{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T19:03:21Z","timestamp":1789499001133,"version":"build-2803163510"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Infection following extensor mechanism reconstruction (EMR) with Marlex mesh (C.R. Bard) is devastating and limb-threatening. The purpose of this study was to evaluate whether vancomycin-loaded mesh reduces staphylococcal infection in a murine EMR model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Mouse-sized, 8-layer mesh constructs were fabricated to simulate clinical reconstruction and soaked in a vancomycin solution (50 mg\/mL) for in vitro and in vivo testing. Three methicillin-resistant clinical isolates from human periprosthetic\n                      <jats:italic toggle=\"yes\">Staphylococcus aureus, Staphylococcus epidermidis, and Staphylococcus lugdunensis<\/jats:italic>\n                      knee infections were evaluated. In vitro testing assessed vancomycin loading capacity, mechanical properties, antibacterial activity, and inhibition of biofilm formation. For in vivo experiments, plain or vancomycin-loaded mesh was implanted into C57BL\/6 mouse extensor mechanisms, which were intraoperatively contaminated with 1 of the 3 study isolates (5 per group). Mesh and surrounding tissue were harvested for quantitative culture on postoperative day 9.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      For all 3 isolates, vancomycin-loaded mesh produced zones of inhibition and exhibited antibacterial activity through at least 3 days in vitro (p &lt; 0.0001). Mechanical testing revealed that loading mesh with vancomycin did not negatively impact tensile strength, hysteresis, or suture pull-through properties. In vitro testing of inhibition of biofilm formation demonstrated reduced colony-forming units 6 hours after inoculation, which remained low throughout the 9-day experimental period (p &lt; 0.05 for all isolates). In vivo, vancomycin-loaded mesh reduced bacterial burden on mesh and in surrounding tissue by &gt;3 log\n                      <jats:sub>10<\/jats:sub>\n                      compared with plain mesh for all 3 isolates (p &lt; 0.01 for both mesh and tissue).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Vancomycin-loaded mesh provided in vitro antibacterial activity without compromising mesh mechanical properties and reduced staphylococcal infection in a murine EMR model. Further work is needed to evaluate translational potential and safety before clinical application.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>Mesh-associated infection after EMR is devastating and difficult to treat. These preclinical findings suggest that local vancomycin delivery may serve as an adjunct to systemic prophylaxis, warranting further study before clinical use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.26.00619","type":"journal-article","created":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T18:08:26Z","timestamp":1789495706000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Vancomycin-Loaded Mesh Reduces Staphylococcal Infection in a Murine Extensor Mechanism Reconstruction Model"],"prefix":"10.2106","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9480-8224","authenticated-orcid":false,"given":"Tsung-Li","family":"Lin","sequence":"first","affiliation":[{"name":"Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"},{"name":"Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan"},{"name":"Department of Sports Medicine, College of Health Care, China Medical University, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3151-877X","authenticated-orcid":false,"given":"Nicholas A.","family":"Bedard","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6021-4033","authenticated-orcid":false,"given":"Melissa J.","family":"Karau","sequence":"additional","affiliation":[{"name":"Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-2570-4250","authenticated-orcid":false,"given":"Sebastian C.","family":"Herren","sequence":"additional","affiliation":[{"name":"Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6344-4141","authenticated-orcid":false,"given":"Robin","family":"Patel","sequence":"additional","affiliation":[{"name":"Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"},{"name":"Division of Public Health, Infectious Diseases, and Occupational Medicine, Department of Medicine, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2398-1724","authenticated-orcid":false,"given":"Matthew P.","family":"Abdel","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,15]]},"reference":[{"issue":"7","key":"bib1-20260915","doi-asserted-by":"crossref","first-page":"4411","DOI":"10.1007\/s00402-022-04718-5","article-title":"Extensor mechanism reconstruction with allograft following total knee arthroplasty: a systematic review and meta-analysis of Achilles tendon versus extensor mechanism allografts for isolated chronic patellar tendon ruptures","volume":"143","author":"Balato","year":"2023","journal-title":"Arch Orthop Trauma Surg."},{"issue":"4","key":"bib2-20260915","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1016\/j.arth.2024.10.004","article-title":"Very high early failure rate following primary repair of acute extensor mechanism disruption after total knee arthroplasty","volume":"40","author":"Neitzke","year":"2025","journal-title":"J Arthroplasty."},{"issue":"2","key":"bib3-20260915","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.2106\/JBJS.ST.18.00106","article-title":"Extensor mechanism reconstruction with use of Marlex mesh","volume":"9","author":"Abdel","year":"2019","journal-title":"JBJS Essent Surg Tech."},{"issue":"7","key":"bib4-20260915","doi-asserted-by":"crossref","first-page":"608","DOI":"10.2106\/JBJS.23.01006","article-title":"Marlex mesh reconstruction of the extensor mechanism: A concise 5-year follow-up of 2 previous reports","volume":"106","author":"Abdel","year":"2024","journal-title":"J Bone Joint Surg Am."},{"issue":"6S","key":"bib5-20260915","doi-asserted-by":"crossref","first-page":"S281","DOI":"10.1016\/j.arth.2021.10.022","article-title":"Early infection after aseptic revision knee arthroplasty: Prevalence and predisposing risk factors","volume":"37","author":"Cochrane","year":"2022","journal-title":"J Arthroplasty."},{"issue":"1","key":"bib6-20260915","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1007\/s00402-025-05991-w","article-title":"Extensor mechanism disruption following primary and revision total knee arthroplasty: a systematic review and meta-analysis","volume":"145","author":"Rajgopal","year":"2025","journal-title":"Arch Orthop Trauma Surg."},{"issue":"5","key":"bib7-20260915","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.arth.2019.01.027","article-title":"Longer operative time results in a higher rate of subsequent periprosthetic joint infection in patients undergoing primary joint arthroplasty","volume":"34","author":"Wang","year":"2019","journal-title":"J Arthroplasty."},{"issue":"5","key":"bib8-20260915","doi-asserted-by":"crossref","first-page":"e70068","DOI":"10.1111\/iwj.70068","article-title":"Risk factors for surgical site infections after orthopaedic surgery: A meta-analysis and systematic review","volume":"22","author":"Liu","year":"2025","journal-title":"Int Wound J."},{"issue":"3","key":"bib9-20260915","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1097\/CORR.0000000000002826","article-title":"Allograft or synthetic mesh extensor mechanism reconstruction after TKA carries a high risk of infection, revision, and extensor lag","volume":"482","author":"Baker","year":"2024","journal-title":"Clin Orthop Relat Res."},{"issue":"6","key":"bib10-20260915","doi-asserted-by":"crossref","first-page":"1879","DOI":"10.1016\/j.arth.2018.01.022","article-title":"High failure rates of concomitant periprosthetic joint infection and extensor mechanism disruption","volume":"33","author":"Anderson","year":"2018","journal-title":"J Arthroplasty."},{"issue":"3","key":"bib11-20260915","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1007\/s00464-012-2545-4","article-title":"An experimental study exploring the relationship between the size of bacterial inoculum and bacterial adherence to prosthetic mesh","volume":"27","author":"Sanders","year":"2013","journal-title":"Surg Endosc."},{"issue":"2","key":"bib12-20260915","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1111\/j.1574-695X.2012.00948.x","article-title":"Kinetics and morphology of polymicrobial biofilm formation on polypropylene mesh","volume":"65","author":"Stoodley","year":"2012","journal-title":"FEMS Immunol Med Microbiol."},{"issue":"8","key":"bib13-20260915","doi-asserted-by":"crossref","first-page":"S294","DOI":"10.1016\/j.arth.2024.04.081","article-title":"The infected polypropylene mesh: When does biofilm form and which antiseptic solution most effectively removes it?","volume":"39","author":"Jo","year":"2024","journal-title":"J Arthroplasty."},{"issue":"2S","key":"bib14-20260915","doi-asserted-by":"crossref","first-page":"S279","DOI":"10.1016\/j.arth.2018.09.012","article-title":"Hip and knee section, prevention, antimicrobials (systemic): Proceedings of International Consensus on Orthopedic Infections","volume":"34","author":"Aboltins","year":"2019","journal-title":"J Arthroplasty."},{"issue":"3","key":"bib15-20260915","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1007\/s11605-012-2099-8","article-title":"Does presoaking synthetic mesh in antibiotic solution reduce mesh infections? An experimental study","volume":"17","author":"Sadava","year":"2013","journal-title":"J Gastrointest Surg."},{"issue":"5","key":"bib16-20260915","doi-asserted-by":"crossref","first-page":"e0126711","DOI":"10.1371\/journal.pone.0126711","article-title":"Inhibition of Staphylococcus aureus adhesion to the surface of a reticular heavyweight polypropylene mesh soaked in a combination of chlorhexidine and allicin: an in vitro study","volume":"10","author":"P\u00e9rez-K\u00f6hler","year":"2015","journal-title":"PLoS One."},{"issue":"6","key":"bib17-20260915","doi-asserted-by":"crossref","first-page":"3699","DOI":"10.1021\/acsbiomaterials.3c00311","article-title":"Mechanical properties of smart polypropylene meshes: Effects of mesh architecture, plasma treatment, thermosensitive coating, and sterilization process","volume":"9","author":"Lanzalaco","year":"2023","journal-title":"ACS Biomater Sci Eng."},{"issue":"8","key":"bib18-20260915","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1302\/2046-3758.158.BJR-2025-0522.R2","article-title":"In vitro evaluation of vancomycin-loaded Marlex mesh against staphylococci isolated from periprosthetic joint infection","volume":"15","author":"Hellou","year":"2026","journal-title":"Bone Joint Res."},{"issue":"11","key":"bib19-20260915","doi-asserted-by":"crossref","first-page":"3311","DOI":"10.1016\/j.arth.2020.05.072","article-title":"Enhanced biomechanical performance of a modern polyester surgical mesh for extensor mechanism reconstruction in total knee arthroplasty","volume":"35","author":"Naveen","year":"2020","journal-title":"J Arthroplasty."},{"key":"bib20-20260915","doi-asserted-by":"crossref","first-page":"105987","DOI":"10.1016\/j.jmbbm.2023.105987","article-title":"A reliable and replicable test protocol for the mechanical evaluation of synthetic meshes","volume":"144","author":"Civilini","year":"2023","journal-title":"J Mech Behav Biomed Mater."},{"key":"bib21-20260915","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1097\/00003086-200001000-00019","article-title":"Human patellar tendon strain. A noninvasive, in vivo study","volume":"370","author":"Sheehan","year":"2000","journal-title":"Clin Orthop Relat Res."},{"issue":"7","key":"bib22-20260915","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1056\/NEJMoa061588","article-title":"Sonication of removed hip and knee prostheses for diagnosis of infection","volume":"357","author":"Trampuz","year":"2007","journal-title":"N Engl J Med."},{"issue":"Suppl 2","key":"bib23-20260915","first-page":"ofad500","article-title":"1295. Impact of inoculum size on clinical presentation in a murine knee arthroplasty model of periprosthetic joint infection","volume":"10","author":"Karau","year":"2023","journal-title":"Open Forum Infect Dis."},{"key":"bib24-20260915","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ijid.2016.08.007","article-title":"Staphylococcus lugdunensis, a serious pathogen in periprosthetic joint infections: comparison to Staphylococcus aureus and Staphylococcus epidermidis","volume":"51","author":"Lourtet-Hasco\u00ebt","year":"2016","journal-title":"Int J Infect Dis."},{"issue":"9","key":"bib25-20260915","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1002\/jor.22907","article-title":"Quantifying the natural history of biofilm formation in vivo during the establishment of chronic implant-associated Staphylococcus aureus osteomyelitis in mice to identify critical pathogen and host factors","volume":"33","author":"Nishitani","year":"2015","journal-title":"J Orthop Res."},{"issue":"6","key":"bib26-20260915","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.arthro.2011.02.003","article-title":"Bacterial adherence to high\u2014tensile strength sutures","volume":"27","author":"Masini","year":"2011","journal-title":"Arthroscopy."},{"issue":"3","key":"bib27-20260915","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1016\/j.arth.2015.10.015","article-title":"Serum and wound vancomycin levels after intrawound administration in primary total joint arthroplasty","volume":"32","author":"Johnson","year":"2017","journal-title":"J Arthroplasty."},{"issue":"6","key":"bib28-20260915","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1016\/j.arth.2024.01.003","article-title":"Efficacy of intrawound vancomycin in prevention of periprosthetic joint infection after primary total knee arthroplasty: A prospective double-blinded randomized control trial","volume":"39","author":"Mulpur","year":"2024","journal-title":"J Arthroplasty."},{"issue":"15","key":"bib29-20260915","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.2106\/JBJS.17.01165","article-title":"Extensor mechanism reconstruction with use of Marlex mesh: A series study of 77 total knee arthroplasties","volume":"100","author":"Abdel","year":"2018","journal-title":"J Bone Joint Surg Am."},{"issue":"7","key":"bib30-20260915","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1038\/s41579-018-0019-y","article-title":"Implant infections: adhesion, biofilm formation and immune evasion","volume":"16","author":"Arciola","year":"2018","journal-title":"Nat Rev Microbiol."},{"issue":"10","key":"bib31-20260915","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1302\/2046-3758.1110.BJR-2021-0495.R3","article-title":"Current therapeutic interventions combating biofilm-related infections in orthopaedics: a systematic review of in vivo animal studies","volume":"11","author":"Li","year":"2022","journal-title":"Bone Joint Res."},{"key":"bib32-20260915","doi-asserted-by":"crossref","first-page":"948151","DOI":"10.3389\/fcimb.2022.948151","article-title":"Development of an artificial synovial fluid useful for studying Staphylococcus epidermidis joint infections","volume":"12","author":"Stamm","year":"2022","journal-title":"Front Cell Infect Microbiol."},{"issue":"2","key":"bib33-20260915","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1128\/CMR.00111-13","article-title":"Prosthetic joint infection","volume":"27","author":"Tande","year":"2014","journal-title":"Clin Microbiol Rev."},{"issue":"9","key":"bib34-20260915","doi-asserted-by":"crossref","first-page":"3507","DOI":"10.1073\/pnas.1222878110","article-title":"Genomic responses in mouse models poorly mimic human inflammatory diseases","volume":"110","author":"Seok","year":"2013","journal-title":"Proc Natl Acad Sci U S A."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.26.00619","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T18:08:31Z","timestamp":1789495711000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.26.00619"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,15]]},"references-count":34,"URL":"https:\/\/doi.org\/10.2106\/jbjs.26.00619","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,15]]}}}