{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:27:50Z","timestamp":1787754470730,"version":"build-2784847793"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"13","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,7,6]]},"DOI":"10.2106\/jbjs.j.00325","type":"journal-article","created":{"date-parts":[[2011,7,22]],"date-time":"2011-07-22T11:24:15Z","timestamp":1311333855000},"page":"1197-1202","source":"Crossref","is-referenced-by-count":52,"title":["Total Knee Arthroplasty with Use of Computer-Assisted Navigation Compared with Conventional Guiding Systems in the Same Patient: Radiographic Results in Asian Patients"],"prefix":"10.2106","volume":"93","author":[{"given":"Tsan-Wen","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Hsiu","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo-Ti","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Wen-Wei Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Jan","family":"Weng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wun-Jer","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20210131","first-page":"13","article-title":"Total knee arthroplasty","volume":"192","year":"1985","journal-title":"Clin Orthop Relat Res."},{"key":"bib2-20210131","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1054\/arth.2001.23569","article-title":"The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties","volume":"16","year":"2001","journal-title":"J Arthroplasty."},{"key":"bib3-20210131","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/S0883-5403(88)80054-8","article-title":"Radiographic assessment of knee alignment after total knee arthroplasty","volume":"3","year":"1988","journal-title":"J Arthroplasty."},{"key":"bib4-20210131","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1097\/01.blo.0000093029.56370.0f","article-title":"How accurate is current TKR instrumentation?","volume":"416","year":"2003","journal-title":"Clin Orthop Relat Res."},{"key":"bib5-20210131","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/01.blo.0000136835.40566.d9","article-title":"Navigation improves accuracy of rotational alignment in total knee arthroplasty","volume":"426","year":"2004","journal-title":"Clin Orthop Relat Res."},{"key":"bib6-20210131","first-page":"2","article-title":"Principles of total knee arthroplasty","volume":"2","year":"1991","journal-title":"Semin Arthroplasty."},{"key":"bib7-20210131","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.arth.2008.03.006","article-title":"Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty","volume":"24","year":"2009","journal-title":"J Arthroplasty."},{"key":"bib8-20210131","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.blo.0000229363.50361.25","article-title":"When computer-assisted knee replacement is the best alternative","volume":"452","year":"2006","journal-title":"Clin Orthop Relat Res."},{"issue":"7 Suppl 3","key":"bib9-20210131","first-page":"132","article-title":"Computer assisted navigation in total knee arthroplasty: comparison with conventional methods","volume":"20","year":"2005","journal-title":"J Arthroplasty."},{"key":"bib10-20210131","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.arth.2004.09.047","article-title":"Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation","volume":"20","year":"2005","journal-title":"J Arthroplasty."},{"key":"bib11-20210131","first-page":"152","article-title":"Computer-assisted navigation increases precision of component placement in total knee arthroplasty","volume":"433","year":"2005","journal-title":"Clin Orthop Relat Res."},{"key":"bib12-20210131","first-page":"372","article-title":"Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial","volume":"86","year":"2004","journal-title":"J Bone Joint Surg Br."},{"issue":"7 Suppl 3","key":"bib13-20210131","first-page":"123","article-title":"Computer assisted navigation in total knee arthroplasty: improved coronal alignment","volume":"20","year":"2005","journal-title":"J Arthroplasty."},{"key":"bib14-20210131","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.arth.2005.02.002","article-title":"Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses","volume":"20","year":"2005","journal-title":"J Arthroplasty."},{"key":"bib15-20210131","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/j.arth.2007.08.001","article-title":"Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery","volume":"22","year":"2007","journal-title":"J Arthroplasty."},{"key":"bib16-20210131","doi-asserted-by":"crossref","first-page":"765","DOI":"10.2106\/JBJS.G.00293","article-title":"Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty","volume":"90","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"bib17-20210131","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.arth.2008.02.018","article-title":"Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty","volume":"24","year":"2009","journal-title":"J Arthroplasty."},{"key":"bib18-20210131","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1177\/230949900901700209","article-title":"Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study","volume":"17","year":"2009","journal-title":"J Orthop Surg (Hong Kong)."},{"key":"bib19-20210131","first-page":"1025","article-title":"The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system","volume":"90","year":"2008","journal-title":"J Bone Joint Surg Br."},{"key":"bib20-20210131","first-page":"471","article-title":"Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study","volume":"89","year":"2007","journal-title":"J Bone Joint Surg Br."},{"key":"bib21-20210131","doi-asserted-by":"crossref","first-page":"236","DOI":"10.2106\/JBJS.F.00386","article-title":"A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation","volume":"89","year":"2007","journal-title":"J Bone Joint Surg Am."},{"key":"bib22-20210131","doi-asserted-by":"crossref","first-page":"14","DOI":"10.2106\/JBJS.G.01700","article-title":"Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty","volume":"91","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"bib23-20210131","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1016\/j.arth.2007.04.030","article-title":"Comparison of limb and component alignment using computer-assisted navigation versus image intensifier-guided conventional total knee arthroplasty: a prospective, randomized, single-surgeon study of 467 knees","volume":"22","year":"2007","journal-title":"J Arthroplasty."},{"key":"bib24-20210131","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1177\/230949900701500108","article-title":"Coronal bowing of the femur and tibia in Chinese: its incidence and effects on total knee arthroplasty planning","volume":"15","year":"2007","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"bib25-20210131","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1016\/j.arth.2009.05.005","article-title":"Computer-assisted total knee arthroplasty for arthritis with extra-articular deformity","volume":"24","year":"2009","journal-title":"J Arthroplasty."},{"key":"bib26-20210131","first-page":"215","article-title":"Normal axial alignment of the lower extremity and load-bearing distribution at the knee","volume":"255","year":"1990","journal-title":"Clin Orthop Relat Res."},{"key":"bib27-20210131","first-page":"9","article-title":"The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system","volume":"248","year":"1989","journal-title":"Clin Orthop Relat Res."},{"key":"bib28-20210131","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1097\/01.blo.0000218738.69247.d8","article-title":"Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties","volume":"449","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"bib29-20210131","first-page":"178","article-title":"Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations","volume":"173","year":"1983","journal-title":"Clin Orthop Relat Res."},{"key":"bib30-20210131","doi-asserted-by":"crossref","first-page":"160","DOI":"10.3109\/17453678408992329","article-title":"Total condylar knee arthroplasty. Prosthetic component positioning and radiolucent lines","volume":"55","year":"1984","journal-title":"Acta Orthop Scand."},{"key":"bib31-20210131","first-page":"153","article-title":"Postoperative alignment of total knee replacement. Its effect on survival","volume":"299","year":"1994","journal-title":"Clin Orthop Relat Res."},{"key":"bib32-20210131","first-page":"709","article-title":"Coronal alignment after total knee replacement","volume":"73","year":"1991","journal-title":"J Bone Joint Surg Br."},{"key":"bib33-20210131","first-page":"23","article-title":"Total joint arthroplasty of the knee","volume":"192","year":"1985","journal-title":"Clin Orthop Relat Res."},{"key":"bib34-20210131","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/01.blo.0000186561.70566.95","article-title":"Computer navigation versus standard instrumentation for TKA: a single-surgeon experience","volume":"440","year":"2005","journal-title":"Clin Orthop Relat Res."},{"key":"bib35-20210131","first-page":"830","article-title":"Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study","volume":"85","year":"2003","journal-title":"J Bone Joint Surg Br."},{"key":"bib36-20210131","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.arth.2005.02.002","article-title":"Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses","volume":"20","year":"2005","journal-title":"J Arthroplasty."},{"key":"bib37-20210131","doi-asserted-by":"crossref","first-page":"62","DOI":"10.3928\/0147-7447-19840101-09","article-title":"Alignment of total knee arthroplasty components","volume":"7","year":"1984","journal-title":"Orthopedics."},{"key":"bib38-20210131","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1097\/01.blo.0000238823.78895.dc","article-title":"Computer-assisted navigation in TKA: where we are and where we are going","volume":"452","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"bib39-20210131","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1054\/arth.2001.20908","article-title":"Radiologic analysis of the tibial intramedullary canal in Chinese varus knees: implications in total knee arthroplasty","volume":"16","year":"2001","journal-title":"J Arthroplasty."},{"key":"bib40-20210131","doi-asserted-by":"crossref","first-page":"342","DOI":"10.2106\/00004623-200003000-00005","article-title":"Simultaneous femoral osteotomy and total knee arthroplasty for treatment of osteoarthritis associated with severe extra-articular deformity","volume":"82","year":"2000","journal-title":"J Bone Joint Surg Am."},{"key":"bib41-20210131","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.2106\/00004623-200210000-00005","article-title":"Total knee arthroplasty for arthritis of the knee with extra-articular deformity","volume":"84","year":"2002","journal-title":"J Bone Joint Surg Am."},{"key":"bib42-20210131","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.orthres.2004.06.013","article-title":"Sagittal bowing of the distal femur in Chinese patients who require total knee arthroplasty","volume":"23","year":"2005","journal-title":"J Orthop Res."},{"key":"bib43-20210131","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1016\/j.arth.2008.05.025","article-title":"A comparison of coronal plane axial femoral relationships in Asian patients with varus osteoarthritic knees and healthy knees","volume":"24","year":"2009","journal-title":"J Arthroplasty."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00004623-201107060-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:27:59Z","timestamp":1787750879000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00004623-201107060-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7,6]]},"references-count":43,"journal-issue":{"issue":"13","published-print":{"date-parts":[[2011]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.j.00325","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,7,6]]}}}