{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:34:45Z","timestamp":1787754885545,"version":"build-2784847793"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 12-year-old male patient sustained a multisegmental both-bone forearm fracture. Definitive stabilization was ulna intramedullary pinning, with stainless steel plating of the radius followed by a titanium plate stacked atop and extending internal fixation. Currently, 36 months after surgery, he experiences no limitations or complications. All hardware remains in situ.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>We believe this is the first description of different material plates in direct contact, of stacked plates, and of 1 plate extending another's fixation. No adverse effects developed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.20.00325","type":"journal-article","created":{"date-parts":[[2020,11,5]],"date-time":"2020-11-05T15:00:11Z","timestamp":1604588411000},"page":"e20.00325-e20.00325","source":"Crossref","is-referenced-by-count":3,"title":["Pediatric Open Both-Bone Forearm Fracture Stabilized with Titanium and Stainless Steel Stacked Extension Internal Plating"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7065-0656","authenticated-orcid":false,"given":"Jason Shih","family":"Hoellwarth","sequence":"first","affiliation":[{"name":"Department of Pediatric Orthopaedics, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4931-0216","authenticated-orcid":false,"given":"Brian P.","family":"Scannell","sequence":"additional","affiliation":[{"name":"OrthoCarolina and Atrium Musculoskeletal Institute, Charlotte, North Carolina"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"key":"bib1-20230720","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.pmatsci.2008.06.004","article-title":"Ti based biomaterials, the ultimate choice for orthopaedic implants\u2014a review","volume":"54","author":"Geetha","year":"2009","journal-title":"Prog Mater Sci."},{"key":"bib2-20230720","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1097\/01.TA.0000060999.54287.39","article-title":"The effect of implant overlap on the mechanical properties of the femur","volume":"54","author":"Harris","year":"2003","journal-title":"J Trauma."},{"key":"bib3-20230720","first-page":"5325","article-title":"Treatment of diaphyseal forearm fractures in children","volume":"6","author":"Vopat","year":"2014","journal-title":"Orthop Rev."},{"key":"bib4-20230720","doi-asserted-by":"crossref","first-page":"780","DOI":"10.5435\/JAAOS-D-15-00151","article-title":"Pediatric and adolescent forearm fractures: current controversies and treatment recommendations","volume":"24","author":"Pace","year":"2016","journal-title":"J Am Acad Orthop Surg."},{"key":"bib5-20230720","doi-asserted-by":"crossref","first-page":"49","DOI":"10.5435\/00124635-201101000-00006","article-title":"Acute compartment syndrome of the upper extremity","volume":"19","author":"Prasarn","year":"2011","journal-title":"J Am Acad Orthop Surg."},{"key":"bib6-20230720","doi-asserted-by":"crossref","first-page":"212","DOI":"10.5435\/00124635-200305000-00008","article-title":"Open fractures: evaluation and management","volume":"11","author":"Zalavras","year":"2003","journal-title":"J Am Acad Orthop Surg."},{"key":"bib7-20230720","doi-asserted-by":"crossref","first-page":"230","DOI":"10.5435\/JAAOS-D-16-00127","article-title":"Management of open tibial shaft fractures: does the timing of surgery affect outcomes?","volume":"25","author":"Duyos","year":"2017","journal-title":"J Am Acad Orthop Surg."},{"key":"bib8-20230720","doi-asserted-by":"crossref","first-page":"e28","DOI":"10.2106\/JBJS.ST.O.00004","article-title":"Open reduction and internal fixation of both-bones forearm fractures","volume":"5","author":"Nauth","year":"2015","journal-title":"JBJS Essent Surg Tech."},{"key":"bib9-20230720","doi-asserted-by":"crossref","first-page":"379","DOI":"10.5435\/00124635-200211000-00001","article-title":"Timing of closure of open fractures","volume":"10","author":"Weitz-Marshall","year":"2002","journal-title":"J Am Acad Orthop Surg."},{"key":"bib10-20230720","doi-asserted-by":"crossref","first-page":"40","DOI":"10.2174\/1877610801002010040","article-title":"Biomedical implants: corrosion and its prevention\u2014a review","volume":"2","author":"Manivasagam","year":"2010","journal-title":"Recent Patents Corrosion Sci."},{"key":"bib11-20230720","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1002\/jbm.820080609","article-title":"Couple corrosion among alloys for skeletal prostheses","volume":"8","author":"Rostoker","year":"1974","journal-title":"J Biomed Mater Res."},{"key":"bib12-20230720","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s10856-005-5922-x","article-title":"The influence of passivation and electropolishing on the performance of medical grade stainless steels in static and fatigue loading","volume":"16","author":"Weldon","year":"2005","journal-title":"J Mater Sci Mater Med."},{"key":"bib13-20230720","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/j.msec.2019.04.064","article-title":"Review on titanium and titanium based alloys as biomaterials for orthopaedic applications","volume":"102","author":"Kaur","year":"2019","journal-title":"Mater Sci Eng C Mater Biol Appl."},{"key":"bib14-20230720","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.ocl.2019.02.001","article-title":"Trunnion corrosion in total hip arthroplasty-basic concepts","volume":"50","author":"Urish","year":"2019","journal-title":"Orthop Clin North Am."},{"key":"bib15-20230720","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1002\/jbm.820090417","article-title":"The use of dissimilar metals in surgery","volume":"9","author":"Mears","year":"1975","journal-title":"J Biomed Mater Res."},{"key":"bib16-20230720","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1177\/1938640011422597","article-title":"Combining dissimilar metals in orthopaedic implants: revisited","volume":"4","author":"Zartman","year":"2011","journal-title":"Foot Ankle Spec."},{"key":"bib18-20230720","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.2106\/00004623-199810000-00027","article-title":"Current concepts review. Corrosion of metal orthopaedic implants","volume":"80","author":"Cohen","year":"1998","journal-title":"J Bone Joint Surg Am."},{"key":"bib19-20230720","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.spinee.2003.12.004","article-title":"Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?","volume":"4","author":"Serhan","year":"2004","journal-title":"Spine J."},{"key":"bib20-20230720","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.injury.2007.07.015","article-title":"Should the galvanic combination of titanium and stainless steel surgical implants be avoided?","volume":"39","author":"H\u00f8l","year":"2008","journal-title":"Injury."},{"key":"bib21-20230720","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1007\/s00402-007-0396-6","article-title":"Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant","volume":"128","author":"Erhardt","year":"2008","journal-title":"Arch Orthop Trauma Surg."},{"key":"bib22-20230720","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s00113-009-1665-3","article-title":"Results and complications in the treatment of periprosthetic femur fractures with a locked plate system [in German]","volume":"113","author":"Pressmar","year":"2010","journal-title":"Unfallchirurg."},{"key":"bib23-20230720","doi-asserted-by":"crossref","first-page":"454","DOI":"10.4103\/0019-5413.118200","article-title":"Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures","volume":"47","author":"El-Zayat","year":"2013","journal-title":"Indian J Orthop."},{"key":"bib24-20230720","doi-asserted-by":"crossref","first-page":"e1175","DOI":"10.3928\/01477447-20130821-21","article-title":"Mixing implants of differing metallic composition in the treatment of upper-extremity fractures","volume":"36","author":"Acevedo","year":"2013","journal-title":"Orthopedics."},{"key":"bib25-20230720","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1016\/j.jhsa.2015.03.030","article-title":"An overview of internal fixation implant metallurgy and galvanic corrosion effects","volume":"40","author":"Koh","year":"2015","journal-title":"J Hand Surg Am."},{"key":"bib26-20230720","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1111\/j.1532-950X.2009.00587.x","article-title":"Biomechanical analysis of stacked plating techniques to stabilize distal radial fractures in small dogs: stacked plating techniques for distal radial fractures","volume":"38","author":"Rose","year":"2009","journal-title":"Vet Surg."},{"key":"bib27-20230720","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.2106\/JBJS.J.00137","article-title":"American Academy of Orthopaedic Surgeons clinical practice guideline on treatment of pediatric diaphyseal femur fracture","volume":"92","author":"Kocher","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"bib28-20230720","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1097\/01241398-199101000-00014","article-title":"Metal removal in a pediatric population: benign procedure or necessary evil?","volume":"11","author":"Schmalzried","year":"1991","journal-title":"J Pediatr Orthop."},{"key":"bib29-20230720","first-page":"107","article-title":"Metallic implant removal in children","volume":"25","author":"Peterson","year":"2005","journal-title":"J Pediatr Orthop."},{"key":"bib30-20230720","doi-asserted-by":"crossref","first-page":"113","DOI":"10.5435\/00124635-200602000-00006","article-title":"Hardware removal: indications and expectations","volume":"14","author":"Busam","year":"2006","journal-title":"J Am Acad Orthop Surg."},{"key":"bib31-20230720","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1097\/01.bpo.0000214924.02939.62","article-title":"Orthopaedic implants in children: survey results regarding routine removal by the pediatric and nonpediatric specialists","volume":"26","author":"Loder","year":"2006","journal-title":"J Pediatr Orthop."},{"key":"bib32-20230720","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1302\/0301-620X.94B1.27155","article-title":"Retention of forearm plates: risks and benefits in a paediatric population","volume":"94","author":"Clement","year":"2012","journal-title":"J Bone Joint Surg Br."},{"key":"bib33-20230720","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1302\/0301-620X.73B3.1670441","article-title":"Refracture after the removal of plates from the forearm. An avoidable complication","volume":"73","author":"Rosson","year":"1991","journal-title":"J Bone Joint Surg Br."},{"key":"bib34-20230720","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1016\/j.injury.2005.09.006","article-title":"The removal of forearm plates in children","volume":"36","author":"Kim","year":"2005","journal-title":"Injury."},{"key":"bib35-20230720","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1097\/BPO.0b013e3181875b60","article-title":"Evidence-based analysis of removal of orthopaedic implants in the pediatric population","volume":"28","author":"Raney","year":"2008","journal-title":"J Pediatr Orthop."},{"key":"bib36-20230720","doi-asserted-by":"crossref","first-page":"e19010","DOI":"10.1097\/MD.0000000000019010","article-title":"Complications of hardware removal in pediatric upper limb surgery: a retrospective single-center study of 317 patients","volume":"99","author":"Scheider","year":"2020","journal-title":"Medicine (Baltimore)."},{"key":"bib37-20230720","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1097\/BPB.0b013e32832d5da2","article-title":"Outcomes analysis after routine removal of implants in healthy pediatric patients","volume":"18","author":"Chu","year":"2009","journal-title":"J Pediatr Orthop B."},{"key":"bib38-20230720","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/s00068-013-0286-2","article-title":"Implant removal in children","volume":"39","author":"Schmittenbecher","year":"2013","journal-title":"Eur J Trauma Emerg Surg."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00325","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:34:25Z","timestamp":1787751265000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00325"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":37,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.20.00325","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}