{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T05:46:36Z","timestamp":1791870396362,"version":"4.3.4"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Successful surgical management of pelvic ring and acetabular fractures requires technical expertise to achieve an accurate reduction and stable fixation. The use of 3-dimensional (3D) intraoperative imaging (3DIOI) as an assessment tool has led to improved reduction and placement of implants. The purpose of this study was to assess the utility of using 3DIOI in the management of acetabular and pelvic fractures on the basis of outcomes reported in the literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A literature search was performed using PubMed, the Cochrane Database of Systematic Reviews (CDSR), and Google Scholar using key terms. A network meta-analysis conducted using the frequentist approach allowed for statistical analysis of reported outcomes regarding screw position (in mm), fracture reduction (in mm), and complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 9 studies were included in this analysis. When compared with conventional radiography, the mean radiation dose (in cGy\u00b7cm\n                      <jats:sup>2<\/jats:sup>\n                      ) was significantly higher in 3DIOI (mean difference, 82.72; 95% confidence interval [CI], 21.83 to 143.61; p = 0.007). Use of 3DIOI yielded a 93% lower risk of developing medical complications (odds ratio [OR], 0.07; 95% CI, 0.02 to 0.35; p = 0.014). Use of 3DIOI yielded higher odds of achieving accurate screw placement (OR, 4.21; 95% CI, 1.44 to 12.32; p = 0.008) and perfect reduction (OR, 2.60; 95% CI, 1.19 to 5.68; p = 0.016). In ranking the imaging modalities, 12 of the 13 parameters analyzed were in favor of 3DIOI over conventional fluoroscopy and 2D navigation imaging.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Current literature supports the use of 3DIOI because of the decreased rates of misplaced implants, malreduced fractures, complications, and subsequent revision operations. The use of 3DIOI allows for improved visualization of pelvic anatomy when repairing pelvic and acetabular fractures, and helps surgeons to achieve favorable surgical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>\n                      Therapeutic\n                      <jats:underline>Level III<\/jats:underline>\n                      . See Instructions for Authors for a complete description of levels of evidence.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.rvw.20.00129","type":"journal-article","created":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T14:07:07Z","timestamp":1624543627000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Utility of 3-Dimensional Intraoperative Imaging in Pelvic and Acetabular Fractures"],"prefix":"10.2106","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2305-0249","authenticated-orcid":false,"given":"John J.","family":"Pisquiy","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery & Rehabilitation, Texas Tech University Health Sciences Center El Paso, El Paso, Texas"},{"name":"Department of Orthopaedics, West Virginia University School of Medicine, Morgantown, West Virginia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9267-3787","authenticated-orcid":false,"given":"Eman A.","family":"Toraih","sequence":"additional","affiliation":[{"name":"Department of Surgery, Tulane University, New Orleans, Louisiana"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8278-7094","authenticated-orcid":false,"given":"Mohammad H.","family":"Hussein","sequence":"additional","affiliation":[{"name":"Department of Surgery, Tulane University, New Orleans, Louisiana"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0495-9692","authenticated-orcid":false,"given":"Rami","family":"Khalifa","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery & Rehabilitation, Texas Tech University Health Sciences Center El Paso, El Paso, Texas"},{"name":"Department of Orthopaedics, Al Helal Hospital, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8027-2062","authenticated-orcid":false,"given":"Saad A.","family":"Shoulah","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Benha University School of Medicine, Benha, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0112-4147","authenticated-orcid":false,"given":"Amr","family":"Abdelgawad","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Maimonides Medical Center, Brooklyn, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6054-8586","authenticated-orcid":false,"given":"Ahmed M.","family":"Thabet","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery & Rehabilitation, Texas Tech University Health Sciences Center El Paso, El Paso, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,6]]},"reference":[{"issue":"6","key":"r1-20240906","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1016\/j.injury.2014.01.015","article-title":"Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation","volume":"45","author":"Takao","year":"2014","journal-title":"Injury"},{"issue":"6","key":"r2-20240906","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1007\/s00402-007-0411-y","article-title":"Value of 3D fluoroscopic imaging of acetabular fractures comparison to 2D fluoroscopy and CT imaging","volume":"128","author":"Kendoff","year":"2008","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"r3-20240906","doi-asserted-by":"crossref","first-page":"4019","DOI":"10.1016\/j.ejrad.2012.06.021","article-title":"Accuracy and consequences of 3D-fluoroscopy in upper and lower extremity fracture treatment: a systematic review","volume":"81","author":"Beerekamp","year":"2012","journal-title":"Eur J Radiol"},{"issue":"12","key":"r4-20240906","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1097\/BOT.0000000000000091","article-title":"Three-dimensional fluoroscopy-navigated percutaneous screw fixation of acetabular fractures","volume":"28","author":"Schwabe","year":"2014","journal-title":"J Orthop Trauma"},{"issue":"7","key":"r5-20240906","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.otsr.2016.07.005","article-title":"The added value of intraoperative CT scanner and screw navigation in displaced posterior wall acetabular fracture with articular impaction","volume":"102","author":"Sebaaly","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"issue":"10","key":"r6-20240906","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1007\/s00402-012-1555-y","article-title":"Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws","volume":"132","author":"Beck","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"issue":"25","key":"r7-20240906","doi-asserted-by":"crossref","first-page":"4353","DOI":"10.1002\/sim.6236","article-title":"Reduce dimension or reduce weights? Comparing two approaches to multi-arm studies in network meta-analysis","volume":"33","author":"R\u00fccker","year":"2014","journal-title":"Stat Med"},{"issue":"2","key":"r8-20240906","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1002\/jrsm.1045","article-title":"Consistency and inconsistency in network meta-analysis: model estimation using multivariate meta-regression","volume":"3","author":"White","year":"2012","journal-title":"Res Synth Methods"},{"issue":"7-8","key":"r9-20240906","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1002\/sim.3767","article-title":"Checking consistency in mixed treatment comparison meta-analysis","volume":"29","author":"Dias","year":"2010","journal-title":"Stat Med"},{"key":"r10-20240906","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/s12874-015-0060-8","article-title":"Ranking treatments in frequentist network meta-analysis works without resampling methods","volume":"15","author":"R\u00fccker","year":"2015","journal-title":"BMC Med Res Methodol"},{"issue":"1","key":"r11-20240906","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1186\/s13018-018-0780-7","article-title":"Intraoperative assessment of reduction and implant placement in acetabular fractures-limitations of 3D-imaging compared to computed tomography","volume":"13","author":"Keil","year":"2018","journal-title":"J Orthop Surg Res"},{"issue":"12","key":"r12-20240906","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/j.injury.2010.07.502","article-title":"Computer-assisted periacetabular screw placement: comparison of different fluoroscopy-based navigation procedures with conventional technique","volume":"41","author":"Ochs","year":"2010","journal-title":"Injury"},{"issue":"4","key":"r13-20240906","first-page":"926","article-title":"Computer-assisted surgery and intraoperative three-dimensional imaging for screw placement in different pelvic regions","volume":"71","author":"Grossterlinden","year":"2011","journal-title":"J Trauma"},{"issue":"9","key":"r14-20240906","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1007\/s00402-013-1788-4","article-title":"Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis","volume":"133","author":"Zwingmann","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"r15-20240906","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s11548-011-0652-7","article-title":"Evaluation of 2D and 3D navigation for iliosacral screw fixation","volume":"7","author":"Behrendt","year":"2012","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"8","key":"r16-20240906","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1097\/BOT.0b013e318234d443","article-title":"Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study","volume":"26","author":"Gras","year":"2012","journal-title":"J Orthop Trauma"},{"issue":"4","key":"r17-20240906","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1097\/TA.0b013e318254308f","article-title":"Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures","volume":"73","author":"Oberst","year":"2012","journal-title":"J Trauma Acute Care Surg"},{"issue":"3","key":"r18-20240906","doi-asserted-by":"crossref","first-page":"512","DOI":"10.2106\/00004623-200303000-00018","article-title":"Computed tomographic assessment of fractures of the posterior wall of the acetabulum after operative treatment","volume":"85","author":"Moed","year":"2003","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"r19-20240906","doi-asserted-by":"crossref","first-page":"684","DOI":"10.3109\/17453674.2015.1055690","article-title":"Open reduction and internal fixation aided by intraoperative 3-dimensional imaging improved the articular reduction in 72 displaced acetabular fractures","volume":"86","author":"Eckardt","year":"2015","journal-title":"Acta Orthop"},{"issue":"5","key":"r21-20240906","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1007\/s10278-020-00324-2","article-title":"Evaluation of software-based metal artifact reduction in intraoperative 3D imaging of the spine using a mobile cone beam CT","volume":"33","author":"Privalov","year":"2020","journal-title":"J Digit Imaging"},{"issue":"1S","key":"r22-20240906","doi-asserted-by":"crossref","first-page":"S19","DOI":"10.1016\/j.otsr.2019.05.021","article-title":"Role of 3D intraoperative imaging in orthopedic and trauma surgery","volume":"106","author":"Tonetti","year":"2020","journal-title":"Orthop Traumatol Surg Res"},{"issue":"8","key":"r23-20240906","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1016\/j.spinee.2013.10.019","article-title":"Economic study: a cost-effectiveness analysis of an intraoperative compared with a preoperative image-guided system in lumbar pedicle screw fixation in patients with degenerative spondylolisthesis","volume":"14","author":"Costa","year":"2014","journal-title":"Spine J"},{"issue":"8","key":"r25-20240906","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1007\/s00247-012-2396-0","article-title":"Dose optimisation for intraoperative cone-beam flat-detector CT in paediatric spinal surgery","volume":"42","author":"Petersen","year":"2012","journal-title":"Pediatr Radiol"}],"container-title":["JBJS Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.20.00129","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:43:56Z","timestamp":1787751836000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.20.00129"}},"subtitle":["A Network Meta-Analysis"],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":23,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.rvw.20.00129","relation":{},"ISSN":["2329-9185"],"issn-type":[{"value":"2329-9185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6]]}}}