{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:47:26Z","timestamp":1787755646736,"version":"build-2784847793"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>We present the results of 3 cases followed up for a minimum period of 4.5 years of revision total hip arthroplasty using a metal acetabular shell with retention of a well-fixed monoblock femoral component by inserting a dual mobility polyethylene bearing onto the femoral head in situ.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This is the first case series to use this technique to address acetabular osteolysis and avoid removing a well-fixed monoblock femoral component at the time of revision surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.19.00641","type":"journal-article","created":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T11:00:07Z","timestamp":1593601207000},"page":"e19.00641-e19.00641","source":"Crossref","is-referenced-by-count":0,"title":["Retention of Monoblock Femoral Components Using a Dual Mobility Bearing"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1926-4869","authenticated-orcid":false,"given":"Manish","family":"Kiran","sequence":"first","affiliation":[{"name":"Department of Trauma and Orthopaedics, Royal Liverpool and Broadgreen University Hospitals NHS Trust, Liverpool, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0211-1383","authenticated-orcid":false,"given":"Viju","family":"Peter","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, Royal Liverpool and Broadgreen University Hospitals NHS Trust, Liverpool, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"issue":"4","key":"bib1-20230720","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/00004623-200704000-00012","article-title":"Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030","volume":"89","author":"Kurtz","year":"2007","journal-title":"J Bone Joint Surg Am."},{"issue":"6 suppl 2","key":"bib4-20230720","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.arth.2006.05.008","article-title":"The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects","volume":"21","author":"Sporer","year":"2006","journal-title":"J Arthroplasty."},{"key":"bib5-20230720","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/0883-5403(94)90135-X","article-title":"Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation","volume":"9","author":"Paprosky","year":"1994","journal-title":"J Arthroplasty."},{"key":"bib6-20230720","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.arth.2007.08.019","article-title":"Management of severe bone loss in acetabular revision using a trabecular metal shell","volume":"23","author":"Flecher","year":"2008","journal-title":"J Arthroplasty."},{"key":"bib7-20230720","doi-asserted-by":"crossref","first-page":"2318","DOI":"10.1007\/s11999-009-0772-3","article-title":"Trabecular metal cups for acetabular defects with 50% or less host bone","volume":"467","author":"Lakstein","year":"2009","journal-title":"Clin Orthop Relat Res."},{"issue":"2","key":"bib8-20230720","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1007\/s11999-014-3861-x","article-title":"Continued good results with modular trabecular metal augments for acetabular defects in hip arthroplasty at 7 to 11 years","volume":"473","author":"Whitehouse","year":"2015","journal-title":"Clin Orthop Relat Res."},{"issue":"4","key":"bib9-20230720","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1302\/0301-620X.91B4.21933","article-title":"Charnley low-frictional torque arthroplasty: follow-up for 30 to 40 years","volume":"91","author":"Wroblewski","year":"2009","journal-title":"J Bone Joint Surg Br."},{"key":"bib10-20230720","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1142\/S0218957799000269","article-title":"Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterial","volume":"3","author":"Zhang","year":"1999","journal-title":"J Musculoskelet Res."},{"issue":"7","key":"bib11-20230720","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1302\/0301-620X.91B7.22181","article-title":"Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabularcomponent for severe acetabular bone loss associated with pelvic discontinuity","volume":"91","author":"Kosashvili","year":"2009","journal-title":"J Bone Joint Surg Br."},{"key":"bib12-20230720","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1177\/112070000801800104","article-title":"Porous tantalum uncemented acetabular shells in revision total hip replacement: two to four year clinical and radiographic results","volume":"18","author":"Kim","year":"2008","journal-title":"Hip Int."},{"issue":"3","key":"bib13-20230720","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.arth.2010.01.106","article-title":"Early results of 827 trabecular metal revision shells in acetabular revision","volume":"26","author":"Skytt\u00e4","year":"2011","journal-title":"J Arthroplasty."},{"key":"bib14-20230720","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1016\/j.arth.2005.01.023","article-title":"Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips","volume":"20","author":"Unger","year":"2005","journal-title":"J Arthroplasty."},{"issue":"2","key":"bib15-20230720","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/s11999-007-0047-9","article-title":"Dual mobility cemented cups have low dislocation rates in THA revisions","volume":"466","author":"Langlais","year":"2008","journal-title":"Clin Orthop."},{"issue":"6","key":"bib16-20230720","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.otsr.2009.04.016","article-title":"Prevention of dislocation in total hip revision surgery using a dual mobility design","volume":"95","author":"Philippot","year":"2009","journal-title":"Orthop Traumatol Surg Res."},{"issue":"1","key":"bib17-20230720","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.otsr.2010.08.003","article-title":"Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up","volume":"97","author":"Leiber-Wackenheim","year":"2011","journal-title":"Orthop Traumatol Surg Res."},{"issue":"6","key":"bib18-20230720","doi-asserted-by":"crossref","first-page":"566","DOI":"10.3109\/17453674.2012.742395","article-title":"Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation 228 patients from the Swedish Hip Arthroplasty Register","volume":"83","author":"Hailer","year":"2012","journal-title":"Acta Orthop."},{"issue":"4","key":"bib19-20230720","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1016\/j.arth.2014.10.034","article-title":"Can dual mobility cups prevent dislocation in all situations after revision total HipArthroplasty?","volume":"30","author":"Wegrzyn","year":"2015","journal-title":"J Arthroplasty."},{"issue":"5","key":"bib20-20230720","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1302\/0301-620X.94B5.27876","article-title":"The double-mobility acetabular component in revision total hip replacement the United Kingdom experience","volume":"94","author":"Vasukutty","year":"2012","journal-title":"J Bone Joint Surg Br"}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00641","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:46:45Z","timestamp":1787752005000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.19.00641"}},"subtitle":["A Report of 3 Cases"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":18,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.19.00641","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}