{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:46:53Z","timestamp":1787755613803,"version":"build-2784847793"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The use of porous metal acetabular components combined with augments is a potential approach for revision hip arthroplasty in cases of severe bone defects. However, the strength of the augment-acetabular cup interface has not been studied previously. This study evaluated the interfacial strength between acetabular cups and augments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The strength of the interface between the augment, bone cement, and the acetabular cup was tested using lever-out test. The effects of contact area and type of bone cement on the interface strength were investigated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The interfaces exhibited excellent stability. With the same cup-augment combination and different bone cements with different properties, no statistical differences were observed in main mechanical indicators (p &gt; 0.05); however, when the same bone cement was used with different cup-augment combinations, the maximum moment and yield moment decreased significantly with a decrease in the contact area (p &lt; 0.05). The interface stiffness exhibited a decreasing trend, although the difference was not statistically significant. Failure always occurred on the cement-acetabular cup side.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The interface between the acetabular cup and augment is stable and primarily influenced by the size of the contact area, not the type and mechanical properties of bone cement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>This study provides a theoretical basis for the use of augments during revision surgery. The factors affecting the strength were explored. This could promote the improvement of prostheses and guide the design of a new generation of prostheses.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.oa.24.00245","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T14:00:37Z","timestamp":1749218437000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Interfacial Strength Between Porous Metal Acetabular Components and Augments"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8786-719X","authenticated-orcid":false,"given":"Chenao","family":"Xiong","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zehao","family":"Jing","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4368-2913","authenticated-orcid":false,"given":"Renhua","family":"Ni","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-5104-4070","authenticated-orcid":false,"given":"Yiyuan","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dexuan","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-8744-4545","authenticated-orcid":false,"given":"Xu","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1751-9286","authenticated-orcid":false,"given":"Youhao","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5755-4838","authenticated-orcid":false,"given":"Hong","family":"Cai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Engineering Research Center of Bone and Joint Precision Medicine, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4]]},"reference":[{"issue":"9597","key":"R1-20250606","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","article-title":"The operation of the century: total hip replacement","volume":"370","author":"Learmonth","year":"2007","journal-title":"Lancet"},{"issue":"4","key":"R2-20250606","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/00004623-200704000-00012","article-title":"Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030","volume":"89","author":"Kurtz","year":"2007","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"R3-20250606","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1007\/s00264-007-0364-3","article-title":"Total hip arthroplasties: what are the reasons for revision?","volume":"32","author":"Ulrich","year":"2008","journal-title":"Int Orthop."},{"issue":"2","key":"R4-20250606","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.arth.2022.08.010","article-title":"Metal augments used in revision hip arthroplasty: a systematic review and single-arm meta-analysis","volume":"38","author":"Xiong","year":"2023","journal-title":"J Arthroplasty"},{"issue":"5","key":"R5-20250606","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/j.arth.2022.11.003","article-title":"Minimum 30-year results of bilaterally implanted cemented and cementless total hip arthroplasty in patients younger than 50 years","volume":"38","author":"Kim","year":"2023","journal-title":"J Arthroplasty"},{"issue":"1","key":"R6-20250606","doi-asserted-by":"crossref","first-page":"103","DOI":"10.52628\/88.1.13","article-title":"Early aseptic loosening of the tibial component at the cement-implant interface in total knee arthroplasty: a narrative overview of potentially associated factors","volume":"88","author":"van Otten","year":"2022","journal-title":"Acta Orthopaedica Belgica"},{"issue":"7","key":"R7-20250606","doi-asserted-by":"crossref","first-page":"2497","DOI":"10.1016\/j.arth.2021.02.029","article-title":"Where is the \u201cweak link\u201d of fixation in contemporary cemented total knee replacements?","volume":"36","author":"Martin","year":"2021","journal-title":"J Arthroplasty"},{"issue":"5","key":"R8-20250606","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1080\/10255840902718626","article-title":"Stresses in cement mantles of hip replacements: effect of femoral implant sizes, body mass index and bone quality","volume":"12","author":"Lamvohee","year":"2009","journal-title":"Comput Methods Biomech Biomed Eng."},{"issue":"2","key":"R9-20250606","doi-asserted-by":"crossref","first-page":"021019","DOI":"10.1115\/1.2904466","article-title":"In vitro fatigue failure of cemented acetabular replacements: a hip simulator study","volume":"130","author":"Zant","year":"2008","journal-title":"J Biomech Eng."},{"issue":"15","key":"R10-20250606","doi-asserted-by":"crossref","first-page":"2882","DOI":"10.1016\/j.jbiomech.2005.10.010","article-title":"In vitro fatigue behaviour of a cemented acetabular reconstruction","volume":"39","author":"Heaton-Adegbile","year":"2006","journal-title":"J Biomech."},{"issue":"8","key":"R11-20250606","doi-asserted-by":"crossref","first-page":"2936","DOI":"10.1016\/j.arth.2021.03.040","article-title":"Midterm outcomes after reconstruction of superolateral acetabular defects using flying buttress porous tantalum augments during revision total hip arthroplasty","volume":"36","author":"Cassar-Gheiti","year":"2021","journal-title":"J Arthroplasty"},{"issue":"6","key":"R12-20250606","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1016\/j.arth.2015.01.001","article-title":"Trabecular metal augments for the management of paprosky type III defects without pelvic discontinuity","volume":"30","author":"Grappiolo","year":"2015","journal-title":"J Arthroplasty"},{"issue":"4","key":"R13-20250606","doi-asserted-by":"crossref","first-page":"347","DOI":"10.3109\/17453674.2012.718518","article-title":"Use of porous trabecular metal augments with impaction bone grafting in management of acetabular bone loss","volume":"83","author":"Borland","year":"2012","journal-title":"Acta Orthopaedica"},{"issue":"3","key":"R14-20250606","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/0883-5403(92)90052-R","article-title":"Stability of press-fit acetabular cups","volume":"7","author":"Adler","year":"1992","journal-title":"J Arthroplasty"},{"issue":"3","key":"R15-20250606","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.arth.2009.03.003","article-title":"Mechanical stability of novel highly porous metal acetabular components in revision total hip arthroplasty","volume":"25","author":"Meneghini","year":"2010","journal-title":"J Arthroplasty"},{"issue":"7","key":"R16-20250606","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/j.arth.2009.06.025","article-title":"Does ischial screw fixation improve mechanical stability in revision total hip arthroplasty?","volume":"25","author":"Meneghini","year":"2010","journal-title":"J Arthroplasty"},{"key":"R17-20250606","first-page":"154","article-title":"A comparison of the disassociation strength of modular acetabular components","volume":"296","author":"Tradonsky","year":"1993","journal-title":"Clin Orthopaedics Relat Res."},{"issue":"6","key":"R18-20250606","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1054\/arth.2001.25501","article-title":"The strength of a cement acetabular locking mechanism","volume":"16","author":"Meldrum","year":"2001","journal-title":"J Arthroplasty"},{"issue":"6","key":"R19-20250606","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.2106\/00004623-200306000-00019","article-title":"A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell","volume":"85","author":"Haft","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R20-20250606","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.clinbiomech.2019.08.012","article-title":"Inferior extended fixation utilizing porous titanium augments improves primary anti-rotational stability of the acetabular component","volume":"70","author":"Tang","year":"2019","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"3","key":"R21-20250606","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1302\/0301-620X.77B3.7744942","article-title":"Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation?","volume":"77","author":"Won","year":"1995","journal-title":"J Bone Joint Surg Br."},{"issue":"11","key":"R22-20250606","doi-asserted-by":"crossref","first-page":"2966","DOI":"10.1002\/jor.24052","article-title":"Cement interface and bone stress in total hip arthroplasty: relationship to head size","volume":"36","author":"Alonso-Rasgado","year":"2018","journal-title":"J orthopaedic Res"},{"issue":"2","key":"R23-20250606","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/S0883-5403(98)90100-0","article-title":"An in vitro study of a new design of acetabular cement pressurizer","volume":"13","author":"Bernoski","year":"1998","journal-title":"J Arthroplasty"},{"issue":"3","key":"R24-20250606","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1016\/j.arth.2012.07.035","article-title":"High initial stability in porous titanium acetabular cups: a biomechanical study","volume":"28","author":"Small","year":"2013","journal-title":"J Arthroplasty"},{"issue":"2","key":"R25-20250606","first-page":"65","article-title":"Realistic loads for testing hip implants","volume":"20","author":"Bergmann","year":"2010","journal-title":"Biomed Mater Eng."}],"container-title":["JBJS Open Access"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.OA.24.00245","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:45:50Z","timestamp":1787751950000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.OA.24.00245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":25,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.oa.24.00245","relation":{},"ISSN":["2472-7245"],"issn-type":[{"value":"2472-7245","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}