{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:23:01Z","timestamp":1787754181600,"version":"build-2784847793"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>Intraprosthetic dislocation, a rare complication of modular dual-mobility hip replacements, occurs when the polyethylene component becomes dislodged. Our patient sustained an intraprosthetic dislocation with subsequent implant migration to the posterior thigh. In an anterior approach revision surgery at an outside institution, the component was unable to be located. Subsequent imaging revealed marked implant migration. Computed tomography (CT)-guided needle localization was used to facilitate component removal.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In the presence of different surgical approaches, dissociated polyethylene components may migrate to anatomic compartments distinct from the approach of implantation. CT and needle localization may be used to facilitate component removal.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.20.00400","type":"journal-article","created":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T14:08:51Z","timestamp":1621260531000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Disassociation of an Anteriorly Implanted Dual-Mobility Component with Migration to the Distal Posterior Thigh"],"prefix":"10.2106","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5389-7956","authenticated-orcid":false,"given":"Luke W.","family":"Anliker","sequence":"first","affiliation":[{"name":"Hinsdale Orthopaedics, Hinsdale, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3517-3353","authenticated-orcid":false,"given":"Jonathan M.","family":"Tresley","sequence":"additional","affiliation":[{"name":"Advocate Good Samaritan Hospital, Downers Grove, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9956-1091","authenticated-orcid":false,"given":"Justin M.","family":"LaReau","sequence":"additional","affiliation":[{"name":"Hinsdale Orthopaedics, Hinsdale, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,4]]},"reference":[{"key":"bib1-20240805","doi-asserted-by":"crossref","first-page":"3329","DOI":"10.1016\/j.arth.2018.05.040","article-title":"Does surgeon volume affect outcomes following primary total hip arthroplasty? A systemic review","volume":"33","author":"Malik","year":"2018","journal-title":"J Arthroplasty."},{"key":"bib2-20240805","doi-asserted-by":"crossref","first-page":"e111","DOI":"10.1016\/S2665-9913(19)30045-1","article-title":"Risk factors for dislocation after primary total hip replacement: a systematic review and meta-analysis of 125 studies involving approximately five million hip replacements","volume":"1","author":"Kunutsor","year":"2019","journal-title":"Lancet Rheum."},{"key":"bib3-20240805","doi-asserted-by":"crossref","first-page":"180","DOI":"10.5312\/wjo.v5.i3.180","article-title":"Dual mobility cups in total hip arthroplasty","volume":"5","author":"De Martino","year":"2014","journal-title":"World J Orthop."},{"key":"bib4-20240805","first-page":"473","article-title":"Dual-mobility acetabular components in total hip arthroplasty","volume":"42","author":"McArthur","year":"2013","journal-title":"Am J Orthop."},{"key":"bib5-20240805","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1007\/s11999-012-2639-2","article-title":"Intraprosthetic dislocation: a specific complication of the dual-mobility system","volume":"471","author":"Philippot","year":"2013","journal-title":"Clin Orthop Relat Res."},{"key":"bib6-20240805","first-page":"185","article-title":"Total hip arthroplasty dislocations are more complex than they appear: a case report of intraprosthetic dislocation of an anatomic dual-mobility implant after closed reduction","volume":"16","author":"Waddell","year":"2016","journal-title":"Oschner J."},{"key":"bib7-20240805","doi-asserted-by":"crossref","first-page":"e1124","DOI":"10.3928\/01477447-20141124-90","article-title":"Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA","volume":"37","author":"Odland","year":"2014","journal-title":"Orthopedics."},{"key":"bib8-20240805","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/00003086-199205000-00018","article-title":"Dissociation of modular hip arthroplasty components after dislocation: a report of three cases at differing dissociation levels","volume":"278","author":"Star","year":"1992","journal-title":"Clin Orthop."},{"key":"bib9-20240805","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.2106\/JBJS.CC.N.00137","article-title":"Intraprosthetic dislocation of dual-mobility bearings associated with closed reduction","volume":"5","author":"Cvetanovich","year":"2015","journal-title":"JBJS Case Connect."},{"key":"bib10-20240805","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1007\/s11999-015-4381-z","article-title":"Dissociation and intrapelvic entrapment of the dual-mobility polyethylene component","volume":"474","author":"Fehring","year":"2016","journal-title":"Clin Orthop Relat Res."},{"key":"bib11-20240805","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/01.blo.0000238859.46615.34","article-title":"Muscle damage during MIS total hip arthroplasty","volume":"453","author":"Meneghini","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"bib12-20240805","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1302\/0301-620X.98B8.37178","article-title":"Greater inadvertent muscle damage in direct anterior approach when compared with the direct superior approach for total hip arthroplasty","volume":"98-B","author":"Amanatullah","year":"2016","journal-title":"Bone Joint J."},{"key":"bib13-20240805","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.arth.2020.07.030","article-title":"Anterior revision hip arthroplasty is associated with higher wound complications but fewer dislocations compared to posterior revision hip surgery","volume":"36","author":"Kurkis","year":"2021","journal-title":"J Arthroplasty."},{"key":"bib14-20240805","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.injury.2008.06.003","article-title":"Technique of k-wire localization and removal using ultrasound guidance","volume":"39","author":"Queally","year":"2008","journal-title":"Inj Extra."},{"key":"bib15-20240805","doi-asserted-by":"crossref","first-page":"e570","DOI":"10.3928\/01477447-20110714-03","article-title":"Intraoperative ultrasound assistance for excision of impalpable musculoskeletal soft tissue tumors","volume":"34","author":"Farfalli","year":"2011","journal-title":"Orthopedics."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00400","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:23:50Z","timestamp":1787750630000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00400"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":15,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.20.00400","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}