{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:35:50Z","timestamp":1787754950793,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JBJS Case Connector"],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 61-year-old woman with left shoulder osteoarthritis underwent a left shoulder hemiarthroplasty. The wound was closed using the Dermabond Prineo system. The patient had a severe and progressive reaction during the first 2 weeks that necessitated debridement and skin grafting. Three months after surgery, the patient was doing well.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Severe reactions to 2-octyl cyanoacrylate are uncommon. The severity of the presented reaction is rare. However, surgeons using this closure method should be aware of potential reactions that may initially mimic infection. It is important to initiate appropriate treatment including removing the dressing, topical steroids, and\/or oral antihistamines, antibiotics, and possible surgical wound debridement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.18.00306","type":"journal-article","created":{"date-parts":[[2020,1,19]],"date-time":"2020-01-19T07:51:44Z","timestamp":1579420304000},"page":"e0306-e0306","source":"Crossref","is-referenced-by-count":15,"title":["Severe Wound Complication due to Prineo Surgical Dressing in Shoulder Hemiarthroplasty"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6272-9134","authenticated-orcid":false,"given":"Ryan C.","family":"Pate","sequence":"first","affiliation":[{"name":"Baylor Scott & White Orthopedics, Round Rock, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9292-9156","authenticated-orcid":false,"given":"Michael W.","family":"Neumeister","sequence":"additional","affiliation":[{"name":"Division of Orthopaedics and, Division of Plastic Surgery, Department of Surgery, Southern Illinois University, Springfield, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"key":"bib1-20230720","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/PRS.0000000000004726","article-title":"In search of an ideal closure method: a randomized, controlled trial of octyl-2-cyanoacrylate and adhesive mesh versus subcuticular suture in reduction mammoplasty","volume":"142","author":"Lee","year":"2018","journal-title":"Plast Reconstr Surg."},{"issue":"1","key":"bib2-20230720","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1185\/030079908X253807","article-title":"Use of 2-ocyl cyanoacrylate for skin closure of sternal incisions in cardiac surgery: observations of microbial barrier effects","volume":"24","author":"Souza","year":"2008","journal-title":"Curr Med Res Opin."},{"issue":"2","key":"bib3-20230720","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/DER.0000000000000163","article-title":"Severe allergic contact dermatitis to Dermabond Prineo, a topical skin adhesive of 2-octyl cyanoacrylate increasingly used in surgeries to close wounds","volume":"27","author":"Davis","year":"2016","journal-title":"Dermatitis."},{"issue":"12","key":"bib4-20230720","doi-asserted-by":"crossref","first-page":"3742","DOI":"10.1016\/j.arth.2017.07.012","article-title":"Characterizing the diagnosis and treatment of allergic contact dermatitis to 2-octyl cyanoacrylate used for skin closure in elective orthopedic surgery","volume":"32","author":"Chalmers","year":"2017","journal-title":"J Arthroplasty."},{"key":"bib5-20230720","doi-asserted-by":"crossref","first-page":"642595","DOI":"10.1155\/2015\/642595","article-title":"Rash with DERMABOND PRINEO skin closure system use in bilateral reduction mammoplasty: a case series","volume":"2015","author":"Knackstedt","year":"2015","journal-title":"Case Rep Med."},{"issue":"5","key":"bib6-20230720","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1111\/j.1600-0536.2010.01720.x","article-title":"Allergic contact dermatitis to Dermabond after orthopaedic joint replacement","volume":"62","author":"El-Dars","year":"2010","journal-title":"Contact Dermatitis."},{"issue":"2","key":"bib7-20230720","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.2106\/JBJS.CC.17.00064","article-title":"Allergic dermatitis after total knee arthroplasty using the Prineo wound closure device: a report of three cases","volume":"7","author":"Chan","year":"2017","journal-title":"JBJS Case Connect."},{"issue":"2","key":"bib8-20230720","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1007\/s00266-011-9819-4","article-title":"Effective wound closure with a new two-component wound closure device (Prineo) in excisional body-contouring surgery: experience in over 200 procedures","volume":"36","author":"Huemer","year":"2012","journal-title":"Aesthet Plast Surg."},{"issue":"5","key":"bib9-20230720","doi-asserted-by":"crossref","first-page":"e784","DOI":"10.3928\/01477447-20170531-03","article-title":"Use of 2-octyl cyanoacrylate adhesive and polymer mesh for wound closure in primary knee arthroplasty","volume":"40","author":"Holte","year":"2017","journal-title":"Orthopedics."},{"issue":"2","key":"bib10-20230720","doi-asserted-by":"crossref","first-page":"e289","DOI":"10.3928\/01477447-20170918-08","article-title":"Contact dermatitis reaction to 2-octyl cyanoacrylate following 3 orthopedic procedures","volume":"41","author":"Lake","year":"2018","journal-title":"Orthopedics."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.18.00306","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:35:15Z","timestamp":1787751315000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.18.00306"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.18.00306","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}