{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:45:49Z","timestamp":1787755549477,"version":"build-2784847793"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>An 11-year-old female patient underwent bilateral in situ fixation for slipped capital femoral epiphyses using single, cannulated, stainless steel screws. She presented 12 years later with a large osteolytic lesion of the proximal femur, which only involved 1 side. Histological evaluation showed a foreign-body reaction and synovial lining. Infection was ruled out and dynamic hip screw stabilization, and bone grafting were performed. The bone graft healed, and the hardware was removed to prevent a similar reaction. In retrospect, postoperative radiographs at 7 weeks showed subtle osteolysis along the screw.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Intra-articular drilling, vertical screw placement into the posterior epiphysis, and the prominent screw head may have led to this unexpected complication.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.20.00408","type":"journal-article","created":{"date-parts":[[2020,12,21]],"date-time":"2020-12-21T15:03:53Z","timestamp":1608563033000},"page":"e20.00408-e20.00408","source":"Crossref","is-referenced-by-count":1,"title":["Proximal Femoral Bone Cyst After Single Screw Fixation for Slipped Capital Femoral Epiphysis"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1226-3513","authenticated-orcid":false,"given":"Matthew A.","family":"Siegel","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5854-4006","authenticated-orcid":false,"given":"Jason Y.","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2031-0201","authenticated-orcid":false,"given":"Maged R.","family":"Hanna","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Toledo, Toledo, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1173-4435","authenticated-orcid":false,"given":"Yasser R.","family":"Farid","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"issue":"7","key":"bib1-20230719","first-page":"1515","article-title":"Early osteolysis following second-generation metal-on-metal hip replacement","volume":"87","author":"Park","year":"2005","journal-title":"J Bone Joint Surg Am."},{"issue":"1","key":"bib2-20230719","doi-asserted-by":"crossref","first-page":"28","DOI":"10.2106\/JBJS.A.02039pp","article-title":"Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study","volume":"87","author":"Willert","year":"2005","journal-title":"J Bone Joint Surg Am."},{"issue":"1","key":"bib3-20230719","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1034\/j.1600-0536.2003.480108_4.x","article-title":"Metal allergy resurfaces in failed hip endoprostheses","volume":"48","author":"Antony","year":"2003","journal-title":"Contact Dermatitis."},{"issue":"3","key":"bib4-20230719","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1111\/j.1445-2197.2007.04390.x","article-title":"Osteolysis in patients with a metal-on-metal hip arthroplasty","volume":"78","author":"Carr","year":"2008","journal-title":"ANZ J Surg."},{"issue":"8 suppl 3","key":"bib5-20230719","first-page":"29","article-title":"An American experience with metal-on-metal total hip arthroplasties: a 7-year follow-up study","volume":"19","author":"Long","year":"2004","journal-title":"J Arthroplasty."},{"issue":"suppl 2","key":"bib6-20230719","first-page":"118","article-title":"A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian academic centers","volume":"93","year":"2011","journal-title":"J Bone Joint Surg Am."},{"issue":"4","key":"bib7-20230719","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.arth.2010.05.030","article-title":"\u201cAsymptomatic\u201d pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study","volume":"26","author":"Kwon","year":"2011","journal-title":"J Arthroplasty."},{"issue":"9","key":"bib8-20230719","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/j.jhsa.2017.06.009","article-title":"Making sense of metal allergy and hypersensitivity to metallic implants in relation to hand surgery","volume":"42","author":"Christensen","year":"2017","journal-title":"J Hand Surg."},{"issue":"1","key":"bib9-20230719","first-page":"34","article-title":"The effects on bone cells of metal ions released from orthopaedic implants. A review","volume":"10","author":"Sansone","year":"2013","journal-title":"Clin Cases Miner Bone Metab."},{"key":"bib10-20230719","first-page":"6","article-title":"Posttraumatic cyst-like lesions of cortical bone in children","volume":"76","author":"Asrian","year":"2010","journal-title":"Acta Orthop Belg."},{"issue":"6","key":"bib11-20230719","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/01.mej.0000228443.17781.bb","article-title":"Post-traumatic cortical cysts in paediatric fractures: is it a concern for emergency doctors? A report of three cases","volume":"14","author":"Houshian","year":"2007","journal-title":"Eur J Emerg Med."},{"issue":"2","key":"bib12-20230719","doi-asserted-by":"crossref","first-page":"172","DOI":"10.5312\/wjo.v6.i2.172","article-title":"Biological response to prosthetic debris","volume":"6","author":"Bitar","year":"2015","journal-title":"World J Orthop."},{"issue":"26","key":"bib13-20230719","doi-asserted-by":"crossref","first-page":"5296","DOI":"10.1016\/j.biomaterials.2005.01.055","article-title":"The quantification of cellular viability and inflammatory response to stainless steel alloys","volume":"26","author":"Bailey","year":"2005","journal-title":"Biomaterials."},{"issue":"4","key":"bib14-20230719","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1615\/JLongTermEffMedImplants.2014010564","article-title":"Innate immune reactions in septic and aseptic osteolysis around hip implants","volume":"24","author":"Pajarinen","year":"2014","journal-title":"J Long Term Eff Med Implants."},{"key":"bib15-20230719","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1097\/01241398-199313050-00010","article-title":"Windshield-wiper loosening: action of in situ screw fixation of slipped capital femoral epiphysis","volume":"13","author":"Maletis","year":"1993","journal-title":"J Pediatr Orthop."},{"key":"bib16-20230719","doi-asserted-by":"crossref","first-page":"810","DOI":"10.2106\/00004623-199274060-00002","article-title":"Slipped capital femoral epiphysis. A prospective study of fixation with a single screw [published erratum, J Bone Joint Surg Am. 1992;74:1274]","volume":"74","author":"Aronson","year":"1992","journal-title":"J Bone Joint Surg Am."},{"key":"bib17-20230719","doi-asserted-by":"crossref","first-page":"799","DOI":"10.2106\/00004623-199274060-00001","article-title":"Fixation with a single screw for slipped capital femoral epiphysis [published erratum appears in J Bone Joint Surg Am. 1993;75:1255]","volume":"74","author":"Ward","year":"1992","journal-title":"J Bone Joint Surg Am."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00408","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:44:42Z","timestamp":1787751882000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00408"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":17,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.20.00408","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}