{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:38:20Z","timestamp":1787755100640,"version":"build-2784847793"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JBJS Case Connector"],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A traumatic displaced transverse periprosthetic acetabular fracture around a well-functioning Birmingham hip resurfacing prosthesis was treated with open reduction and internal fixation. The acetabular component was found to be well-fixed intraoperatively and did not require revision. The patient recovered with excellent clinical and radiographic results at the 1-year follow-up with a Harris Hip Score of 94.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Internal fixation, rather than revision arthroplasty, offers acceptable outcomes in patients with periprosthetic acetabular fractures about well-fixed hip resurfacing prostheses. Radiographic and intraoperative assessment of stability is critical in guiding treatment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.19.00230","type":"journal-article","created":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T04:41:45Z","timestamp":1575952905000},"page":"e0230-e0230","source":"Crossref","is-referenced-by-count":3,"title":["Acetabular Fracture Around a Birmingham Hip Resurfacing Prosthesis"],"prefix":"10.2106","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0334-2757","authenticated-orcid":false,"given":"Noah M.","family":"Joseph","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Case Western Reserve University, School of Medicine, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5044-8151","authenticated-orcid":false,"given":"Alexander","family":"Benedick","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Case Western Reserve University, School of Medicine, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1298-4751","authenticated-orcid":false,"given":"George","family":"Ochenjele","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Case Western Reserve University, School of Medicine, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019]]},"reference":[{"key":"bib1-20230811","doi-asserted-by":"crossref","first-page":"S89","DOI":"10.1097\/00003086-199608001-00009","article-title":"Metal on metal surface replacement of the hip: experience of the McMinn prosthesis","volume":"329","author":"McMinn","year":"1996","journal-title":"Clin Orthop Relat Res."},{"key":"bib2-20230811","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1302\/0301-620X.101B1.BJJ-2018-0702.R1","article-title":"The outcome and survival of metal-on-metal hip resurfacing in patients aged less than 50 years","volume":"101-B","author":"Scholes","year":"2019","journal-title":"Bone Joint J."},{"key":"bib3-20230811","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1302\/0301-620X.92B10.23504","article-title":"Birmingham hip resurfacing: the prevalence of failure","volume":"92","author":"Carrothers","year":"2010","journal-title":"J Bone Joint Surg Br."},{"key":"bib4-20230811","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1016\/j.injury.2005.02.011","article-title":"Fixation of a complex comminuted proximal femoral fracture in the presence of a Birmingham hip resurfacing prosthesis","volume":"36","author":"Aning","year":"2005","journal-title":"Injury."},{"issue":"1","key":"bib5-20230811","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.2106\/JBJS.CC.15.00262","article-title":"Trochanteric femoral fracture around a Birmingham Hip Resurfacing prosthesis","volume":"7","author":"Chou","year":"2017","journal-title":"JBJS Case Connect."},{"issue":"2","key":"bib6-20230811","doi-asserted-by":"crossref","first-page":"334.e1-4","DOI":"10.1016\/j.arth.2008.10.015","article-title":"Internal fixation after subtrochanteric femoral fracture after hip resurfacing arthroplasty","volume":"25","author":"Whittingham-Jones","year":"2010","journal-title":"J Arthroplasty."},{"issue":"10","key":"bib7-20230811","doi-asserted-by":"crossref","first-page":"1995","DOI":"10.1007\/s00264-015-2968-3","article-title":"Treatment algorithm of acetabular periprosthetic fractures","volume":"3","author":"Simon","year":"2015","journal-title":"Int Orthop."},{"issue":"8","key":"bib8-20230811","doi-asserted-by":"crossref","first-page":"e715","DOI":"10.3928\/01477447-20150804-60","article-title":"Short-term results of Birmingham Hip Resurfacing in the United States","volume":"38","author":"Nam","year":"2015","journal-title":"Orthopedics."},{"issue":"5","key":"bib9-20230811","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1007\/s00264-009-0821-2","article-title":"The Birmingham Hip Resurfacing: 5-year clinical and radiographic results from a district general hospital","volume":"34","author":"Ollivere","year":"2010","journal-title":"Int Orthop."},{"key":"bib10-20230811","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1302\/0301-620X.90B4.19648","article-title":"The five-year results of the Birmingham Hip Resurfacing arthroplasty","volume":"90","author":"Steffen","year":"2008","journal-title":"J Bone Joint Surg Br."},{"key":"bib11-20230811","first-page":"281","article-title":"Periprosthetic fractures of the acetabulum associated with a total hip arthroplasty","volume":"52","author":"Della Valle","year":"2003","journal-title":"Instr Course Lect."},{"issue":"9","key":"bib12-20230811","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.2106\/JBJS.H.00331","article-title":"Intraoperative periprosthetic fractures during total hip arthroplasty. Evaluation and management","volume":"90","author":"Davidson","year":"2008","journal-title":"J Bone Joint Surg Am."},{"issue":"8","key":"bib13-20230811","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.2106\/00004623-199608000-00011","article-title":"Periprosthetic fracture of the acetabulum after total hip arthroplasty","volume":"78","author":"Peterson","year":"1996","journal-title":"J Bone Joint Surg Am."},{"issue":"12","key":"bib14-20230811","first-page":"2626","article-title":"Early postoperative transverse pelvic fracture: a new complication related to revision arthroplasty with an uncemented cup","volume":"87","author":"Springer","year":"2005","journal-title":"J Bone Joint Surg Am."},{"issue":"8","key":"bib15-20230811","doi-asserted-by":"crossref","first-page":"1570.e17-9","DOI":"10.1016\/j.arth.2010.12.021","article-title":"Early postoperative acetabular discontinuity after total hip arthroplasty","volume":"26","author":"Desai","year":"2011","journal-title":"J Arthroplasty."},{"issue":"2","key":"bib16-20230811","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.arth.2014.09.013","article-title":"Periprosthetic fractures of the acetabulum during cup insertion, posterior column stability is crucial","volume":"30","author":"Laflamme","year":"2015","journal-title":"J Arthroplasty."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00230","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:37:28Z","timestamp":1787751448000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00230"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2019]]},"references-count":16,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.19.00230","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019]]}}}