{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:40:52Z","timestamp":1787755252195,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>Olecranon fractures treated with proximal ulna plate fixation and repairing the triceps with suture augmentation to the plate decrease the risk of \u201colecranon escape,\u201d but may lead to failure through triceps rupture. In this case report, a rare complication of triceps rupture occurred, and the patient underwent triceps repair.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>When fixing olecranon fractures, surgeons should minimize triceps dissection for hardware placement. If subjected to significant force, a surgical insult to the tendon footprint for a better plate contact on the bone and the presence of suture augmentation may change the construct failure mechanism and result in triceps rupture as opposed to fracture redisplacement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.23.00179","type":"journal-article","created":{"date-parts":[[2023,8,17]],"date-time":"2023-08-17T15:26:34Z","timestamp":1692285994000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Triceps Rupture After Olecranon Fixation with Proximal Ulna Plate and Suture Augmentation"],"prefix":"10.2106","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4125-5862","authenticated-orcid":false,"given":"Sergio Eduardo","family":"Flores","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5507-3587","authenticated-orcid":false,"given":"Joseph Ryan","family":"Sheridan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8346-1464","authenticated-orcid":false,"given":"Eric Stanley","family":"Larson","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6624-759X","authenticated-orcid":false,"given":"Igor","family":"Immerman","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,7]]},"reference":[{"issue":"2","key":"bib1-20240805","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.ocl.2008.01.002","article-title":"Olecranon fractures","volume":"39","author":"Veillette","year":"2008","journal-title":"Orthop Clin North Am."},{"issue":"3","key":"bib2-20240805","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.jhsa.2012.12.036","article-title":"Olecranon fractures","volume":"38","author":"Baecher","year":"2013","journal-title":"J Hand Surg."},{"issue":"1","key":"bib4-20240805","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/BOT.0b013e318214e64c","article-title":"An off-loading triceps suture for augmentation of plate fixation in comminuted osteoporotic fractures of the olecranon","volume":"26","author":"Izzi","year":"2012","journal-title":"J Orthop Trauma."},{"issue":"2","key":"bib5-20240805","doi-asserted-by":"crossref","first-page":"e62","DOI":"10.1097\/BOT.0000000000002189","article-title":"Mitigation of triceps avulsion fracture after proximal ulna plate fixation","volume":"36","author":"Orbay","year":"2022","journal-title":"J Orthop Trauma."},{"issue":"10","key":"bib6-20240805","doi-asserted-by":"crossref","first-page":"2412","DOI":"10.1016\/j.jse.2021.03.138","article-title":"Complications and reoperations related to tension band wiring and plate osteosynthesis of olecranon fractures","volume":"30","author":"Rantalaiho","year":"2021","journal-title":"J Shoulder Elbow Surg."},{"issue":"5","key":"bib7-20240805","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1016\/j.jseint.2021.04.014","article-title":"Predicting secondary surgery after operative fixation of olecranon fractures: a model using data from 800 patients","volume":"5","author":"Midtgaard","year":"2021","journal-title":"JSES Int."},{"issue":"11","key":"bib8-20240805","doi-asserted-by":"crossref","first-page":"2052","DOI":"10.1016\/j.jse.2018.05.025","article-title":"Distal triceps transosseous cruciate versus suture anchor repair using equal constructs: a biomechanical comparison","volume":"27","author":"Carpenter","year":"2018","journal-title":"J Shoulder Elbow Surg."},{"issue":"1","key":"bib9-20240805","doi-asserted-by":"crossref","first-page":"31","DOI":"10.5435\/00124635-201001000-00005","article-title":"Distal triceps rupture","volume":"18","author":"Yeh","year":"2010","journal-title":"J Am Acad Orthop Surg."},{"issue":"1","key":"bib10-20240805","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jse.2021.06.019","article-title":"The surgical management of distal triceps tendon ruptures: a systematic review","volume":"31","author":"Alnaji","year":"2022","journal-title":"J Shoulder Elbow Surg."},{"issue":"9","key":"bib11-20240805","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/BOT.0b013e318239273c","article-title":"Biomechanical evaluation of suture-augmented locking plate fixation for proximal third fractures of the olecranon","volume":"26","author":"Wild","year":"2012","journal-title":"J Orthop Trauma."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.23.00179","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:40:10Z","timestamp":1787751610000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.23.00179"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":10,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.23.00179","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]}}}