{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:43:17Z","timestamp":1787755397725,"version":"build-2784847793"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>The Synthes Femoral Neck System (FNS) is a relatively new device available to the market in 2019 designed to reduce complication and revision rates after femoral neck fracture stabilization. We present a 77-year-old man with Parkinson disease and avascular necrosis after femoral neck fracture initially managed with the FNS. Subsequent challenges in device removal occurred because of its propensity for bony integration, plate and locking screw welding, and screw head recess destruction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Surgeons must recognize the need for additional available equipment (e.g., burr or broken screw removal set) for successful extraction when FNS removal is required.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.22.00530","type":"journal-article","created":{"date-parts":[[2023,7,12]],"date-time":"2023-07-12T14:00:46Z","timestamp":1689170446000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Cold Welding of the Synthes Femoral Neck System Encountered at Conversion to Arthroplasty"],"prefix":"10.2106","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4079-7563","authenticated-orcid":false,"given":"Danielle F.","family":"Peterson","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Oregon Health and Science University, Portland, Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4138-2650","authenticated-orcid":false,"given":"Kathryn","family":"Schabel","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Oregon Health and Science University, Portland, Oregon"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,7]]},"reference":[{"issue":"4","key":"bib1-20240805","doi-asserted-by":"crossref","first-page":"e154","DOI":"10.5435\/JAAOS-D-20-00349","article-title":"Current trends in the evaluation and management of nondisplaced femoral neck fractures in the elderly","volume":"29","author":"Okike","year":"2021","journal-title":"J Am Acad Orthop Surg."},{"issue":"22","key":"bib2-20240805","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.2106\/JBJS.16.01247","article-title":"Nationwide analysis of femoral neck fractures in elderly patients: a receding tide","volume":"99","author":"Ju","year":"2017","journal-title":"J Bone Joint Surg Am."},{"issue":"3","key":"bib3-20240805","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1097\/BOT.0000000000000291","article-title":"Femoral neck fractures: current management","volume":"29","author":"Florschutz","year":"2015","journal-title":"J Orthop Trauma."},{"issue":"12","key":"bib4-20240805","doi-asserted-by":"crossref","first-page":"411","DOI":"10.5435\/JAAOS-D-16-00362","article-title":"Management of pediatric femoral neck fracture","volume":"26","author":"Patterson","year":"2018","journal-title":"J Am Acad Orthop Surg."},{"issue":"7","key":"bib5-20240805","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1097\/BOT.0000000000001747","article-title":"Screw fixation versus hemiarthroplasty for nondisplaced femoral neck fractures in the elderly: a cost-effectiveness analysis","volume":"34","author":"Yong","year":"2020","journal-title":"J Orthop Trauma."},{"issue":"4","key":"bib6-20240805","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.injury.2009.10.003","article-title":"Hemiarthroplasty versus internal fixation for displaced intracapsular hip fractures: a long-term follow-up of a randomised trial","volume":"41","author":"Parker","year":"2010","journal-title":"Injury."},{"issue":"12","key":"bib7-20240805","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1007\/s00402-014-2096-3","article-title":"Revision rates and cumulative financial burden in patients treated with hemiarthroplasty compared to cannulated screws after femoral neck fractures","volume":"134","author":"Shields","year":"2014","journal-title":"Arch Orthop Trauma Surg."},{"issue":"3","key":"bib8-20240805","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","article-title":"Biomechanical evaluation of the femoral neck system in unstable pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws","volume":"31","author":"Stoffel","year":"2017","journal-title":"J Orthop Trauma."},{"key":"bib10-20240805","first-page":"23","article-title":"Better stability and more predictive fixation of the femoral neck system versus two hansson pins in pauwels ii femoral neck fractures: a biomechanical study","volume":"103","author":"Schopper","year":"2021","journal-title":"Orthop Proc."},{"issue":"1","key":"bib11-20240805","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1186\/s13018-021-02517-z","article-title":"Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients","volume":"16","author":"Hu","year":"2021","journal-title":"J Orthop Surg Res."},{"issue":"1","key":"bib12-20240805","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.arth.2017.07.035","article-title":"Total hip arthroplasty after in situ fixation of minimally displaced femoral neck fractures in elderly patients","volume":"33","author":"Hernandez","year":"2018","journal-title":"J Arthroplasty."},{"issue":"4","key":"bib13-20240805","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.2329\/perio.30.1021","article-title":"The reaction of peri-implant tissues to titanium alloy and apatite-coated implants during the healing phase","volume":"30","author":"Yamada","year":"1988","journal-title":"Nihon Shishubyo Gakkai Kaishi."},{"issue":"7","key":"bib14-20240805","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1016\/j.jhsa.2012.04.027","article-title":"Titanium integration with bone, welding, and screw head destruction complicating hardware removal of the distal radius: report of 2 cases","volume":"37","author":"Van Nortwick","year":"2012","journal-title":"J Hand Surg."},{"issue":"3","key":"bib15-20240805","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.artd.2020.05.018","article-title":"Disassociation of a cold-welded bimodular titanium femoral stem by intraoperative ice cooling","volume":"6","author":"Frandsen","year":"2020","journal-title":"Arthroplast Today."},{"issue":"2","key":"bib16-20240805","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.arth.2016.07.020","article-title":"Clinical cold welding of the modular total hip arthroplasty prosthesis","volume":"32","author":"Whittaker","year":"2017","journal-title":"J Arthroplasty."},{"issue":"22","key":"bib17-20240805","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.2106\/JBJS.20.02231","article-title":"Complications of hardware removal","volume":"103","author":"Kellam","year":"2021","journal-title":"J Bone Joint Surg Am."},{"issue":"10","key":"bib18-20240805","doi-asserted-by":"crossref","first-page":"3272","DOI":"10.1007\/s11999-015-4262-5","article-title":"Mortality and revision surgery are increased in patients with Parkinson's disease and fractures of the femoral neck","volume":"473","author":"Karadsheh","year":"2015","journal-title":"Clin Orthop Relat Res."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.22.00530","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:42:13Z","timestamp":1787751733000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.22.00530"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":17,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.22.00530","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]}}}