{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:23:13Z","timestamp":1787750593094,"version":"build-2784847793"},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Cementless total knee arthroplasty (TKA) has gained renewed interest with advances in implant design, porous coatings, and surgical accuracy. However, early aseptic loosening continues to be reported, particularly in patients with reduced tibial bone mineral density (BMD). Cemented TKA also demonstrates loosening related to thin or insufficient cement mantles, especially in younger, high-body mass index, or highly active patients. Despite advances in available fixation methods, clear and reproducible criteria to guide fixation selection have yet to be established.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A narrative review was conducted to summarize recent evidence regarding fixation strategy in TKA with a focus on tibial BMD. A PubMed literature search identified studies published between 2016 and 2026 using terms related to fixation methods (cementless and cemented TKA), tibial bone density, loosening mechanisms (migration, subsidence, early failure), and cementing techniques (cement mantle thickness and cement penetration). The initial search yielded 289 articles, of which 84 studies relevant to bone density, fixation stability, implant design, and loosening mechanisms were included.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Large database studies consistently reported higher early aseptic loosening rates in cementless TKA, particularly in patients with low tibial BMD. Radiostereometric analyses demonstrated increased migration of cementless tibial components in low-density bone. In cemented TKA, inadequate cement penetration and thin or nonuniform cement mantles were strongly associated with tibial loosening. Recent computed tomography\u2013based techniques\u2014including hydroxyapatite-equivalent BMD and dual-energy computed tomography volumetric BMD\u2014show strong correlations with trabecular bone strength and provide practical thresholds for fixation selection.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      Based on the results of all the papers reviewed, tibial BMD values are important and do influence the loosening rate of tibial components. Those patients with tibial BMD values below 46.4 HA\/cm\n                      <jats:sup>3<\/jats:sup>\n                      support the use of cemented fixation, while those exceeding 78.4 HA\/cm\n                      <jats:sup>3<\/jats:sup>\n                      seem to be better candidates for cementless fixation due to limited cement penetration.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.oa.26.00087","type":"journal-article","created":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T18:01:35Z","timestamp":1782410495000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Reframing Fixation Strategy in Total Knee Arthroplasty With Tibial Bone Density as a Central Criterion"],"prefix":"10.2106","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4176-5531","authenticated-orcid":false,"given":"Yoshinori","family":"Mikashima","sequence":"first","affiliation":[{"name":"Oume Knee Surgery Center, Takagi Hospital, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1274-8406","authenticated-orcid":false,"given":"Ken","family":"Okazaki","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Tokyo Women\u2019s Medical University, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,4]]},"reference":[{"issue":"3","key":"R1-20260625","doi-asserted-by":"crossref","first-page":"e70356","DOI":"10.1002\/jeo2.70356","article-title":"Low frequency of radiolucent lines in 3D-printed porous-coated tibial cementless baseplate at 1-year follow-up","volume":"12","author":"Mikashima","year":"2025","journal-title":"J Exp Orthop"},{"issue":"7S1","key":"R2-20260625","doi-asserted-by":"crossref","first-page":"S250","DOI":"10.1016\/j.arth.2025.02.043","article-title":"10-year follow-up for a new three-dimensional printed cementless total knee arthroplasty","volume":"40","author":"Zappley","year":"2025","journal-title":"J Arthroplasty"},{"issue":"21","key":"R3-20260625","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.2106\/JBJS.23.00221","article-title":"Continued stabilization of a cementless 3D-Printed total knee arthroplasty: five-year results of a randomized controlled trial using radiostereometric analysis","volume":"105","author":"Van Der Lelij","year":"2023","journal-title":"J Bone Joint Surg"},{"issue":"2","key":"R4-20260625","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1007\/s11845-025-03888-6","article-title":"Improved performance of cementless total knee arthroplasty (TKA)across international registries: a comparative review","volume":"194","author":"de Grae","year":"2025","journal-title":"Ir J Med Sci"},{"issue":"1","key":"R5-20260625","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s00402-024-05670-2","article-title":"Cementless fixation in total knee arthroplasty: current evidence and future perspective","volume":"145","author":"Haslhofer","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"issue":"9S2","key":"R6-20260625","doi-asserted-by":"crossref","first-page":"S45","DOI":"10.1016\/j.arth.2024.02.078","article-title":"Cementless total knee arthroplasty: a resurgence\u2014who, when, where, and how?","volume":"39","author":"Mosher","year":"2024","journal-title":"J Arthroplasty"},{"key":"R7-20260625","doi-asserted-by":"crossref","first-page":"101122","DOI":"10.1016\/j.artd.2023.101122","article-title":"Cementless compared to cemented total knee arthroplasty is associated with more revisions within 1 year of index surgery","volume":"21","author":"Chiou","year":"2023","journal-title":"Arthroplast Today"},{"issue":"4","key":"R8-20260625","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1007\/s00590-024-03847-4","article-title":"Cemented is not superior to cementless total knee arthroplasty for complications: a propensity score matched analysis","volume":"34","author":"Monarrez","year":"2024","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"R10-20260625","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.jisako.2024.05.015","article-title":"Relationship between cement penetration and incidence of a radiolucent line around the tibia 2 years after total knee arthroplasty: a retrospective study","volume":"9","author":"Sasaki","year":"2024","journal-title":"J ISAKOS"},{"issue":"7","key":"R11-20260625","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1016\/j.arth.2024.12.023","article-title":"Aseptic tibial loosening is associated with thickness of the cement: a radiographic case\u2013control study","volume":"40","author":"Schaffler","year":"2025","journal-title":"J Arthroplasty"},{"issue":"4","key":"R12-20260625","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1302\/2633-1462.74.BJO-2025-0348.R2","article-title":"Cement mantle thickness in total knee arthroplasty more closely associated with tibial bone density than cement viscosity findings from a randomized controlled trial","volume":"7","author":"Mikashima","year":"2026","journal-title":"Bone Joint Open"},{"issue":"8","key":"R13-20260625","doi-asserted-by":"crossref","first-page":"e363","DOI":"10.5435\/JAAOS-D-20-00569","article-title":"Cementless fixation in primary total knee arthroplasty: historical perspective to contemporary application","volume":"29","author":"Kamath","year":"2021","journal-title":"J Am Acad Orthop Surg"},{"key":"R14-20260625","doi-asserted-by":"crossref","first-page":"100894","DOI":"10.1016\/j.jisako.2025.100894","article-title":"Preoperative computer tomography scans can accurately evaluate tibial bone mineral density for selecting bone fixation in total knee arthroplasty","volume":"12","author":"Mikashima","year":"2025","journal-title":"J ISAKOS"},{"issue":"7","key":"R15-20260625","first-page":"1305","article-title":"Volumetric bone mineral density assessed by dual-energy CT predicts bone strength suitability for cementless total knee arthroplasty","volume":"61","author":"Lee","year":"2025","journal-title":"Medicina (Lithuania)"},{"issue":"8","key":"R16-20260625","first-page":"1085","article-title":"Dual-energy CT-Based bone mineral density has practical value for osteoporosis screening around the knee","volume":"58","author":"Choi","year":"2022","journal-title":"Medicina (Lithuania)"},{"issue":"6","key":"R17-20260625","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1302\/2046-3758.66.BJR-2016-0113.R3","article-title":"Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data","volume":"6","author":"Stentz-Olesen","year":"2017","journal-title":"Bone Joint Res"},{"issue":"7 suppl 2","key":"R18-20260625","doi-asserted-by":"crossref","first-page":"S215","DOI":"10.1016\/j.arth.2023.02.058","article-title":"Cementless total knee arthroplasty is associated with early aseptic loosening in a large national database","volume":"38","author":"Forlenza","year":"2023","journal-title":"J Arthroplasty"},{"issue":"4","key":"R19-20260625","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1302\/0301-620X.107B4.BJJ-2024-0704.R1","article-title":"Early aseptic loosening and inferior patient-reported outcomes of a cementless tibial baseplate in a modern total knee arthroplasty designCite this article","volume":"107","author":"Andronic","year":"2025","journal-title":"Bone Joint J"},{"issue":"1","key":"R20-20260625","doi-asserted-by":"crossref","first-page":"10797","DOI":"10.1038\/s41598-021-90142-5","article-title":"The limit of tolerable micromotion for implant osseointegration: a systematic review","volume":"11","author":"Kohli","year":"2021","journal-title":"Sci Rep"},{"issue":"3","key":"R21-20260625","doi-asserted-by":"crossref","first-page":"e23:00032","DOI":"10.2106\/JBJS.OA.23.00032","article-title":"Tibial component undersizing is related to high degrees of implant migration following cementless total knee arthroplasty: a study of radiostereometric analysis data for 111 patients with 2-Year Follow-up","volume":"8","author":"Andersen","year":"2023","journal-title":"JBJS Open Access"},{"issue":"3","key":"R22-20260625","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1016\/j.arth.2024.09.023","article-title":"Early aseptic tibial loosening is a concern with a modern two-peg cementless total knee arthroplasty design","volume":"40","author":"Gibian","year":"2025","journal-title":"J Arthroplasty"},{"issue":"13","key":"R23-20260625","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.2106\/JBJS.18.01162","article-title":"Cemented versus cementless total knee arthroplasty of the same modern design: a prospective, randomized trial","volume":"101","author":"Nam","year":"2019","journal-title":"J Bone Joint Surg Am"},{"issue":"9","key":"R24-20260625","doi-asserted-by":"crossref","first-page":"3131","DOI":"10.1007\/s00167-022-07047-7","article-title":"Modern cementless posterior stabilized mobile-bearing total knee arthroplasty shows comparable clinical and radiographical results to its cemented predecessor at 1-year follow-up","volume":"30","author":"Mikashima","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"R25-20260625","doi-asserted-by":"crossref","first-page":"e12095","DOI":"10.1002\/jeo2.12095","article-title":"Comprehensive evaluation of risk factors for aseptic loosening in cemented total knee arthroplasty: a systematic review and meta-analysis","volume":"11","author":"Yao","year":"2024","journal-title":"J Exp Orthop"},{"issue":"1","key":"R26-20260625","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1186\/s12891-024-07913-0","article-title":"Does body mass index (BMI) significantly influence aseptic loosening in primary total knee arthroplasty? Insights from a long-term retrospective cohort study","volume":"25","author":"Ayati Firoozabadi","year":"2024","journal-title":"BMC Musculoskelet Disord"},{"key":"R27-20260625","doi-asserted-by":"crossref","first-page":"101621","DOI":"10.1016\/j.artd.2025.101621","article-title":"Revision rates for aseptic loosening in the Obese patient: a comparison between stemmed, uncemented, and unstemmed tibial total knee arthroplasty components","volume":"32","author":"van Duren","year":"2025","journal-title":"Arthroplast Today"},{"issue":"1","key":"R28-20260625","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/s00402-025-05880-2","article-title":"The vast majority of radiolucent lines disappeared at 3 years follow-up in modern cementless posterior stabilized mobile-bearing total knee arthroplasty","volume":"145","author":"Mikashima","year":"2025","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"R29-20260625","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1002\/jor.23459","article-title":"BMI-related microstructural changes in the tibial subchondral trabecular bone of patients with knee osteoarthritis","volume":"35","author":"Reina","year":"2017","journal-title":"J Orthop Res"},{"issue":"5","key":"R30-20260625","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1111\/os.70025","article-title":"Creating perforations in the sclerotic region of the proximal tibia during total knee arthroplasty to enhance prosthesis stability","volume":"17","author":"Sun","year":"2025","journal-title":"Orthop Surg"},{"issue":"3","key":"R31-20260625","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jjoisr.2025.06.001","article-title":"Proximal tibia bone mineral density correlates more closely with hip density in men with knee osteoarthritis","volume":"3","author":"Itou","year":"2025","journal-title":"J Joint Surg Res"},{"issue":"03","key":"R33-20260625","doi-asserted-by":"crossref","first-page":"172","DOI":"10.4236\/ojrad.2015.53021","article-title":"Evaluation of effective dose using the k-Factor of optimal scan range for CT examination","volume":"05","author":"Kobayashi","year":"2015","journal-title":"Open J Radiol"},{"issue":"4","key":"R35-20260625","doi-asserted-by":"crossref","first-page":"S64","DOI":"10.1016\/j.jcct.2024.05.150","article-title":"Comprehensive assessment of CT hounsfield unit variation within patients, scanners, and integrated measures","volume":"18","author":"Krishnan","year":"2024","journal-title":"J Cardiovasc Computed Tomography"},{"issue":"9","key":"R36-20260625","doi-asserted-by":"crossref","first-page":"ziae096","DOI":"10.1093\/jbmrpl\/ziae096","article-title":"Asynchronous calibration of a CT scanner for bone mineral density estimation: sources of error and correction","volume":"8","author":"Dudle","year":"2024","journal-title":"JBMR Plus"},{"issue":"7","key":"R37-20260625","doi-asserted-by":"crossref","first-page":"236","DOI":"10.3390\/jimaging11070236","article-title":"Bone mineral density (BMD) assessment using dual-energy CT with different base material pairs (BMPs)","volume":"11","author":"Piscone","year":"2025","journal-title":"J Imaging"},{"issue":"1","key":"R38-20260625","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1007\/s00402-025-06033-1","article-title":"Intraoperative evaluation of bone resection accuracy in total knee arthroplasty using an augmented reality-based navigation system","volume":"145","author":"Sato","year":"2025","journal-title":"Arch Orthop Trauma Surg"},{"issue":"15","key":"R39-20260625","doi-asserted-by":"crossref","first-page":"5205","DOI":"10.3390\/jcm14155205","article-title":"Accuracy of ROSA knee system in bone cuts orientation during total knee arthroplasty: an observational study","volume":"14","author":"Petrillo","year":"2025","journal-title":"J Clin Med"},{"issue":"11","key":"R40-20260625","doi-asserted-by":"crossref","first-page":"e0313391","DOI":"10.1371\/journal.pone.0313391","article-title":"Better accuracy of robotic-assisted total knee arthroplasty compared to conventional technique in patients with failed high tibial osteotomy","volume":"19","author":"Baek","year":"2024","journal-title":"PLoS One"},{"key":"R41-20260625","doi-asserted-by":"crossref","first-page":"103145","DOI":"10.1016\/j.jcot.2025.103145","article-title":"Retrospective analysis of early functional and radiological outcomes between robotic, navigated and conventional total knee arthroplasty: a single Surgeon's series","volume":"69","author":"Leong","year":"2025","journal-title":"J Clin Orthop Trauma"},{"issue":"1","key":"R42-20260625","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1186\/s12891-025-09102-z","article-title":"Use of robotics may facilitate earlier functional recovery and reduce overcorrection compared to conventional implantation techniques in total knee arthroplasty: a single-surgeon cohort study","volume":"26","author":"Ghossein","year":"2025","journal-title":"BMC Musculoskelet Disord"},{"key":"R43-20260625","first-page":"e1523","article-title":"Robotics in TKA: state of the art and future perspectives","volume":"3","author":"Montagna","year":"2025","journal-title":"Joints"},{"key":"R44-20260625","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1051\/sicotj\/2025048","article-title":"Prevalence of low bone mineral density in robotic-assisted TKA candidates: insights from quantitative CT analysis","volume":"11","author":"Garibaldi","year":"2025","journal-title":"SICOT J"},{"issue":"9","key":"R45-20260625","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3390\/biomimetics10090634","article-title":"Novel clinical applications of 3D-printed highly porous titanium for off-the-shelf cementless joint replacement prostheses","volume":"10","author":"Tigani","year":"2025","journal-title":"Biomimetics"}],"container-title":["JBJS Open Access"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.OA.26.00087","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:04:48Z","timestamp":1787749488000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.OA.26.00087"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":42,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.oa.26.00087","relation":{},"ISSN":["2472-7245"],"issn-type":[{"value":"2472-7245","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}