{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:40:02Z","timestamp":1787755202920,"version":"build-2784847793"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 68-year-old woman sustained an isolated type III left coronoid fracture after mechanical ground-level fall. The patient underwent left elbow arthroscopy with minimally invasive arthroscopic reduction and internal fixation of the coronoid fracture using Arthrex Mini TightRope. The patient achieved successful elbow stabilization with a postoperative Mayo Elbow Score of 100.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>We present a case report of a novel technique in coronoid fracture management with stable fixation, minimal soft-tissue violation, and restoration of highly functional elbow range of motion. Minimal soft-tissue violation with use of arthroscopy and suture button was the key element in successful surgical treatment and outcome.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.20.00715","type":"journal-article","created":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T23:00:25Z","timestamp":1643670025000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Arthroscopic Repair of a Coronoid Process Fracture"],"prefix":"10.2106","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5501-3114","authenticated-orcid":false,"given":"Ali S.","family":"Noorzad","sequence":"first","affiliation":[{"name":"Cedars-Sinai Medical Center, Los Angeles, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zohal","family":"Jelani","sequence":"additional","affiliation":[{"name":"University of San Francisco Fresno, Fresno, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"Rinaldi","sequence":"additional","affiliation":[{"name":"Florida International University, Herbert Wertheim College of Medicine, Miami, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachab","family":"Abdie","sequence":"additional","affiliation":[{"name":"Villanova University, Villanova, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4293-6662","authenticated-orcid":false,"given":"Bashir A.","family":"Zikria","sequence":"additional","affiliation":[{"name":"Johns Hopkins Medicine, Baltimore, Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,7]]},"reference":[{"issue":"4","key":"bib1-20240731","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.jse.2004.11.005","article-title":"Role of the coronoid process in varus osteoarticular stability of the elbow","volume":"14","author":"Hull","year":"2005","journal-title":"J Shoulder Elbow Surg."},{"issue":"9","key":"bib2-20240731","doi-asserted-by":"crossref","first-page":"519","DOI":"10.5435\/00124635-200809000-00004","article-title":"Coronoid process fracture","volume":"16","author":"Steinmann","year":"2008","journal-title":"J Am Acad Orthop Surg."},{"issue":"12","key":"bib3-20240731","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.2106\/00004623-200012000-00009","article-title":"The role of the coronoid process in elbow stability. A biomechanical analysis of axial loading","volume":"82","author":"Closkey","year":"2000","journal-title":"J Bone Joint Surg Am."},{"issue":"265","key":"bib4-20240731","first-page":"187","article-title":"Valgus stability of the elbow. A definition of primary and secondary constraints","author":"Morrey","year":"1991","journal-title":"Clin Orthop Relat Res."},{"issue":"3","key":"bib5-20240731","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S1058-2746(02)86803-3","article-title":"The proximal ulna: an anatomic study with relevance to olecranon osteotomy and fracture fixation","volume":"12","author":"Wang","year":"2003","journal-title":"J Shoulder Elbow Surg."},{"issue":"3","key":"bib6-20240731","doi-asserted-by":"crossref","first-page":"137","DOI":"10.5435\/00124635-200903000-00003","article-title":"Terrible triad injury of the elbow: current concepts","volume":"17","author":"Mathew","year":"2009","journal-title":"J Am Acad Orthop Surg."},{"issue":"7","key":"bib7-20240731","doi-asserted-by":"crossref","first-page":"845","DOI":"10.3928\/0147-7447-19920701-09","article-title":"Classification and treatment of coronoid process fractures","volume":"15","author":"Regan","year":"1992","journal-title":"Orthopedics."},{"key":"bib8-20240731","first-page":"113","article-title":"Difficult elbow fractures: pearls and pitfalls","volume":"52","author":"O'Driscoll","year":"2003","journal-title":"Instr Course Lect."},{"issue":"5","key":"bib9-20240731","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.jse.2007.03.013","article-title":"The anteromedial facet of the coronoid process of the ulna","volume":"16","author":"Doornberg","year":"2007","journal-title":"J Shoulder Elbow Surg."},{"issue":"3","key":"bib10-20240731","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.jhsa.2004.01.005","article-title":"Surgical treatment of persistent dislocation or subluxation of the ulnohumeral joint after fracture-dislocation of the elbow","volume":"29","author":"Ring","year":"2004","journal-title":"J Hand Surg Am."},{"issue":"Pt 1","key":"bib11-20240731","first-page":"22","article-title":"Standard surgical protocol to treat elbow dislocations with radial head and coronoid fractures. Surgical technique","volume":"87","author":"McKee","year":"2005","journal-title":"J Bone Joint Surg Am."},{"issue":"4","key":"bib12-20240731","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/j.hcl.2015.06.011","article-title":"Arthroscopic management of elbow fractures","volume":"31","author":"Fink Barnes","year":"2015","journal-title":"Hand Clin."},{"issue":"10","key":"bib13-20240731","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1016\/j.arthro.2007.05.017","article-title":"Arthroscopic-assisted treatment of coronoid fractures","volume":"23","author":"Adams","year":"2007","journal-title":"Arthroscopy."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00715","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:39:16Z","timestamp":1787751556000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.20.00715"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2021,7]]},"references-count":13,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.20.00715","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7]]}}}