{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:43:14Z","timestamp":1787755394018,"version":"build-2784847793"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JBJS Case Connector"],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>Eighteen months after implantation of a C6-C7 cervical artificial disc (ProDisc-C; DePuy Synthes), a 44-year-old woman presented with right-sided C7 radiculopathy. Imaging revealed posterior subsidence of the prosthesis, with C7 foraminal stenosis. An ultrasonic curet was used to safely and effectively extract the prosthesis without neurologic complication; safe access for the insertion of an intervertebral cage was facilitated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The ultrasonic curet was a safe and effective adjunct for revision artificial cervical disc replacement surgery; this technique may help to reduce potential injury to neural structures in a procedure with a traditionally high complication rate.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.17.00091","type":"journal-article","created":{"date-parts":[[2018,1,24]],"date-time":"2018-01-24T11:51:06Z","timestamp":1516794666000},"page":"e5-e5","source":"Crossref","is-referenced-by-count":4,"title":["Use of an Ultrasonic Bone Curet for the Extraction of a Cervical Artificial Disc: A Novel Application"],"prefix":"10.2106","volume":"8","author":[{"given":"J.","family":"Timothy","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Leeds General Infirmary, Leeds, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Petralia","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Santa Chiara Hospital, Trento, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3488-7506","authenticated-orcid":false,"given":"J.R.","family":"Wilson","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Leeds General Infirmary, Leeds, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2018,1,24]]},"reference":[{"issue":"Suppl 1","key":"bib1-20230713","doi-asserted-by":"crossref","first-page":"S87","DOI":"10.1007\/s00590-014-1469-1","article-title":"Comparison of the short- and long-term treatment effect of cervical disk replacement and anterior cervical disk fusion: a meta-analysis","volume":"25","author":"Muheremu","year":"2015","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"S1","key":"bib2-20230713","first-page":"9","article-title":"Total disc replacement in the cervical spine: a systematic review evaluating long-term safety","volume":"3","author":"Anderson","year":"2012","journal-title":"Evid Based Spine Care J."},{"issue":"Suppl 4","key":"bib3-20230713","doi-asserted-by":"crossref","first-page":"S536","DOI":"10.1007\/s00586-014-3677-0","article-title":"Core herniation after implantation of a cervical artificial disc: case report","volume":"24","author":"Brenke","year":"2015","journal-title":"Eur Spine J."},{"issue":"24","key":"bib4-20230713","doi-asserted-by":"crossref","first-page":"e7163","DOI":"10.1097\/MD.0000000000007163","article-title":"The prevalence of heterotopic ossification among patients after cervical artificial disc replacement: a systematic review and meta-analysis","volume":"96","author":"Kong","year":"2017","journal-title":"Medicine (Baltimore)."},{"issue":"VideoSuppl1","key":"bib5-20230713","doi-asserted-by":"crossref","first-page":"V3","DOI":"10.3171\/2017.1.FocusVid.16382","article-title":"Surgical technique for revision surgery of cervical artificial disc replacements","volume":"42","author":"Onken","year":"2017","journal-title":"Neurosurg Focus."},{"key":"bib6-20230713","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.clineuro.2016.10.021","article-title":"Revision surgery for cervical artificial disc: surgical technique and clinical results","volume":"152","author":"Onken","year":"2017","journal-title":"Clin Neurol Neurosurg."},{"issue":"6","key":"bib7-20230713","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.aott.2016.04.004","article-title":"Revision surgeries following artificial disc replacement of cervical spine","volume":"50","author":"Park","year":"2016","journal-title":"Acta Orthop Traumatol Turc."},{"issue":"12","key":"bib8-20230713","doi-asserted-by":"crossref","first-page":"2841","DOI":"10.1016\/j.spinee.2014.03.037","article-title":"Comparison of revision surgeries for one- to two-level cervical TDR and ACDF from 2002 to 2011","volume":"14","author":"Nandyala","year":"2014","journal-title":"Spine J."},{"issue":"3","key":"bib9-20230713","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1097\/00006534-199903000-00035","article-title":"The effects of ultrasonic energy on peripheral nerves: implications for ultrasound-assisted liposuction","volume":"103","author":"Howard","year":"1999","journal-title":"Plast Reconstr Surg."},{"key":"bib10-20230713","doi-asserted-by":"crossref","first-page":"8428530","DOI":"10.1155\/2016\/8428530","article-title":"Technical aspects on the use of ultrasonic bone shaver in spine surgery: experience in 307 patients","volume":"2016","author":"Hazer","year":"2016","journal-title":"Biomed Res Int."},{"issue":"8","key":"bib11-20230713","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1097\/BPO.0000000000000211","article-title":"Spinal decompression in achondroplastic patients using high-speed drill versus ultrasonic bone curette: technical note and outcomes in 30 cases","volume":"34","author":"Bydon","year":"2014","journal-title":"J Pediatr Orthop."},{"issue":"4","key":"bib12-20230713","doi-asserted-by":"crossref","first-page":"431","DOI":"10.3171\/spi.2005.2.4.0431","article-title":"Technical advantages of an ultrasonic bone curette in spinal surgery","volume":"2","author":"Nakagawa","year":"2005","journal-title":"J Neurosurg Spine."},{"issue":"2","key":"bib13-20230713","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s00701-005-0655-7","article-title":"The use of ultrasonic bone curettes in spinal surgery","volume":"148","author":"Nakase","year":"2006","journal-title":"Acta Neurochir (Wien)."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01709767-201803000-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:42:10Z","timestamp":1787751730000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01709767-201803000-00007"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2018,1,24]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.17.00091","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,24]]}}}