{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:24:47Z","timestamp":1787754287178,"version":"build-2784847793"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Case:<\/jats:title>\n                    <jats:p>A 48-year-old woman sustained an L1 burst fracture (AO Spine A4, N0, M1) after a 4-meter fall. Imaging demonstrated &gt;50% vertebral height loss, posterior wall retropulsion, and regional kyphosis without neurologic deficit. She underwent posterior segment pedicle screw fixation (T12-L2) with vertebral body stenting, an intravertebral graft scaffold filled with morselized cadaveric cancellous allograft. She mobilized within 48 hours, remained asymptomatic at 12 months, and follow-up CT demonstrated maintained alignment and consolidation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This case highlights operative considerations when using intravertebral stents in a young adult trauma patient, using cancellous allograft with posterior fixation for immediate stability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.cc.25.00553","type":"journal-article","created":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T18:00:32Z","timestamp":1777053632000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Beyond Cement: A Case Report of Cadaveric Allograft and Vertebral Body Stenting for a Traumatic Thoracolumbar Burst Fracture"],"prefix":"10.2106","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-9484-6135","authenticated-orcid":false,"given":"Adriano Francesco","family":"Borace","sequence":"first","affiliation":[{"name":"Centro Hospitalar e Universit\u00e1rio de Coimbra, Coimbra, Portugal"},{"name":"Department of Trauma and Orthopedics, Hospital Regional Dr. Rafael Hern\u00e1ndez, Chiriqu\u00ed, Panam\u00e1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-1083-6329","authenticated-orcid":false,"given":"Tomas F.","family":"Vega","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Rush University Medical Center, Chicago, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9350-0586","authenticated-orcid":false,"given":"Carla","family":"Castro","sequence":"additional","affiliation":[{"name":"Centro Hospitalar e Universit\u00e1rio de Coimbra, Coimbra, Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,4]]},"reference":[{"issue":"3","key":"bib1-20260424","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1007\/s00586-023-07537-3","article-title":"Anterior thoracolumbar column reconstruction with the vertebral body stent\u2014safety and efficacy","volume":"32","author":"Oswald","year":"2023","journal-title":"Eur Spine J."},{"issue":"11","key":"bib2-20260424","first-page":"1965","article-title":"Armed kyphoplasty: an indirect central canal decompression technique in burst fractures","volume":"40","author":"Venier","year":"2019","journal-title":"AJNR Am J Neuroradiol."},{"key":"bib3-20260424","doi-asserted-by":"crossref","first-page":"1142679","DOI":"10.3389\/fsurg.2023.1142679","article-title":"Internal replacement of a vertebral body in pseudarthrosis\u2014Armed kyphoplasty with bone graft-filled stents: case report","volume":"10","author":"Moura","year":"2023","journal-title":"Front Surg."},{"issue":"1","key":"bib4-20260424","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1136\/neurintsurg-2021-018628","article-title":"Treatment of A3.2 and A2 traumatic thoracolumbar spine compression fractures using vertebral body stenting: a 63- patient series","volume":"15","author":"Salle","year":"2023","journal-title":"J NeuroInterventional Surg."},{"issue":"19","key":"bib5-20260424","doi-asserted-by":"crossref","first-page":"E1147","DOI":"10.1097\/BRS.0000000000000470","article-title":"Cement augmentation in a thoracolumbar fracture model: reduction and stability after balloon kyphoplasty versus vertebral body stenting","volume":"39","author":"Disch","year":"2014","journal-title":"Spine."},{"issue":"11","key":"bib6-20260424","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1007\/s00270-019-02265-y","article-title":"Efficacy of the vertebral body stenting system for the restoration of vertebral height in acute traumatic compression fractures in a non-osteoporotic population","volume":"42","author":"Garnon","year":"2019","journal-title":"Cardiovasc Intervent Radiol."},{"issue":"6","key":"bib7-20260424","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1136\/bjsports-2016-096677","article-title":"AO surgery reference: a comprehensive guide for management of fractures","volume":"51","author":"Nambiar","year":"2017","journal-title":"Br J Sports Med."},{"issue":"11","key":"bib8-20260424","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1097\/BRS.0b013e3181714a84","article-title":"Calcium-phosphate and polymethylmethacrylate cement in long-term outcome after kyphoplasty of painful osteoporotic vertebral fractures","volume":"33","author":"Grafe","year":"2008","journal-title":"Spine."},{"issue":"1 Suppl","key":"bib9-20260424","doi-asserted-by":"crossref","first-page":"S169","DOI":"10.1016\/j.otsr.2013.11.005","article-title":"Kyphopasty and vertebroplasty","volume":"100","author":"Teyss\u00e9dou","year":"2014","journal-title":"Orthopaedics Traumatol Surg Res."},{"key":"bib10-20260424","doi-asserted-by":"crossref","first-page":"843","DOI":"10.2147\/CIA.S308667","article-title":"Stentoplasty with resorbable calcium salt bone VoidFillers for the treatment of vertebral compression fracture: evaluation after 3 years","volume":"16","author":"Chen","year":"2021","journal-title":"Clin Interventions Aging."},{"issue":"1","key":"bib11-20260424","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1186\/s13018-025-05857-2","article-title":"Bone void filler materials for augmentationin comminuted fractures: a comprehensive review","volume":"20","author":"Mohammadi","year":"2025","journal-title":"J Orthop Surg Res."},{"key":"bib18-20260424","article-title":"Percutaneous vertebroplasty and percutaneous balloon kyphoplasty for treating osteoporotic vertebral compression fractures","year":"2013","journal-title":"NICE Tech Appraisal Guidance TA279."},{"issue":"3","key":"bib19-20260424","doi-asserted-by":"crossref","first-page":"183","DOI":"10.5435\/00124635-201103000-00008","article-title":"AAOS clinical practice guideline: the treatment of symptomatic osteoporotic spinal compression fractures","volume":"19","author":"McGuire","year":"2011","journal-title":"J Am Acad Orthop Surg."},{"issue":"6","key":"bib14-20260424","doi-asserted-by":"crossref","first-page":"769","DOI":"10.31616\/asj.2020.0466","article-title":"Analysis of fracture patterns and characteristics in sacral insufficiency fracture: do sacral fractures occur in patients who had previous Lumbosacral fusion insufficiency fractures or stress fractures?","volume":"15","author":"Seo","year":"2021","journal-title":"Asian Spine J."},{"issue":"23","key":"bib15-20260424","doi-asserted-by":"crossref","first-page":"2028","DOI":"10.1097\/BRS.0b013e3182a8a381","article-title":"AOSpine thoracolumbar spine injury classification system: fracture description, neurological status, and key modifiers","volume":"38","author":"Vaccaro","year":"2013","journal-title":"Spine."},{"issue":"10","key":"bib16-20260424","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/j.injury.2011.04.006","article-title":"Early results after vertebral body stenting for fractures of the anterior column of the thoracolumbar spine","volume":"42","author":"Klezl","year":"2011","journal-title":"Injury."}],"container-title":["JBJS Case Connector"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.25.00553","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:25:15Z","timestamp":1787750715000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.CC.25.00553"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.cc.25.00553","relation":{},"ISSN":["2160-3251"],"issn-type":[{"value":"2160-3251","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}