{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:45:52Z","timestamp":1787755552233,"version":"build-2784847793"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 47-year-old obese woman presented with a vertical shear (VS) pelvic ring injury after a motor vehicle accident around her previous posterior pelvic hardware. The patient underwent closed reduction with percutaneous posterior screw fixation using combined fluoroscopy and O-arm (Medtronic).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>A rare case of VS pelvic injury with indwelling posterior pelvic hardware does not automatically preclude placement of percutaneous sacroiliac and transiliac-transsacral screws. Combining fluoroscopic imaging and O-arm enables safe screw placement, saving patients from invasive surgeries.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.19.00601","type":"journal-article","created":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T16:52:02Z","timestamp":1591030322000},"page":"e0601-e0601","source":"Crossref","is-referenced-by-count":0,"title":["Vertical Shear Pelvic Ring Injury Adjacent to Retained Pelvic Hardware"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2227-2715","authenticated-orcid":false,"given":"Michael A.","family":"Yee","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Tennessee at Chattanooga, Chattanooga, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7173-6192","authenticated-orcid":false,"given":"Daniel T.","family":"Miles","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Tennessee at Chattanooga, Chattanooga, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J.","family":"Nowotarski","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Tennessee at Chattanooga, Chattanooga, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"key":"bib1-20230720","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1097\/00005373-198604000-00004","article-title":"Early open reduction and internal fixation of the disrupted pelvic ring","volume":"26","author":"Goldstein","year":"1986","journal-title":"J Trauma."},{"issue":"5","key":"bib2-20230720","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1097\/BOT.0b013e3181caa21e","article-title":"Elevated body mass index increases early complications of surgical treatment of pelvic ring injuries","volume":"24","author":"Sems","year":"2010","journal-title":"J Orthop Trauma."},{"issue":"7","key":"bib3-20230720","doi-asserted-by":"crossref","first-page":"e245","DOI":"10.1097\/BOT.0000000000001170","article-title":"Predictors of unplanned reoperation after operative treatment of pelvic ring injuries","volume":"32","author":"Ochenjele","year":"2018","journal-title":"J Orthop Trauma."},{"issue":"3","key":"bib4-20230720","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","article-title":"Early results of percutaneous iliosacral screws placed with the patient in the supine position","volume":"9","author":"Routt","year":"1995","journal-title":"J Orthop Trauma."},{"issue":"6","key":"bib5-20230720","doi-asserted-by":"crossref","first-page":"1502","DOI":"10.1097\/TA.0b013e318246efe5","article-title":"Osseous fixation pathways in pelvic and acetabular fracture surgery: osteology, radiology, and clinical applications","volume":"72","author":"Bishop","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"bib6-20230720","doi-asserted-by":"crossref","first-page":"8","DOI":"10.5435\/00124635-201201000-00002","article-title":"Variations in sacral morphology and implications for iliosacral screw fixation","volume":"20","author":"Miller","year":"2012","journal-title":"JAAOS."},{"key":"bib7-20230720","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s10195-015-0363-x","article-title":"Correlating preoperative imaging with intra-operative fluoroscopy in iliosacral screw placement","volume":"16","author":"Eastman","year":"2015","journal-title":"J Orthop Trauma."},{"key":"bib8-20230720","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/BOT.0b013e3181e47fad","article-title":"Transiliac-transsacral screws for posterior pelvic stabilization","volume":"25","author":"Gardner","year":"2011","journal-title":"J Orthop Trauma."},{"issue":"8","key":"bib9-20230720","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1097\/00005131-199711000-00007","article-title":"Iliosacral screw fixation: early complications of the percutaneous technique","volume":"11","author":"Routt","year":"1997","journal-title":"J Orthop Trauma."},{"issue":"2","key":"bib10-20230720","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.otsr.2016.12.002","article-title":"Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions","volume":"103","author":"Elzohairy","year":"2017","journal-title":"Orthop Traumatol Surg Res."},{"key":"bib11-20230720","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.ocl.2015.06.005","article-title":"Percutaneous sacroiliac screw fixation of the posterior pelvic ring","volume":"46","author":"Iorio","year":"2015","journal-title":"Orthop Clin North Am."},{"issue":"6","key":"bib12-20230720","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/00005131-200307000-00001","article-title":"Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does poeterior injury pattern predict fixation failure?","volume":"17","author":"Griffin","year":"2003","journal-title":"J Orthop Trauma."},{"key":"bib13-20230720","doi-asserted-by":"crossref","first-page":"S273","DOI":"10.1016\/j.otsr.2013.03.002","article-title":"Percutaneous iliosacral screw fixation in unstable pelvic ring lesions: the interest of O-arm CT-guided navigation","volume":"99s","author":"Coste","year":"2013","journal-title":"Orthop Traumatol Surg Res."},{"key":"bib14-20230720","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.injury.2012.09.017","article-title":"Intra-operative computed tomography with integrated navigation in percutaneous iliosacral screwing","volume":"44","author":"Peng","year":"2013","journal-title":"Injury."},{"key":"bib15-20230720","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1186\/1471-2474-11-153","article-title":"2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries\u2014a case series","volume":"11","author":"Gras","year":"2010","journal-title":"BMC Musculocutaneous Disord."},{"issue":"5","key":"bib16-20230720","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1302\/0301-620X.98B5.36287","article-title":"Placement of iliosacral screws using 3D image-guided (O-arm) technology and stealth navigation comparison with traditional fluoroscopy","volume":"98-B","author":"Theologis","year":"2016","journal-title":"Bone Joint J."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00601","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:44:56Z","timestamp":1787751896000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00601"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.19.00601","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}