{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:19:30Z","timestamp":1787753970895,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"17","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,9,5]]},"DOI":"10.2106\/jbjs.j.01673","type":"journal-article","created":{"date-parts":[[2012,11,15]],"date-time":"2012-11-15T15:56:59Z","timestamp":1352995019000},"page":"1597-1604","source":"Crossref","is-referenced-by-count":23,"title":["Mechanical Comparison of Novel Bioabsorbable Plates with Titanium Plates and Small-Series Clinical Comparisons for Metacarpal Fractures"],"prefix":"10.2106","volume":"94","author":[{"given":"Akinori","family":"Sakai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihisa","family":"Oshige","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukichi","family":"Zenke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunitaka","family":"Menuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teppei","family":"Murai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshitaka","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20210131","doi-asserted-by":"crossref","first-page":"148","DOI":"10.2106\/00004623-199173010-00022","article-title":"Absorbable implants for the fixation of fractures","volume":"73","year":"1991","journal-title":"J Bone Joint Surg Am."},{"key":"bib2-20210131","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.2106\/00004623-199072070-00009","article-title":"Refracture after removal of a condylar plate from the distal third of the femur","volume":"72","year":"1990","journal-title":"J Bone Joint Surg Am."},{"key":"bib3-20210131","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/01.blo.0000205884.81328.cc","article-title":"Bioabsorbable implants in the treatment of hand fractures: an update","volume":"445","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"bib4-20210131","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.2106\/00004623-199274070-00008","article-title":"Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies","volume":"74","year":"1992","journal-title":"J Bone Joint Surg Am."},{"key":"bib5-20210131","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/00000637-200208000-00015","article-title":"Biomechanical failure of metacarpal fracture resorbable plate fixation","volume":"49","year":"2002","journal-title":"Ann Plast Surg."},{"key":"bib6-20210131","doi-asserted-by":"crossref","first-page":"3197","DOI":"10.1016\/S0142-9612(01)00072-2","article-title":"Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly L-lactide (PLLA). Part II: practical properties of miniscrews and miniplates","volume":"22","year":"2001","journal-title":"Biomaterials."},{"key":"bib7-20210131","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.jhsa.2004.01.013","article-title":"Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports","volume":"29","year":"2004","journal-title":"J Hand Surg Am."},{"key":"bib8-20210131","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.jhsa.2007.02.005","article-title":"Clinical results of absorbable plates for displaced metacarpal fractures","volume":"32","year":"2007","journal-title":"J Hand Surg Am."},{"key":"bib9-20210131","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0142-9612(98)00241-5","article-title":"Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): Part I. Basic characteristics","volume":"20","year":"1999","journal-title":"Biomaterials."},{"key":"bib10-20210131","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1002\/(SICI)1097-4636(19991205)47:3<412::AID-JBM17>3.0.CO;2-B","article-title":"Bonding behavior of ultrahigh strength unsintered hydroxyapatite particles\/poly(L-lactide) composites to surface of tibial cortex in rabbits","volume":"47","year":"1999","journal-title":"J Biomed Mater Res."},{"key":"bib11-20210131","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1002\/(SICI)1097-4636(20000605)50:3<410::AID-JBM16>3.0.CO;2-Y","article-title":"Histomorphometric study on high-strength hydroxyapatite\/poly(L-lactide) composite rods for internal fixation of bone fractures","volume":"50","year":"2000","journal-title":"J Biomed Mater Res."},{"key":"bib12-20210131","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/00003086-200010000-00030","article-title":"Bone bonding ability of a new biodegradable composite for internal fixation of bone fractures","volume":"379","year":"2000","journal-title":"Clin Orthop Relat Res."},{"key":"bib13-20210131","doi-asserted-by":"crossref","first-page":"5542","DOI":"10.1016\/j.biomaterials.2005.02.016","article-title":"The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles\/poly l-lactide (F-u-HA\/PLLA)","volume":"26","year":"2005","journal-title":"Biomaterials."},{"key":"bib14-20210131","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1016\/j.bone.2010.08.012","article-title":"Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone","volume":"47","year":"2010","journal-title":"Bone."},{"key":"bib15-20210131","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.2106\/00004623-197456050-00012","article-title":"Review article. The mechanical properties of cortical bone","volume":"56","year":"1974","journal-title":"J Bone Joint Surg Am."},{"key":"bib16-20210131","first-page":"327","article-title":"Reinforcement of acrylic resins for provisional fixed restorations. Part I: mechanical properties","volume":"7","year":"1997","journal-title":"Biomed Mater Eng."},{"key":"bib17-20210131","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/01.blo.0000063789.32430.c6","article-title":"Bioabsorbable miniplating versus metallic fixation for metacarpal fractures","volume":"410","year":"2003","journal-title":"Clin Orthop Relat Res."},{"key":"bib18-20210131","first-page":"602","article-title":"Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]","volume":"29","year":"1996","journal-title":"The Upper Extremity Collaborative Group (UECG) Am J Ind Med."},{"key":"bib19-20210131","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/S0142-9612(99)00232-X","article-title":"Biodegradation behavior of ultra-high-strength hydroxyapatite\/poly (L-lactide) composite rods for internal fixation of bone fractures","volume":"21","year":"2000","journal-title":"Biomaterials."},{"key":"bib20-20210131","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1053\/jhsu.2001.24145","article-title":"Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation","volume":"26","year":"2001","journal-title":"J Hand Surg Am."},{"key":"bib21-20210131","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/j.biomaterials.2005.09.003","article-title":"A 5-7 year in vivo study of high-strength hydroxyapatite\/poly(L-lactide) composite rods for the internal fixation of bone fractures","volume":"27","year":"2006","journal-title":"Biomaterials."}],"container-title":["Journal of Bone and Joint Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00004623-201209050-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:21:38Z","timestamp":1787750498000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00004623-201209050-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,9,5]]},"references-count":21,"journal-issue":{"issue":"17","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.j.01673","relation":{},"ISSN":["0021-9355","1535-1386"],"issn-type":[{"value":"0021-9355","type":"print"},{"value":"1535-1386","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,9,5]]}}}