{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:43:03Z","timestamp":1787755383631,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>We present the case of a 46-year-old patient with asymmetric deformity in the posterior tibial slope after previous high tibial osteotomy surgeries with the presence of a medial osteotomy plate. A customized cutting guide was designed to fit on the plate to perform a single surgery and avoid possible soft-tissue complications after multiple surgeries.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The presence of a previous internal fixation device may affect the manufacture of 3-dimensional cutting guides. However, in this case, the previously placed osteosynthesis plate was used as an aid for creating the guide.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.23.00520","type":"journal-article","created":{"date-parts":[[2024,2,2]],"date-time":"2024-02-02T14:03:40Z","timestamp":1706882620000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Is Previously Implanted Osteosynthesis Material an Obstacle for the Use of Customized Guides?"],"prefix":"10.2106","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2964-4913","authenticated-orcid":false,"given":"Carlos","family":"Jim\u00e9nez-Garrido","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery and Traumatology, QuironSalud Hospital M\u00e1laga, M\u00e1laga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raphael P.","family":"Idiart","sequence":"additional","affiliation":[{"name":"Vithas Xanit International Hospital, Benalm\u00e1dena, M\u00e1laga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Meschian-Coretti","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery and Traumatology, QuironSalud Hospital M\u00e1laga, M\u00e1laga, Spain"},{"name":"Vithas Xanit International Hospital, Benalm\u00e1dena, M\u00e1laga, Spain"},{"name":"Biomedical Research Institute of M\u00e1laga (IBIMA), M\u00e1laga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elvira","family":"Monta\u00f1ez-Heredia","sequence":"additional","affiliation":[{"name":"Vithas Xanit International Hospital, Benalm\u00e1dena, M\u00e1laga, Spain"},{"name":"Biomedical Research Institute of M\u00e1laga (IBIMA), M\u00e1laga, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1]]},"reference":[{"key":"bib1-20240805","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.jot.2022.03.001","article-title":"Clinical applications and prospects of 3D printing guide templates in orthopaedics","volume":"34","author":"Meng","year":"2022","journal-title":"J Orthop Translat."},{"issue":"1S","key":"bib2-20240805","doi-asserted-by":"crossref","first-page":"103154","DOI":"10.1016\/j.otsr.2021.103154","article-title":"Patient-specific guides in orthopedic surgery","volume":"108","author":"Gauci","year":"2022","journal-title":"Orthop Traumatol Surg Res."},{"issue":"4","key":"bib3-20240805","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1111\/aor.13358","article-title":"A new template and teleoperation system for human-guided spine surgery","volume":"43","author":"Azimifar","year":"2019","journal-title":"Artif Organs."},{"issue":"5","key":"bib4-20240805","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1007\/s00590-021-03043-8","article-title":"Patient-specific high tibial osteotomy for varus malalignment: 3D-printed plating technique and review of the literature","volume":"32","author":"Jeong","year":"2022","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"2","key":"bib5-20240805","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.otsr.2016.11.020","article-title":"Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study","volume":"103","author":"Munier","year":"2017","journal-title":"Orthop Traumatol Surg Res."},{"issue":"8","key":"bib6-20240805","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1055\/s-0036-1572412","article-title":"3D surgical printing cutting guides for open-wedge high tibial osteotomy: do it yourself","volume":"29","author":"P\u00e9rez-Ma\u00f1anes","year":"2016","journal-title":"J Knee Surg."},{"issue":"1","key":"bib7-20240805","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1186\/s12938-016-0236-4","article-title":"3D-printing techniques in a medical setting: a systematic literature review","volume":"15","author":"Tack","year":"2016","journal-title":"Biomed Eng Online."},{"issue":"12","key":"bib8-20240805","first-page":"CD004019","article-title":"Osteotomy for treating knee osteoarthritis","volume":"2014","author":"Brouwer","year":"2014","journal-title":"Cochrane Database Syst Rev."},{"issue":"50","key":"bib9-20240805","doi-asserted-by":"crossref","first-page":"e23692","DOI":"10.1097\/MD.0000000000023692","article-title":"Metal artifacts reduction in computed tomography: a phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging","volume":"99","author":"Ishikawa","year":"2020","journal-title":"Medicine (Baltimore)."},{"issue":"1","key":"bib10-20240805","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1186\/s13018-022-03057-w","article-title":"A novel 3D-printed patient-specific instrument based on \u201cH-point\u201d for medial opening wedge high tibial osteotomy: a cadaver study","volume":"17","author":"Liu","year":"2022","journal-title":"J Orthop Surg Res."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.23.00520","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:42:12Z","timestamp":1787751732000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.23.00520"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.23.00520","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]}}}