{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:45:24Z","timestamp":1787755524522,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 58-year-old man sustained multiple right foot injuries during a motor vehicle accident that included a calcaneus fracture requiring open reduction and internal fixation (ORIF). The procedure was complicated by a prominent implant inferior to the sustentaculum, which necessitated a return to the operating room. Commonly used fluoroscopic views do not adequately image this area. A cadaveric study was undertaken to identify the optimal 2-dimensional fluoroscopic view that evaluates prominent implants at the medial calcaneus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The sustentaculum tunnel view gives a reliable image of prominent medial implants, and use of this technique may limit complications after calcaneus ORIF.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.20.00161","type":"journal-article","created":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T11:00:59Z","timestamp":1597230059000},"page":"e20.00161","source":"Crossref","is-referenced-by-count":2,"title":["Harris Heel View is Inadequate to Visualize Screw Prominence of the Medial Calcaneus"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2911-2490","authenticated-orcid":false,"given":"Michael M.","family":"Hadeed","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Virginia, Charlottesville, Virginia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7099-2760","authenticated-orcid":false,"given":"Brenton R.","family":"Jennewine","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Virginia, Charlottesville, Virginia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8343-0908","authenticated-orcid":false,"given":"Jose","family":"George","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Virginia, Charlottesville, Virginia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0868-078X","authenticated-orcid":false,"given":"Seth R.","family":"Yarboro","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Virginia, Charlottesville, Virginia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"key":"bib1-20230720","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.foot.2009.05.001","article-title":"The epidemiology of calcaneal fractures","volume":"19","author":"Mitchell","year":"2009","journal-title":"Foot."},{"key":"bib2-20230720","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/00005131-200201000-00006","article-title":"Percutaneous pin placement in the medial calcaneus: is anywhere safe?","volume":"16","author":"Casey","year":"2000","journal-title":"J Orthop Trauma."},{"key":"bib4-20230720","first-page":"768","article-title":"Intraoperative 3D imaging in calcaneal fracture care \u2013 clinical implications and decision making","volume":"66","author":"Geerling","year":"2009","journal-title":"J Trauma."},{"key":"bib5-20230720","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2106\/JBJS.L.01220","article-title":"Intraoperative three-dimensional imaging in the treatment of calcaneal fractures","volume":"96","author":"Franke","year":"2014","journal-title":"J Bone Joint Surg Am."},{"key":"bib6-20230720","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/01.bot.0000151822.10254.db","article-title":"Intraoperative three-dimensional imaging with motorized mobile c-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care","volume":"19","author":"Richter","year":"2005","journal-title":"J Orthop Trauma."},{"key":"bib7-20230720","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.3113\/FAI.2007.1165","article-title":"Three-dimensional fluoroscopy for evaluation of articular reduction and screw placement in calcaneal fractures","volume":"28","author":"Kendoff","year":"2007","journal-title":"Foot Ankle Int."},{"key":"bib8-20230720","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/BOT.0b013e31819867f6","article-title":"Intraoperative 3-dimensional imaging in foot and ankle trauma\u2014experience with a second-generation device (ARCADIS-3D)","volume":"23","author":"Richter","year":"2009","journal-title":"J Orthop Trauma."},{"key":"bib9-20230720","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.ejrad.2019.01.013","article-title":"The correlation between intraoperative 2D- and 3D fluoroscopy with postoperative CT-scans in the treatment of calcaneal fractures","volume":"112","author":"Beerekamp","year":"2019","journal-title":"Eur J Radiol."},{"key":"bib10-20230720","doi-asserted-by":"crossref","first-page":"2864","DOI":"10.1016\/j.injury.2017.10.035","article-title":"2D and 3D assessment of sustentaculum tali screw fixation with or without screw targeting clamp","volume":"48","author":"De Boer","year":"2017","journal-title":"Injury."},{"key":"bib11-20230720","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1177\/1071100712467617","article-title":"Assessing accuracy of sustentaculum screw placement during calcaneal fixation","volume":"34","author":"Gitajin","year":"2013","journal-title":"Foot Ankle Int."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00161","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:44:26Z","timestamp":1787751866000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00161"}},"subtitle":["A Case Report and Cadaveric Evaluation"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":10,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.20.00161","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}