{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:46:25Z","timestamp":1787755585857,"version":"build-2784847793"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JBJS Case Connector"],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 20-year-old man with a history of right lower extremity fibular hemimelia previously treated with PRECICE femoral nail lengthening presented with a broken magnetic nail and a displaced fracture through an ununited distraction osteogenesis site. Using a combination of techniques, we removed the broken implant while maintaining the achieved limb length and preserving the native biology without bone grafting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The unique challenges associated with the removal of a broken PRECICE femoral nail are described, with a technique for implant removal that preserves the achieved length, the innate biology of the distraction osteogenesis site, and promoting union without bone grafting.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.19.00267","type":"journal-article","created":{"date-parts":[[2020,2,17]],"date-time":"2020-02-17T05:33:37Z","timestamp":1581917617000},"page":"e0267-e0267","source":"Crossref","is-referenced-by-count":16,"title":["Management of a Broken PRECICE Femoral Nail at an Ununited Distraction Osteogenesis Site"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7766-8840","authenticated-orcid":false,"given":"Krystin A.","family":"Hidden","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0530-8322","authenticated-orcid":false,"given":"Mark T.","family":"Dahl","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6208-5490","authenticated-orcid":false,"given":"Thuan V.","family":"Ly","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"key":"bib1-20230720","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00003086-199404000-00003","article-title":"Complications of limb lengthening: a learning curve","volume":"301","author":"Dahl","year":"1994","journal-title":"Clin Orthop Relat Res."},{"key":"bib2-20230720","doi-asserted-by":"crossref","first-page":"3869","DOI":"10.1007\/s11999-014-3575-0","article-title":"Precision of the PRECISE internal bone lengthening nail","volume":"472","author":"Kirane","year":"2014","journal-title":"Clin Orthop Relat Res."},{"issue":"7","key":"bib3-20230720","doi-asserted-by":"crossref","first-page":"403","DOI":"10.5435\/JAAOS-22-07-403","article-title":"Motorized intramedullary nail for management of limb-length discrepancy deformity","volume":"22","author":"Rozbruch","year":"2014","journal-title":"J Am Acad Orthop Surg."},{"issue":"3","key":"bib4-20230720","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1586\/17434440.2015.1005604","article-title":"PRECICE intramedullary limb lengthening system","volume":"12","author":"Paley","year":"2015","journal-title":"Expert Rev Med Devices."},{"issue":"1","key":"bib5-20230720","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1080\/17453674.2018.1534321","article-title":"Limb lengthening and deformity correction with externally controlled motorized intramedullary nails: evaluation of 50 consecutive lengthenings","volume":"90","author":"Horn","year":"2019","journal-title":"Acta Orthop."},{"issue":"2","key":"bib6-20230720","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s00402-014-2121-6","article-title":"Breakage of cephalomedullary nailing in operative treatment of trochanteric and subtrochanteric femoral fractures","volume":"135","author":"von R\u00fcden","year":"2015","journal-title":"Arch Orthop Trauma Surg."},{"issue":"1","key":"bib7-20230720","doi-asserted-by":"crossref","first-page":"42","DOI":"10.3944\/AOTT.2012.2671","article-title":"Functional results of lower extremity lengthening by motorized intramedullary nails","volume":"46","author":"Dincyurek","year":"2012","journal-title":"Acta Orthop Traumatol Turc."},{"issue":"4","key":"bib8-20230720","doi-asserted-by":"crossref","first-page":"e36273","DOI":"10.5812\/atr.36273","article-title":"Limb lengthening using the PRECICE nail system: complications and results","volume":"5","author":"Wiebking","year":"2016","journal-title":"Arch Trauma Res."},{"issue":"1","key":"bib9-20230720","first-page":"1","article-title":"Premature consolidation with resultant implant failure using PRECICE femoral nail lengthening: a case report","volume":"6","author":"Morrison","year":"2016","journal-title":"J Bone Joint Surg Case Connect."},{"key":"bib10-20230720","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.1016\/j.injury.2015.07.033","article-title":"Case report: unusual complication with an intramedullary lengthening device 15 months after implantation","volume":"46","author":"Tiefenbock","year":"2015","journal-title":"Injury."},{"key":"bib11-20230720","doi-asserted-by":"crossref","first-page":"8032510","DOI":"10.1155\/2017\/8032510","article-title":"A comparison of the device-related complications of intramedullary lengthening nails using a new classification system","volume":"2017","author":"Lee","year":"2017","journal-title":"Biomed Res Int."},{"issue":"4","key":"bib12-20230720","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/0020-1383(95)90020-X","article-title":"Ex traction of broken intramedullary nails\u2014an improvement in technique","volume":"26","author":"Brewster","year":"1995","journal-title":"Injury."},{"issue":"10","key":"bib13-20230720","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.2106\/00004623-198870100-00004","article-title":"Broken intramedullary nails","volume":"70","author":"Franklin","year":"1988","journal-title":"J Bone Joint Surg Am."},{"key":"bib14-20230720","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.injury.2006.03.014","article-title":"Case report: a simple removal method of a broken proximal femoral nail (PFN)","volume":"37","author":"Gomez","year":"2006","journal-title":"Injury Extra."},{"issue":"1","key":"bib15-20230720","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1590\/1413-785220182601148079","article-title":"Method for removing broken proximal femoral nails using existing screw hole","volume":"26","author":"Man","year":"2018","journal-title":"Acta Orthop Bras."},{"key":"bib16-20230720","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/0020-1383(95)00103-G","article-title":"Multiple guide wire technique for removal of the short distal fragment of a fractured intramedullary nail","volume":"26","author":"Middleton","year":"1995","journal-title":"Injury."},{"key":"bib17-20230720","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1097\/00005131-200608000-00007","article-title":"Removal of a broken intramedullary nail with a narrow hollow","volume":"20","author":"Park","year":"2006","journal-title":"J Orthop Trauma."},{"issue":"2","key":"bib18-20230720","doi-asserted-by":"crossref","first-page":"113","DOI":"10.5435\/00124635-200802000-00009","article-title":"Removal of broken hardware","volume":"16","author":"Hak","year":"2008","journal-title":"J Am Acad Orthop Surg."},{"issue":"11","key":"bib19-20230720","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1097\/BOT.0b013e31824aed95","article-title":"The safe zone for external fixator pins in the femur","volume":"26","author":"Beltran","year":"2012","journal-title":"J Orthop Trauma."},{"issue":"6","key":"bib20-20230720","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/00005131-199808000-00002","article-title":"Neurologic and vascular structures at risk during anterior-posterior locking of retrograde femoral nails","volume":"12","author":"Riina","year":"1998","journal-title":"J Orthop Trauma."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00267","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:45:09Z","timestamp":1787751909000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00267"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.19.00267","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}