{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:42:32Z","timestamp":1787755352753,"version":"build-2784847793"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JBJS Case Connector"],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>An immunosuppressed 51-year-old man sustained a ballistic injury about the site of a primary total hip arthroplasty, which had been performed for osteonecrosis of the femoral head 2 years earlier. He was treated with arthroscopic debridement and irrigation, inspection of the implants, and removal of foreign bodies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Ballistic injury to a hip arthroplasty site with retained foreign bodies is an unusual injury. Hip arthroscopy may represent a minimally invasive treatment option for implant inspection, joint debridement, and removal of intra-articular fragments while minimizing the risk of soft-tissue complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.18.00204","type":"journal-article","created":{"date-parts":[[2019,3,28]],"date-time":"2019-03-28T14:57:47Z","timestamp":1553785067000},"page":"e18-e18","source":"Crossref","is-referenced-by-count":5,"title":["Arthroscopic Treatment of a Low-Velocity Gunshot Injury to a Primary Total Hip Arthroplasty"],"prefix":"10.2106","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6357-7531","authenticated-orcid":false,"given":"Matthew N.","family":"Fournier","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0760-5355","authenticated-orcid":false,"given":"Carson M.","family":"Rider","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3426-5245","authenticated-orcid":false,"given":"Catherine R.","family":"Olinger","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory D.","family":"Dabov","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6229-1515","authenticated-orcid":false,"given":"William M.","family":"Mihalko","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc J.","family":"Mihalko","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,3]]},"reference":[{"issue":"1","key":"bib1-20230712","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0030-5898(20)31962-3","article-title":"Gunshot wound injuries. Frequency and cost analyses in south central Los Angeles","volume":"26","author":"Weaver","year":"1995","journal-title":"Orthop Clin North Am."},{"issue":"1","key":"bib2-20230712","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s40621-017-0120-0","article-title":"Cost of hospitalization for firearm injuries by firearm type, intent, and payer in the United States","volume":"4","author":"Peek-Asa","year":"2017","journal-title":"Inj Epidemiol."},{"issue":"10","key":"bib3-20230712","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/BOT.0b013e3181cf03ea","article-title":"Civilian gunshot wounds of the hip and pelvis","volume":"24","author":"Bartkiw","year":"2010","journal-title":"J Orthop Trauma."},{"issue":"6","key":"bib4-20230712","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1097\/BOT.0000000000000823","article-title":"Infection and complications after low-velocity intra-articular gunshot injuries","volume":"31","author":"Nguyen","year":"2017","journal-title":"J Orthop Trauma."},{"issue":"2","key":"bib5-20230712","doi-asserted-by":"crossref","first-page":"254","DOI":"10.2106\/00004623-197860020-00021","article-title":"Lead intoxication and traumatic arthritis of the hip secondary to retained bullet fragments. A case report","volume":"60","author":"Windler","year":"1978","journal-title":"J Bone Joint Surg Am."},{"key":"bib6-20230712","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1186\/1752-1947-1-171","article-title":"Bullet-induced synovitis as a cause of secondary osteoarthritis of the hip joint: A case report and review of literature","volume":"1","author":"Rehman","year":"2007","journal-title":"J Med Case Rep."},{"issue":"3","key":"bib7-20230712","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1053\/j.jfas.2016.12.005","article-title":"Ankle lead arthropathy and systemic lead toxicity secondary to a gunshot wound after 49 years: a case report","volume":"56","author":"Ramji","year":"2017","journal-title":"J Foot Ankle Surg."},{"issue":"4","key":"bib8-20230712","doi-asserted-by":"crossref","first-page":"411","DOI":"10.3928\/0147-7447-20050401-20","article-title":"Systemic lead poisoning due to an intra-articular bullet","volume":"28","author":"Sokolowski","year":"2005","journal-title":"Orthopedics."},{"issue":"2","key":"bib9-20230712","doi-asserted-by":"crossref","first-page":"e217","DOI":"10.1016\/j.eats.2015.11.001","article-title":"Arthroscopic bullet removal from the central and peripheral compartments of the hip joint","volume":"5","author":"Howse","year":"2016","journal-title":"Arthrosc Tech."},{"issue":"9","key":"bib10-20230712","doi-asserted-by":"crossref","first-page":"E121","DOI":"10.1016\/j.arthro.2003.09.014","article-title":"Arthroscopic removal of a bullet embedded in the acetabulum","volume":"19","author":"Mineo","year":"2003","journal-title":"Arthroscopy."},{"issue":"3","key":"bib11-20230712","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.arthro.2004.10.005","article-title":"Arthroscopic bullet removal from the acetabulum","volume":"21","author":"Singleton","year":"2005","journal-title":"Arthroscopy."},{"issue":"5","key":"bib12-20230712","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1002\/bjs.1800540509","article-title":"The mechanisms of primary infection of bullet wounds","volume":"54","author":"Thoresby","year":"1967","journal-title":"Br J Surg."},{"issue":"1","key":"bib13-20230712","first-page":"E14","article-title":"Low velocity gunshot wounds result in significant contamination regardless of ballistic characteristics","volume":"43","author":"Weinstein","year":"2014","journal-title":"Am J Orthop (Belle Mead NJ)."},{"issue":"9","key":"bib14-20230712","doi-asserted-by":"crossref","first-page":"8046","DOI":"10.1016\/j.actbio.2013.05.005","article-title":"Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms","volume":"9","author":"Gallo","year":"2013","journal-title":"Acta Biomater."},{"issue":"1","key":"bib15-20230712","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5435\/00124635-200701000-00006","article-title":"Wear and osteolysis around total knee arthroplasty","volume":"15","author":"Naudie","year":"2007","journal-title":"J Am Acad Orthop Surg."},{"issue":"2","key":"bib16-20230712","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1177\/112070001002000221","article-title":"Arthroscopic bullet extraction from the hip in the lateral decubitus position","volume":"20","author":"Sozen","year":"2010","journal-title":"Hip Int."},{"issue":"2-3","key":"bib17-20230712","first-page":"98","article-title":"[Removal of the bullet from the hip joint by medial arthrotomy]","volume":"19","author":"Typovsky","year":"1952","journal-title":"Acta Chir Orthop Traumatol Cech."},{"issue":"3","key":"bib18-20230712","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/S0749-8063(87)80065-8","article-title":"Arthroscopic removal of entrapped debris following dislocation of a total hip arthroplasty","volume":"3","author":"Nordt","year":"1987","journal-title":"Arthroscopy."},{"issue":"6","key":"bib19-20230712","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1016\/j.arthro.2009.11.013","article-title":"Arthroscopic treatment of unstable total hip replacement","volume":"26","author":"Cu\u00e9llar","year":"2010","journal-title":"Arthroscopy."},{"issue":"1","key":"bib20-20230712","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/s11999-008-0525-8","article-title":"The role of arthroscopy in evaluation of painful hip arthroplasty","volume":"467","author":"McCarthy","year":"2009","journal-title":"Clin Orthop Relat Res."},{"issue":"7","key":"bib21-20230712","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.3899\/jrheum.101009","article-title":"Incidence and risk factors for serious infection in patients with rheumatoid arthritis treated with tumor necrosis factor inhibitors: a report from the Registry of Japanese Rheumatoid Arthritis Patients for Longterm Safety","volume":"38","author":"Komano","year":"2011","journal-title":"J Rheumatol."},{"issue":"2","key":"bib22-20230712","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1002\/art.21841","article-title":"Tumor necrosis factor inhibitor therapy and risk of serious postoperative orthopedic infection in rheumatoid arthritis","volume":"55","author":"Giles","year":"2006","journal-title":"Arthritis Rheum."},{"issue":"4","key":"bib23-20230712","first-page":"253","article-title":"Periprosthetic Joint Infection in Patients Receiving TNF\u03b1 Antagonists","volume":"72","author":"Snir","year":"2014","journal-title":"Bull Hosp Jt Dis (2013)."},{"issue":"6","key":"bib24-20230712","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1046\/j.1524-475x.2000.00547.x","article-title":"Inhibition of tumor necrosis factor-alpha attenuates wound breaking strength in rats","volume":"8","author":"Lee","year":"2000","journal-title":"Wound Repair Regen."},{"issue":"12","key":"bib25-20230712","doi-asserted-by":"crossref","first-page":"1423","DOI":"10.1097\/DCR.0b013e3182a48505","article-title":"The effect of anti-tumor necrosis factor alpha agents on postoperative anastomotic complications in Crohn\u2019s disease: a systematic review","volume":"56","author":"El-Hussuna","year":"2013","journal-title":"Dis Colon Rectum."},{"issue":"2","key":"bib26-20230712","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1007\/s11999-010-1555-6","article-title":"Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners","volume":"469","author":"Shen","year":"2011","journal-title":"Clin Orthop Relat Res."},{"issue":"8","key":"bib27-20230712","doi-asserted-by":"crossref","first-page":"e727","DOI":"10.3928\/01477447-20150804-62","article-title":"Thin-walled cross-linked acetabular liners need not exhibit reduced locking strength","volume":"38","author":"Murtha","year":"2015","journal-title":"Orthopedics."},{"issue":"19","key":"bib28-20230712","doi-asserted-by":"crossref","first-page":"e6687","DOI":"10.1097\/MD.0000000000006687","article-title":"Adverse local tissue reaction after 2 revision hip replacements for ceramic liner fracture: A case report","volume":"96","author":"Antoniac","year":"2017","journal-title":"Medicine (Baltimore)."},{"issue":"Suppl 4","key":"bib29-20230712","doi-asserted-by":"crossref","first-page":"S116","DOI":"10.1016\/j.injury.2016.07.059","article-title":"Revision of ceramic fracture with ceramic-on-polyethylene in total hip arthroplasty: Medium-term results","volume":"47","author":"Zagra","year":"2016","journal-title":"Injury."},{"issue":"1","key":"bib30-20230712","first-page":"197","article-title":"Abrasive wear and metallosis associated with cross-linked polyethylene in total hip arthroplasty","volume":"28","author":"O\u2019Brien","year":"2013","journal-title":"J Arthroplasty."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01709767-201903000-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:41:42Z","timestamp":1787751702000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01709767-201903000-00018"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.18.00204","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}