{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T15:49:48Z","timestamp":1793980188549,"version":"4.8.0"},"reference-count":57,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Use of computer-assisted navigation (CAN) and robotic-assisted (RA) surgery in total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) both necessitate the use of tracking pins rigidly fixed to the femur and tibia. Although periprosthetic fractures through tracking pin sites are rare, there is a paucity of literature on this potential complication. Therefore, the purpose of this study was to perform a systematic review of the current literature to assess the incidence and clinical outcomes of periprosthetic fractures through tracking pin sites following CAN and RA TKA and UKA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A systematic review was performed following PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines using the PubMed, MEDLINE, and Cochrane databases in April 2020. Studies were assessed for the presence of pin site fractures, fracture characteristics, and clinical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Seventeen clinical studies (5 case series, 1 cohort study, and 11 case reports) involving 29 pin-related fractures were included for review. The overall incidence ranged from 0.06% to 4.8%. The mean time from index arthroplasty to fracture was 9.5 weeks (range, 0 to 40 weeks). The majority of fractures occurred in the femoral diaphysis (59%). Nineteen fractures (66%) were displaced and 10 (34%) were nondisplaced or occult. The majority of cases were atraumatic in nature or involved minor trauma and were typically preceded by persistent leg pain. A transcortical pin trajectory, large pin diameter (&gt;4 mm), diaphyseal fixation, multiple placement attempts, and the use of non-self-drilling, non-self-tapping pins were the most commonly reported risk factors for pin-related periprosthetic fractures following CAN or RA TKA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Surgeons should maintain a high index of suspicion for pin-related fractures in patients with ongoing leg or thigh pain after CAN or RA TKA in order to avoid fracture displacement and additional morbidity. As CAN and RA TKA have unique complication risks, the debate regarding the value of technology-assisted TKA and its cost-effectiveness continues.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>\n                      Therapeutic\n                      <jats:underline>Level IV<\/jats:underline>\n                      . See Instructions for Authors for a complete description of levels of evidence.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.rvw.20.00091","type":"journal-article","created":{"date-parts":[[2021,1,26]],"date-time":"2021-01-26T17:39:19Z","timestamp":1611682759000},"page":"e20.00091","source":"Crossref","is-referenced-by-count":70,"title":["Periprosthetic Fractures Through Tracking Pin Sites Following Computer Navigated and Robotic Total and Unicompartmental Knee Arthroplasty"],"prefix":"10.2106","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1881-2766","authenticated-orcid":false,"given":"Tyler J.","family":"Smith","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9434-671X","authenticated-orcid":false,"given":"Ahmed","family":"Siddiqi","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Cleveland Clinic Foundation, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2815-3530","authenticated-orcid":false,"given":"Salvador A.","family":"Forte","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5861-779X","authenticated-orcid":false,"given":"Anthony","family":"Judice","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7050-5571","authenticated-orcid":false,"given":"Peter K.","family":"Sculco","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0308-9648","authenticated-orcid":false,"given":"Jonathan M.","family":"Vigdorchik","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Hospital for Special Surgery, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0681-7014","authenticated-orcid":false,"given":"Ran","family":"Schwarzkopf","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, New York University Langone Medical Center, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6198-5075","authenticated-orcid":false,"given":"Bryan D.","family":"Springer","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Atrium Musculoskeletal Institute, OrthoCarolina Hip and Knee Center, Charlotte, North Carolina"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,1]]},"reference":[{"issue":"1","key":"r1-20230807","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.arth.2012.04.026","article-title":"Long-term clinical outcomes and survivorship after total knee arthroplasty using a rotating platform knee prosthesis: a meta-analysis","volume":"28","author":"Hopley","year":"2013","journal-title":"J Arthroplasty"},{"issue":"4","key":"r2-20230807","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.arth.2009.04.018","article-title":"Twenty-year survivorship of cementless anatomic graduated component total knee arthroplasty","volume":"25","author":"Ritter","year":"2010","journal-title":"J Arthroplasty"},{"issue":"7","key":"r3-20230807","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/j.arth.2011.10.027","article-title":"Twenty-year survival analysis in total knee arthroplasty by a single surgeon","volume":"27","author":"Bae","year":"2012","journal-title":"J Arthroplasty"},{"issue":"4","key":"r4-20230807","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1007\/s12178-012-9139-6","article-title":"Assessing the value of a total joint replacement","volume":"5","author":"Bumpass","year":"2012","journal-title":"Curr Rev Musculoskelet Med"},{"key":"r5-20230807","doi-asserted-by":"crossref","first-page":"8987104","DOI":"10.1155\/2018\/8987104","article-title":"Revision surgery in total joint replacement is cost-intensive","volume":"2018","author":"Weber","year":"2018","journal-title":"Biomed Res Int"},{"issue":"3","key":"r6-20230807","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s12178-017-9415-6","article-title":"Technology in arthroplasty: are we improving value?","volume":"10","author":"Waddell","year":"2017","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"1","key":"r7-20230807","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.artd.2019.01.002","article-title":"Trends in computer navigation and robotic assistance for total knee arthroplasty in the United States: an analysis of patient and hospital factors","volume":"5","author":"Antonios","year":"2019","journal-title":"Arthroplast Today"},{"key":"r8-20230807","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/01.blo.0000148578.22729.0e","article-title":"Tibial component failure mechanisms in total knee arthroplasty","volume":"428","author":"Berend","year":"2004","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"r9-20230807","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1302\/0301-620X.73B5.1894655","article-title":"Coronal alignment after total knee replacement","volume":"73","author":"Jeffery","year":"1991","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"r10-20230807","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/j.arth.2017.11.033","article-title":"Technology-assisted hip and knee arthroplasties: an analysis of utilization trends","volume":"33","author":"Boylan","year":"2018","journal-title":"J Arthroplasty"},{"issue":"1","key":"r11-20230807","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s12178-011-9071-1","article-title":"Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome","volume":"4","author":"Desai","year":"2011","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"7","key":"r13-20230807","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.arth.2005.05.009","article-title":"Computer assisted navigation in total knee arthroplasty: comparison with conventional methods","volume":"20","author":"Anderson","year":"2005","journal-title":"J Arthroplasty"},{"issue":"5","key":"r14-20230807","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1302\/0301-620X.86B5.14927","article-title":"Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique","volume":"86","author":"B\u00e4this","year":"2004","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"r15-20230807","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1016\/j.arth.2011.04.037","article-title":"Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty","volume":"26","author":"Barrett","year":"2011","journal-title":"J Arthroplasty"},{"issue":"3","key":"r16-20230807","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1302\/0301-620X.86B3.14643","article-title":"Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial","volume":"86","author":"Chauhan","year":"2004","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"r17-20230807","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/j.arth.2005.04.004","article-title":"Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique","volume":"20","author":"Chin","year":"2005","journal-title":"J Arthroplasty"},{"key":"r18-20230807","doi-asserted-by":"crossref","first-page":"794827","DOI":"10.1155\/2013\/794827","article-title":"Robot-assisted navigation versus computer-assisted navigation in primary total knee arthroplasty: efficiency and accuracy","volume":"2013","author":"Clark","year":"2013","journal-title":"ISRN Orthop"},{"issue":"4","key":"r19-20230807","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.arth.2008.02.018","article-title":"Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty","volume":"24","author":"Choong","year":"2009","journal-title":"J Arthroplasty"},{"issue":"6","key":"r20-20230807","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1016\/j.arth.2011.12.028","article-title":"Meta-analysis of navigation vs conventional total knee arthroplasty","volume":"27","author":"Hetaimish","year":"2012","journal-title":"J Arthroplasty"},{"issue":"2","key":"r21-20230807","doi-asserted-by":"crossref","first-page":"236","DOI":"10.2106\/JBJS.F.00386","article-title":"A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation","volume":"89","author":"Matziolis","year":"2007","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"r22-20230807","doi-asserted-by":"crossref","first-page":"169","DOI":"10.4055\/cios.2017.9.2.169","article-title":"Robotic total knee arthroplasty with a cruciate-retaining implant: a 10-year follow-up study","volume":"9","author":"Yang","year":"2017","journal-title":"Clin Orthop Surg"},{"issue":"9","key":"r23-20230807","doi-asserted-by":"crossref","first-page":"2842","DOI":"10.1016\/j.arth.2017.03.073","article-title":"Pin site complications associated with computer-assisted navigation in hip and knee arthroplasty","volume":"32","author":"Kamara","year":"2017","journal-title":"J Arthroplasty"},{"issue":"8","key":"r24-20230807","doi-asserted-by":"crossref","first-page":"627","DOI":"10.2106\/JBJS.15.00664","article-title":"Improved accuracy of component positioning with robotic-assisted unicompartmental knee arthroplasty: data from a prospective, randomized controlled study","volume":"98","author":"Bell","year":"2016","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"r25-20230807","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.arth.2016.06.039","article-title":"Adoption of robotic vs fluoroscopic guidance in total hip arthroplasty: is acetabular positioning improved in the learning curve?","volume":"32","author":"Kamara","year":"2017","journal-title":"J Arthroplasty"},{"issue":"2","key":"r26-20230807","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1302\/0301-620X.88B2.16906","article-title":"Are systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial","volume":"88","author":"Kalairajah","year":"2006","journal-title":"J Bone Joint Surg Br"},{"issue":"12","key":"r27-20230807","doi-asserted-by":"crossref","first-page":"989","DOI":"10.2106\/JBJS.16.00791","article-title":"The clinical outcome of computer-navigated compared with conventional knee arthroplasty in the same patients: a prospective, randomized, double-blind, long-term study","volume":"99","author":"Kim","year":"2017","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"r28-20230807","doi-asserted-by":"crossref","first-page":"635","DOI":"10.2106\/JBJS.M.01496","article-title":"Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age","volume":"97","author":"de Steiger","year":"2015","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"r29-20230807","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.knee.2015.02.009","article-title":"Low incidence of complications in computer assisted total knee arthroplasty\u2014a retrospective review of 1596 cases","volume":"22","author":"Khakha","year":"2015","journal-title":"Knee"},{"issue":"3","key":"r30-20230807","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.otsr.2009.12.005","article-title":"Pin track induced fractures around computer-assisted TKA","volume":"96","author":"Beldame","year":"2010","journal-title":"Orthop Traumatol Surg Res"},{"issue":"SUPP_15","key":"r31-20230807","first-page":"218","article-title":"Tibial stress fracture after computer-navigated total knee arthroplasty","volume":"95-B","author":"Kim","year":"2013","journal-title":"Orthop Proceedings"},{"issue":"2","key":"r32-20230807","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.arth.2006.12.049","article-title":"Periprosthetic femoral supracondylar fracture after total knee arthroplasty with navigation system","volume":"23","author":"Li","year":"2008","journal-title":"J Arthroplasty"},{"issue":"5","key":"r33-20230807","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1007\/s00167-008-0485-2","article-title":"Intra-operative tibial fracture during computer assisted total knee replacement: a case report","volume":"16","author":"Manzotti","year":"2008","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"r34-20230807","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s10195-010-0096-9","article-title":"Tibial stress fracture after computer-navigated total knee arthroplasty","volume":"11","author":"Massai","year":"2010","journal-title":"J Orthop Traumatol"},{"issue":"5","key":"r35-20230807","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.knee.2006.06.002","article-title":"Femoral stress fracture after computer navigated total knee arthroplasty","volume":"13","author":"Ossendorf","year":"2006","journal-title":"Knee"},{"issue":"3","key":"r36-20230807","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.arth.2007.03.019","article-title":"Femoral fracture through a previous pin site after computer-assisted total knee arthroplasty","volume":"23","author":"Wysocki","year":"2008","journal-title":"J Arthroplasty"},{"issue":"1","key":"r37-20230807","first-page":"72","article-title":"Fatigue fracture of the femur after navigated total knee replacement","volume":"11","author":"Panasiuk","year":"2009","journal-title":"Ortop Traumatol Rehabil"},{"key":"r38-20230807","first-page":"2381406","article-title":"periprosthetic fracture through a unicortical tracking pin site after computer navigated total knee replacement","volume":"2018","author":"Blue","year":"2018","journal-title":"Case Rep Orthop"},{"issue":"6","key":"r39-20230807","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1007\/s11999-008-0150-6","article-title":"Case report: femoral shaft fracture resulting from femoral tracker placement in navigated TKA","volume":"466","author":"Bonutti","year":"2008","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"r40-20230807","doi-asserted-by":"crossref","first-page":"2120","DOI":"10.1016\/j.arth.2017.01.045","article-title":"Low incidence of postoperative complications with navigated total knee arthroplasty","volume":"32","author":"Brown","year":"2017","journal-title":"J Arthroplasty"},{"issue":"1","key":"r41-20230807","doi-asserted-by":"crossref","first-page":"8","DOI":"10.5704\/MOJ.1003.002","article-title":"Causative factors for femoral pin track fractures in navigated total knee arthroplasty","volume":"4","author":"Ewe","year":"2010","journal-title":"Malays Orthop J"},{"issue":"4","key":"r42-20230807","doi-asserted-by":"crossref","first-page":"188","DOI":"10.3109\/10929088.2011.586798","article-title":"Computer navigated total knee arthroplasty: aspects of a single unit\u2019s experience of 777 cases","volume":"16","author":"Harvie","year":"2011","journal-title":"Comput Aided Surg"},{"issue":"3","key":"r43-20230807","doi-asserted-by":"crossref","first-page":"504.e5","DOI":"10.1016\/j.arth.2010.05.009","article-title":"Tibial shaft stress fractures resulting from placement of navigation tracker pins","volume":"26","author":"Hoke","year":"2011","journal-title":"J Arthroplasty"},{"issue":"10","key":"r44-20230807","doi-asserted-by":"crossref","first-page":"2280","DOI":"10.2106\/00004623-200710000-00026","article-title":"Fractures associated with computer-navigated total knee arthroplasty. A report of two cases","volume":"89","author":"Jung","year":"2007","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"r45-20230807","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.arth.2010.01.006","article-title":"Delayed femoral fracture through a tracker pin site after navigated total knee arthroplasty","volume":"26","author":"Jung","year":"2011","journal-title":"J Arthroplasty"},{"key":"r46-20230807","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1097\/00003086-198706000-00020","article-title":"Supracondylar fracture of the femur after total knee arthroplasty","volume":"219","author":"Aaron","year":"1987","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"r47-20230807","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/0021-9290(90)90383-E","article-title":"Structural consequences of transcortical holes in long bones loaded in torsion","volume":"23","author":"Hipp","year":"1990","journal-title":"J Biomech"},{"issue":"2","key":"r48-20230807","doi-asserted-by":"crossref","first-page":"93","DOI":"10.3109\/10929080600668122","article-title":"Effect of one- and two-pin reference anchoring systems on marker stability during total knee arthroplasty computer navigation","volume":"11","author":"Mihalko","year":"2006","journal-title":"Comput Aided Surg"},{"issue":"2","key":"r49-20230807","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/0021-9290(91)90359-U","article-title":"The effect of defect size on the stress concentration and fracture characteristics for a tubular torsional model with a transverse hole","volume":"24","author":"Kuo","year":"1991","journal-title":"J Biomech"},{"issue":"4","key":"r50-20230807","first-page":"708","article-title":"Complications resulting from tracker pin-sites in computer navigated knee replacement surgery","volume":"81","author":"Thomas","year":"2015","journal-title":"Acta Orthop Belg"},{"issue":"3","key":"r51-20230807","doi-asserted-by":"crossref","first-page":"7067","DOI":"10.4081\/or.2017.7067","article-title":"Biomechanical analysis of four external fixation pin insertion techniques","volume":"9","author":"Arango","year":"2017","journal-title":"Orthop Rev (Pavia)"},{"issue":"8","key":"r52-20230807","doi-asserted-by":"crossref","first-page":"1639","DOI":"10.1016\/j.arth.2013.07.027","article-title":"Periprosthetic supracondylar femoral fractures above a total knee replacement: compatibility guide for fixation with a retrograde intramedullary nail","volume":"29","author":"Thompson","year":"2014","journal-title":"J Arthroplasty"},{"issue":"1","key":"r53-20230807","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1177\/230949901402200108","article-title":"Periprosthetic fractures after total knee arthroplasty","volume":"22","author":"Agarwal","year":"2014","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"7","key":"r54-20230807","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.injury.2012.01.025","article-title":"Outcome of periprosthetic distal femoral fractures following knee arthroplasty","volume":"43","author":"Hoffmann","year":"2012","journal-title":"Injury"},{"issue":"6","key":"r55-20230807","doi-asserted-by":"crossref","first-page":"591","DOI":"10.4103\/0019-5413.121586","article-title":"Outcome and incidence of periprosthetic supracondylar femoral fractures in TKA","volume":"47","author":"Singh","year":"2013","journal-title":"Indian J Orthop"},{"issue":"6","key":"r56-20230807","first-page":"1464","article-title":"Management and outcome of periprosthetic fractures after total knee arthroplasty","volume":"68","author":"Platzer","year":"2010","journal-title":"J Trauma"},{"issue":"1","key":"r57-20230807","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1186\/s12891-018-2250-0","article-title":"Periprosthetic tibial fractures in total knee arthroplasty - an outcome analysis of a challenging and underreported surgical issue","volume":"19","author":"Schreiner","year":"2018","journal-title":"BMC Musculoskelet Disord"},{"issue":"5","key":"r58-20230807","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.2106\/00004623-200605000-00036","article-title":"Revised grades of recommendation for summaries or reviews of orthopaedic surgical studies","volume":"88","author":"Wright","year":"2006","journal-title":"J Bone Joint Surg Am"}],"container-title":["JBJS Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.20.00091","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:35:38Z","timestamp":1787751338000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.20.00091"}},"subtitle":["A Systematic Review"],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.rvw.20.00091","relation":{},"ISSN":["2329-9185"],"issn-type":[{"value":"2329-9185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}