{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:39:36Z","timestamp":1787755176880,"version":"build-2784847793"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Change in vertebral position between preoperative imaging and the surgical procedure reduces the accuracy of image-guided spinal surgery, requiring repeated imaging and surgical field registration, a process that takes time and exposes patients to additional radiation. We developed a handheld, camera-based, deformable registration system (intraoperative stereovision, iSV) to register the surgical field automatically and compensate for spinal motion during surgery without further radiation exposure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We measured motion-induced errors in image-guided lumbar pedicle screw placement in 6 whole-pig cadavers using state-of-the-art commercial spine navigation (StealthStation; Medtronic) and iSV registration that compensates for intraoperative vertebral motion. We induced spinal motion by using preoperative computed tomography (pCT) of the lumbar spine performed in the supine position with accentuated lordosis and performing surgery with the animal in the prone position. StealthStation registration of pCT occurred using metallic fiducial markers implanted in each vertebra, and iSV data were acquired to perform a deformable registration between pCT and the surgical field. Sixty-eight pedicle screws were placed in 6 whole-pig cadavers using iSV and StealthStation registrations in random order of vertebral level, relying only on image guidance without invoking the surgeon\u2019s judgment. The position of each pedicle screw was assessed with post-procedure CT and confirmed via anatomical dissection. Registration errors were assessed on the basis of implanted fiducials.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The frequency and severity of pedicle screw perforation were lower for iSV registration compared with StealthStation (97% versus 68% with Grade 0 medial perforation for iSV and StealthStation, respectively). Severe perforation occurred only with StealthStation (18% versus 0% for iSV). The overall time required for iSV registration (computational efficiency) was \u223c10 to 15 minutes and was comparable with StealthStation registration (\u223c10 min). The mean target registration error was smaller for iSV relative to StealthStation (2.81 \u00b1 0.91 versus 8.37 \u00b1 1.76 mm).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Pedicle screw placement was more accurate with iSV registration compared with state-of-the-art commercial navigation based on preoperative CT when alignment of the spine changed during surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>The iSV system compensated for intervertebral motion, which obviated the need for repeated vertebral registration while providing efficient, accurate, radiation-free navigation during open spinal surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.oa.21.00129","type":"journal-article","created":{"date-parts":[[2022,3,21]],"date-time":"2022-03-21T14:02:16Z","timestamp":1647871336000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement"],"prefix":"10.2106","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0576-0087","authenticated-orcid":false,"given":"Xiaoyao","family":"Fan","sequence":"first","affiliation":[{"name":"Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sohail K.","family":"Mirza","sequence":"additional","affiliation":[{"name":"Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire"},{"name":"PEERClinic for Back Pain and Spine Surgery, Fairfax, Virginia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0444-742X","authenticated-orcid":false,"given":"Chen","family":"Li","sequence":"additional","affiliation":[{"name":"Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8752-7945","authenticated-orcid":false,"given":"Linton T.","family":"Evans","sequence":"additional","affiliation":[{"name":"Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire"},{"name":"Section of Neurosurgery, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2886-5781","authenticated-orcid":false,"given":"Songbai","family":"Ji","sequence":"additional","affiliation":[{"name":"Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire"},{"name":"Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6692-3196","authenticated-orcid":false,"given":"Keith D.","family":"Paulsen","sequence":"additional","affiliation":[{"name":"Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire"},{"name":"Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire"},{"name":"Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1]]},"reference":[{"issue":"3","key":"R1-20240801","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.ocl.2007.04.001","article-title":"Image guidance in spine surgery","volume":"38","author":"Holly","year":"2007","journal-title":"Orthop Clin North Am"},{"issue":"14","key":"R2-20240801","doi-asserted-by":"crossref","first-page":"R505","DOI":"10.1088\/0031-9155\/51\/14\/R01","article-title":"Image-guidance for surgical procedures","volume":"51","author":"Peters","year":"2006","journal-title":"Phys Med Biol"},{"issue":"1","key":"R3-20240801","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.wneu.2012.03.011","article-title":"Worldwide survey on the use of navigation in spine surgery","volume":"79","author":"H\u00e4rtl","year":"2013","journal-title":"World Neurosurg"},{"issue":"4","key":"R4-20240801","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/S1935-9810(08)70038-0","article-title":"Surgeons\u2019 perceptions of spinal navigation: analysis of key factors affecting the lack of adoption of spinal navigation technology","volume":"2","author":"Choo","year":"2008","journal-title":"SAS J"},{"issue":"15","key":"R5-20240801","doi-asserted-by":"crossref","first-page":"S54","DOI":"10.1097\/01.BRS.0000076899.78522.D9","article-title":"Intraoperative spinal navigation","volume":"28","author":"Holly","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"R6-20240801","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1097\/01.BRS.0000048461.51308.CD","article-title":"Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study","volume":"28","author":"Mirza","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"R7-20240801","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1007\/s00586-010-1683-4","article-title":"Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques","volume":"20","author":"Silbermann","year":"2011","journal-title":"Eur Spine J"},{"issue":"4","key":"R8-20240801","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/00007632-200102150-00018","article-title":"Initial experience with intraoperative magnetic resonance imaging in spine surgery","volume":"26","author":"Woodard","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"R9-20240801","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1148\/rg.276065205","article-title":"Lumbar spine fusion and stabilization: hardware, techniques, and imaging appearances","volume":"27","author":"Rutherford","year":"2007","journal-title":"Radiographics"},{"key":"R10-20240801","first-page":"9786","article-title":"Automatic geometric rectification for patient registration in image-guided spinal surgery","author":"Cai","year":"2016","journal-title":"Med Imag Image-Guid Proc Robot Interv Mod."},{"issue":"6","key":"R11-20240801","first-page":"943","article-title":"A level-wise spine registration framework to account for large pose changes","volume":"16","author":"Cai","year":"2021","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"4","key":"R12-20240801","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1093\/ons\/opaa057","article-title":"Hand-Held Stereovision System for Image Updating in Open Spine Surgery","volume":"19","author":"Fan","year":"2020","journal-title":"Oper Neurosurg (Hagerstown)."},{"issue":"11","key":"R13-20240801","first-page":"e6158","article-title":"Using Porcine Cadavers as an Alternative to Human Cadavers for Teaching Minimally Invasive Spinal Fusion: Proof of Concept and Anatomical Comparison","volume":"11","author":"Abbasi","year":"2019","journal-title":"Cureus"},{"issue":"4","key":"R14-20240801","first-page":"810","article-title":"Fiducial point placement and the accuracy of point-based, rigid body registration","volume":"48","author":"West","year":"2001","journal-title":"Neurosurgery"},{"key":"R15-20240801","first-page":"10951","article-title":"Calibration of a hand-held stereovision system for image-guided spinal surgery","author":"Fan","year":"2019","journal-title":"Med Imag Visual Image-Guid Proc Mod."},{"key":"R16-20240801","first-page":"7261","article-title":"Fiducial registration error and target registration error are uncorrelated","author":"Fitzpatrick","year":"2009","journal-title":"Med Imag Visual Image-Guid Proc Mod."},{"issue":"1","key":"R17-20240801","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine (Phila Pa 1976)"},{"issue":"8","key":"R18-20240801","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1007\/s00586-006-0245-2","article-title":"Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine","volume":"16","author":"Lien","year":"2007","journal-title":"Eur Spine J"},{"issue":"3","key":"R19-20240801","doi-asserted-by":"crossref","first-page":"298","DOI":"10.4103\/jnrp.jnrp_508_17","article-title":"Comparison of Four Radiographic Angular Measures of Lumbar Lordosis","volume":"9","author":"Okpala","year":"2018","journal-title":"J Neurosci Rural Pract"},{"issue":"3","key":"R20-20240801","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/2010.1.FOCUS09275","article-title":"Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery","volume":"28","author":"Tormenti","year":"2010","journal-title":"Neurosurg Focus"},{"issue":"4","key":"R21-20240801","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s00264-007-0358-1","article-title":"Pedicle screw insertion: computed tomography versus fluoroscopic image guidance","volume":"32","author":"Fu","year":"2008","journal-title":"Int Orthop"},{"issue":"4","key":"R22-20240801","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1097\/00006123-200010000-00017","article-title":"Computer-assisted fluoroscopic targeting system for pedicle screw insertion","volume":"47","author":"Choi","year":"2000","journal-title":"Neurosurgery"},{"issue":"4","key":"R23-20240801","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1007\/s00264-009-0792-3","article-title":"Image-guided pedicle screw insertion accuracy: a meta-analysis","volume":"33","author":"Tian","year":"2009","journal-title":"Int Orthop"},{"issue":"5","key":"R24-20240801","first-page":"69","article-title":"The evolution of image-guided lumbosacral spine surgery","volume":"3","author":"Bourgeois","year":"2015","journal-title":"Ann Transl Med"},{"issue":"3","key":"R25-20240801","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.spinee.2004.10.048","article-title":"Accuracy of single-time, multilevel registration in image-guided spinal surgery","volume":"5","author":"Papadopoulos","year":"2005","journal-title":"Spine J"},{"key":"R27-20240801","first-page":"11315","article-title":"Stereovision-updated image guidance in multi-level open spine surgery: short vs. long exposure","author":"Fan","year":"2020","journal-title":"Med Imag Imag-Guid Proc Robot Intervent Mod."}],"container-title":["JBJS Open Access"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.OA.21.00129","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:38:45Z","timestamp":1787751525000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.OA.21.00129"}},"subtitle":["A Cadaveric Swine Study"],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.oa.21.00129","relation":{},"ISSN":["2472-7245"],"issn-type":[{"value":"2472-7245","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}