammatory cytokines compared with all other groups (all p &lt; 0.05), along with disrupted collagen organization. The NMF@3D-Ti and NMF@HA-Ti groups were comparable with the sham group across all cartilage assessments. The MF group showed intermediate histological and gene expression changes in the opposing cartilage. Furthermore, the NMF@3D-Ti group demonstrated superior osseointegration, with significantly greater bone volume\/total volume, bone mineral density, and bone-implant contact than the other implant groups (all p &lt; 0.05), and no evidence of stress-shielding in the comparison with the sham group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>At 24 weeks, the NMF@3D-Ti mini-prosthesis exhibited favorable biocompatibility and robust osseointegration, and achieved superior cartilage protection compared with both the CoCr mini-prosthesis and MF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>This mini-prosthesis provides a joint-preserving approach that may be a valuable addition to the current armamentarium, enriching the stepped-care algorithm for osteoarthritis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.26.00538","type":"journal-article","created":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T18:00:33Z","timestamp":1789581633000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Mini-Prosthesis with a Nano-Multilayer Film-Coated Surface and 3D-Printed Porous Stem for Focal Cartilage Lesions"],"prefix":"10.2106","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2750-9670","authenticated-orcid":false,"given":"Guangqian","family":"Shang","sequence":"first","affiliation":[{"name":"School of Medicine, Nankai University, Tianjin, People\u2019s Republic of China"},{"name":"Senior Department of Orthopedics, Chinese PLA General Hospital, Beijing, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-6042-2115","authenticated-orcid":false,"given":"Yuhao","family":"Mu","sequence":"additional","affiliation":[{"name":"School of Medicine, Nankai University, Tianjin, People\u2019s Republic of China"},{"name":"Senior Department of Orthopedics, Chinese PLA General Hospital, Beijing, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9779-2811","authenticated-orcid":false,"given":"Ketao","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Sports Medicine, Beijing Chaoyang Hospital, Beijing, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-4835-9458","authenticated-orcid":false,"given":"Zheng","family":"Guo","sequence":"additional","affiliation":[{"name":"Senior Department of Orthopedics, Chinese PLA General Hospital, Beijing, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-3890-2919","authenticated-orcid":false,"given":"Zhongli","family":"Li","sequence":"additional","affiliation":[{"name":"School of Medicine, Nankai University, Tianjin, People\u2019s Republic of China"},{"name":"Senior Department of Orthopedics, Chinese PLA General Hospital, Beijing, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5565-7582","authenticated-orcid":false,"given":"Ji","family":"Li","sequence":"additional","affiliation":[{"name":"Senior Department of Orthopedics, Chinese PLA General Hospital, Beijing, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,16]]},"reference":[{"key":"bib1-20260916","doi-asserted-by":"crossref","first-page":"6275","DOI":"10.2147\/IJN.S382737","article-title":"Advances in the Treatment of Partial-Thickness Cartilage Defect","volume":"17","author":"Sun","year":"2022","journal-title":"Int J Nanomedicine."},{"issue":"11","key":"bib2-20260916","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1016\/j.arthro.2006.06.020","article-title":"Is microfracture of chondral defects in the knee associated with different results in patients aged 40 years or younger?","volume":"22","author":"Kreuz","year":"2006","journal-title":"Arthroscopy."},{"issue":"3","key":"bib3-20260916","doi-asserted-by":"crossref","first-page":"282","DOI":"10.4055\/cios.2019.11.3.282","article-title":"Clinical and Radiological Changes after Microfracture of Knee Chondral Lesions in Middle-Aged Asian Patients","volume":"11","author":"Kim","year":"2019","journal-title":"Clin Orthop Surg."},{"issue":"Suppl 1","key":"bib4-20260916","doi-asserted-by":"crossref","first-page":"58S","DOI":"10.1177\/0363546509349765","article-title":"Patient profiling in cartilage regeneration: prognostic factors determining success of treatment for cartilage defects","volume":"37","author":"de Windt","year":"2009","journal-title":"Am J Sports Med."},{"issue":"10","key":"bib5-20260916","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.2106\/00004623-200710000-00002","article-title":"A randomized trial comparing autologous chondrocyte implantation with microfracture. Findings at five years","volume":"89","author":"Knutsen","year":"2007","journal-title":"J Bone Joint Surg Am."},{"issue":"2","key":"bib6-20260916","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1111\/os.13949","article-title":"Osteochondral Regeneration in the Knee Joint with Autologous Peripheral Blood Stem Cells plus Hyaluronic Acid after Arthroscopic Subchondral Drilling: Report of Five Cases","volume":"16","author":"Saw","year":"2024","journal-title":"Orthop Surg."},{"issue":"13","key":"bib7-20260916","doi-asserted-by":"crossref","first-page":"3069","DOI":"10.1177\/0363546517717679","article-title":"Clinical and Radiological Regeneration of Large and Deep Osteochondral Defects of the Knee by Bone Augmentation Combined With Matrix-Guided Autologous Chondrocyte Transplantation","volume":"45","author":"Zellner","year":"2017","journal-title":"Am J Sports Med."},{"issue":"6","key":"bib8-20260916","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.1007\/s00167-020-06230-y","article-title":"Matrix-assisted chondrocyte transplantation with bone grafting for knee osteochondritis dissecans: stable results at 12 years","volume":"29","author":"Andriolo","year":"2021","journal-title":"Knee Surg Sports Traumatol Arthrosc."},{"issue":"9","key":"bib9-20260916","doi-asserted-by":"crossref","first-page":"4027","DOI":"10.1007\/s00167-023-07450-8","article-title":"High degree of consensus amongst an expert panel regarding focal resurfacing of chondral and osteochondral lesions of the femur with mini-implants","volume":"31","author":"Becher","year":"2023","journal-title":"Knee Surg Sports Traumatol Arthrosc."},{"issue":"8","key":"bib10-20260916","doi-asserted-by":"crossref","first-page":"728","DOI":"10.2106\/JBJS.20.01086","article-title":"Incidence of Osteolysis and Aseptic Loosening Following Metal-on-Highly Cross-Linked Polyethylene Hip Arthroplasty: A Systematic Review of Studies with Up to 15-Year Follow-up","volume":"103","author":"Prock-Gibbs","year":"2021","journal-title":"J Bone Joint Surg Am."},{"issue":"3","key":"bib11-20260916","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.joca.2009.10.009","article-title":"Cartilage degeneration in the goat knee caused by treating localized cartilage defects with metal implants","volume":"18","author":"Custers","year":"2010","journal-title":"Osteoarthritis Cartilage."},{"issue":"3","key":"bib12-20260916","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.joca.2015.09.009","article-title":"Treatment of full thickness focal cartilage lesions with a metallic resurfacing implant in a sheep animal model, 1 year evaluation","volume":"24","author":"Martinez-Carranza","year":"2016","journal-title":"Osteoarthritis Cartilage."},{"issue":"1","key":"bib13-20260916","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1002\/jor.20709","article-title":"Cartilage damage caused by metal implants applied for the treatment of established localized cartilage defects in a rabbit model","volume":"27","author":"Custers","year":"2009","journal-title":"J Orthop Res."},{"issue":"1_suppl","key":"bib14-20260916","doi-asserted-by":"crossref","first-page":"1718S","DOI":"10.1177\/1947603519894732","article-title":"HemiCAP Knee Implants: Mid- to Long-Term Results","volume":"13","author":"Laursen","year":"2021","journal-title":"Cartilage."},{"issue":"1","key":"bib15-20260916","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s00590-020-02746-8","article-title":"Focal inlay resurfacing for full-thickness chondral defects of the femoral medial condyle may delay the progression to varus deformity","volume":"31","author":"Cases","year":"2021","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"2","key":"bib16-20260916","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1007\/s00402-019-03305-5","article-title":"Focal metallic inlay resurfacing prosthesis in articular cartilage defects: short-term results of 118 patients and 2 different implants","volume":"140","author":"\u00c7epni","year":"2020","journal-title":"Arch Orthop Trauma Surg."},{"issue":"1","key":"bib17-20260916","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1515\/med-2022-0494","article-title":"Does the use of 3D-printed cones give a chance to postpone the use of megaprostheses in patients with large bone defects in the knee joint?","volume":"17","author":"Kotrych","year":"2022","journal-title":"Open Med (Wars)."},{"key":"bib18-20260916","doi-asserted-by":"crossref","first-page":"1428446","DOI":"10.3389\/fbioe.2024.1428446","article-title":"Design and validation of a novel 3D-printed glenohumeral fusion prosthesis for the reconstruction of proximal humerus bone defects: a biomechanical study","volume":"12","author":"Lin","year":"2024","journal-title":"Front Bioeng Biotechnol."},{"issue":"1","key":"bib19-20260916","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1186\/s13018-023-03612-z","article-title":"Design and performance analysis of 3D-printed stiffness gradient femoral scaffold","volume":"18","author":"Liu","year":"2023","journal-title":"J Orthop Surg Res."},{"issue":"19","key":"bib20-20260916","doi-asserted-by":"crossref","first-page":"15933","DOI":"10.1021\/acsami.7b02552","article-title":"Mechanical Properties and in Vitro and in Vivo Biocompatibility of a-C\/a-C:Ti Nanomultilayer Films on Ti6Al4V Alloy as Medical Implants","volume":"9","author":"Li","year":"2017","journal-title":"ACS Appl Mater Interfaces."},{"issue":"10","key":"bib21-20260916","doi-asserted-by":"crossref","first-page":"2751","DOI":"10.3390\/jcm13102751","article-title":"The Measurement of the Oxidative Index of Polyethylene Obtained during Revision Hip Arthroplasty and Assessment of Its Variability Depending on the Degree of Osteolysis, Implantation Time, as Well as the Size and Material of the Utilized Head","volume":"13","author":"Sikora","year":"2024","journal-title":"J Clin Med."},{"issue":"1","key":"bib22-20260916","doi-asserted-by":"crossref","first-page":"9621","DOI":"10.1038\/s41598-025-89056-3","article-title":"Microstructure and properties of TC4 titanium alloy micro-arc oxide composite coating based on laser surface texturing","volume":"15","author":"Ma","year":"2025","journal-title":"Sci Rep."},{"issue":"2","key":"bib23-20260916","doi-asserted-by":"crossref","first-page":"315","DOI":"10.3390\/ma14020315","article-title":"Properties and Classification of Diamond-Like Carbon Films","volume":"14","author":"Ohtake","year":"2021","journal-title":"Materials (Basel)."},{"issue":"4","key":"bib24-20260916","doi-asserted-by":"crossref","first-page":"e0175084","DOI":"10.1371\/journal.pone.0175084","article-title":"Effect of frequency on fretting wear behavior of Ti\/TiN multilayer film on depleted uranium","volume":"12","author":"Wu","year":"2017","journal-title":"PLoS One."},{"key":"bib25-20260916","doi-asserted-by":"crossref","first-page":"43","DOI":"10.2174\/1874325000802010043","article-title":"Load-bearing biomedical applications of diamond-like carbon coatings - current status","volume":"2","author":"Alakoski","year":"2008","journal-title":"Open Orthop J."},{"issue":"4","key":"bib26-20260916","doi-asserted-by":"crossref","first-page":"900","DOI":"10.2106\/JBJS.H.00668","article-title":"Articular cartilage degeneration following the treatment of focal cartilage defects with ceramic metal implants and compared with microfracture","volume":"91","author":"Custers","year":"2009","journal-title":"J Bone Joint Surg Am."},{"issue":"1","key":"bib27-20260916","doi-asserted-by":"crossref","first-page":"6824","DOI":"10.1038\/s41598-024-57316-3","article-title":"Effect of laser beam incidence angle on weld formation mechanism and corrosion resistance of T2 copper\/304 stainless steel","volume":"14","author":"Wang","year":"2024","journal-title":"Sci Rep."},{"key":"bib28-20260916","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.knee.2021.11.001","article-title":"Focal articular surface replacement as primary treatment for focal chondral defects of the femoral condyles: A series of 157 cases","volume":"34","author":"van der Stok","year":"2022","journal-title":"Knee."},{"issue":"46","key":"bib29-20260916","doi-asserted-by":"crossref","first-page":"9479","DOI":"10.1039\/D2TB01616H","article-title":"A review on in vitro\/in vivo response of additively manufactured Ti-6Al-4V alloy","volume":"10","author":"Alipour","year":"2022","journal-title":"J Mater Chem B."},{"key":"bib30-20260916","doi-asserted-by":"crossref","first-page":"137866","DOI":"10.1016\/j.jcis.2025.137866","article-title":"Inherent variation in surface roughness of Selective Laser Melting (SLM) printed titanium caused by build angle changes the mechanomicrobiocidal effectiveness of nanostructures","volume":"696","author":"Huang","year":"2025","journal-title":"J Colloid Interface Sci."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.26.00538","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T18:00:37Z","timestamp":1789581637000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.26.00538"}},"subtitle":["In Vivo Performance in a Porcine Model"],"short-title":[],"issued":{"date-parts":[[2026,9,16]]},"references-count":30,"URL":"https:\/\/doi.org\/10.2106\/jbjs.26.00538","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,16]]}}}