{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:40:58Z","timestamp":1787755258138,"version":"build-2784847793"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JBJS Case Connector"],"published-print":{"date-parts":[[2017,6]]},"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>Three patients who underwent uncomplicated total knee arthroplasty with use of the Prineo (Ethicon) wound-closure system had development of allergic contact dermatitis. All patients were started on Keflex (cephalexin), and two were started on topical corticosteroid. In all patients, the reaction resolved within weeks.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>To our knowledge, the present report describes the first case series of patients in whom allergic contact dermatitis developed in association with the use of the Prineo wound-closure system during orthopaedic procedures. The presentation can range from blistering to erythematous papules and vesicles to crusted plaques that resolve with Keflex and topical corticosteroid cream.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.17.00064","type":"journal-article","created":{"date-parts":[[2017,6,28]],"date-time":"2017-06-28T20:55:27Z","timestamp":1498683327000},"page":"e39-e39","source":"Crossref","is-referenced-by-count":19,"title":["Allergic Dermatitis After Total Knee Arthroplasty Using the Prineo Wound-Closure Device"],"prefix":"10.2106","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0028-1394","authenticated-orcid":false,"given":"Ferdinand J.","family":"Chan","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyle","family":"Richardson","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sun Jin","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2017,6,28]]},"reference":[{"issue":"5","key":"bib1-20230712","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1016\/j.athoracsur.2009.06.047","article-title":"Randomized prospective study comparing conventional subcuticular skin closure with Dermabond skin glue after saphenous vein harvesting","volume":"88","author":"Krishnamoorthy","year":"2009","journal-title":"Ann Thorac Surg."},{"issue":"3","key":"bib2-20230712","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s00266-004-3110-x","article-title":"The use of tissue adhesive for skin closure in body contouring surgery","volume":"28","author":"Nahas","year":"2004","journal-title":"Aesthetic Plast Surg."},{"issue":"2","key":"bib4-20230712","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1007\/s00266-011-9819-4","article-title":"Effective wound closure with a new two-component wound closure device (Prineo\u2122) in excisional body-contouring surgery: experience in over 200 procedures","volume":"36","author":"Huemer","year":"2012","journal-title":"Aesthetic Plast Surg."},{"issue":"3","key":"bib5-20230712","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1007\/s00266-013-0123-3","article-title":"Use of 2-octyl cyanoacrylate together with a self-adhering mesh (Dermabond\u2122 Prineo\u2122) for skin closure following abdominoplasty: an open, prospective, controlled, randomized, clinical study","volume":"37","author":"Parvizi","year":"2013","journal-title":"Aesthetic Plast Surg."},{"issue":"4","key":"bib6-20230712","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.asj.2009.02.019","article-title":"Severe allergic reaction to Dermabond","volume":"29","author":"Perry","year":"2009","journal-title":"Aesthet Surg J."},{"issue":"2","key":"bib7-20230712","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/DER.0000000000000018","article-title":"Allergic contact dermatitis to dermabond (2-octyl cyanoacrylate) after total knee arthroplasty","volume":"25","author":"Durando","year":"2014","journal-title":"Dermatitis."},{"key":"bib8-20230712","doi-asserted-by":"crossref","first-page":"642595","DOI":"10.1155\/2015\/642595","article-title":"Rash with Dermabond Prineo Skin Closure System use in bilateral reduction mammoplasty: a case series","volume":"2015","author":"Knackstedt","year":"2015","journal-title":"Case Rep Med."},{"issue":"6","key":"bib9-20230712","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1111\/j.1398-9995.2009.02243.x","article-title":"Extensive allergic reaction to a new wound closure device (Prineo)","volume":"65","author":"Dunst","year":"2010","journal-title":"Allergy."},{"issue":"286","key":"bib10-20230712","article-title":"Dermatologic complications of Dermabond after orthopaedic surgery: a case report and review of the literature","volume":"6","author":"Carayannopoulos","year":"2016","journal-title":"J Clin Exp Pathol."},{"issue":"5","key":"bib11-20230712","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1111\/j.1600-0536.2010.01720.x","article-title":"Allergic contact dermatitis to Dermabond after orthopaedic joint replacement","volume":"62","author":"El-Dars","year":"2010","journal-title":"Contact Dermatitis."},{"issue":"2","key":"bib12-20230712","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/DER.0000000000000163","article-title":"Severe allergic contact dermatitis to Dermabond Prineo, a topical skin adhesive of 2-octyl cyanoacrylate increasingly used in surgeries to close wounds","volume":"27","author":"Davis","year":"2016","journal-title":"Dermatitis."},{"issue":"6","key":"bib13-20230712","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1111\/j.1600-0536.1997.tb02460.x","article-title":"10 years of patch testing with the (meth)acrylate series","volume":"37","author":"Kanerva","year":"1997","journal-title":"Contact Dermatitis."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01709767-201707020-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:40:14Z","timestamp":1787751614000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01709767-201707020-00018"}},"subtitle":["A Report of Three Cases"],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":12,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.17.00064","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6]]}}}