{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:37:31Z","timestamp":1787755051828,"version":"build-2784847793"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:p>\n                    <jats:list list-type=\"plain\">\n                      <jats:list-item>\n                        <jats:p>\u00bb Radial head arthroplasty is a viable surgical option when a radial head fracture cannot be reconstructed. Radial head arthroplasty provides a load-bearing articular structure against the capitellum in unstable fractured elbows.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb Studies have emphasized the importance of choosing the correct implant size to replicate the native radial head anatomy, citing various consequences of improperly sized radial head prostheses. Overstuffing of the radiocapitellar joint, or lengthening of the radius, has been extensively studied because of its detrimental effects on elbow biomechanics, but other types of improper sizing also have negative consequences.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb In the setting of severe fracture-dislocation or revision surgery, anatomic landmarks that are useful for prosthesis sizing often are missing. Various methods have been described to provide guidance for the accurate sizing of a prosthetic radial head; a retrieved radial head, the proximal edge of the lesser sigmoid notch, the radiocapitellar synovial fold, and the ulnohumeral joint space all represent useful references.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb Intraoperative radiographic examination is an important step while assessing implant size, including the height of the prosthetic radial head.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb Since no single method is perfect on its own, the surgeon should combine as many reference measures as possible, both before and during the procedure, for accurate prosthesis sizing in order to achieve successful outcomes.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:p>","DOI":"10.2106\/jbjs.rvw.20.00178","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T23:22:03Z","timestamp":1619133723000},"source":"Crossref","is-referenced-by-count":11,"title":["Optimal Prosthesis Sizing for Radial Head Arthroplasty"],"prefix":"10.2106","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3027-3504","authenticated-orcid":false,"given":"Joshua J.","family":"Bagley","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Penn State Health Milton S. Hershey Medical Center, Hershey, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2229-9966","authenticated-orcid":false,"given":"Gregory J.","family":"Della Rocca","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7187-2891","authenticated-orcid":false,"given":"Matthew J.","family":"Smith","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5286-5335","authenticated-orcid":false,"given":"H. Mike","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,4]]},"reference":[{"issue":"8","key":"r2-20230807","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.2106\/00004623-200408000-00018","article-title":"The effect of radial head excision and arthroplasty on elbow kinematics and stability","volume":"86","author":"Beingessner","year":"2004","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"r3-20230807","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1016\/S0363-5023(03)00426-X","article-title":"The noncircular shape of the radial head","volume":"28","author":"van Riet","year":"2003","journal-title":"J Hand Surg Am"},{"issue":"10","key":"r5-20230807","doi-asserted-by":"crossref","first-page":"633","DOI":"10.5435\/JAAOS-22-10-633","article-title":"Radial head arthroplasty: state of the art","volume":"22","author":"Acevedo","year":"2014","journal-title":"J Am Acad Orthop Surg"},{"issue":"8","key":"r6-20230807","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.2106\/00004623-200108000-00010","article-title":"Arthroplasty with a metal radial head for unreconstructible fractures of the radial head","volume":"83","author":"Moro","year":"2001","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"r7-20230807","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1302\/0301-620X.92B5.23067","article-title":"Failure of metal radial head replacement","volume":"92","author":"van Riet","year":"2010","journal-title":"J Bone Joint Surg Br"},{"issue":"12","key":"r8-20230807","doi-asserted-by":"crossref","first-page":"2629","DOI":"10.2106\/00004623-200412000-00007","article-title":"Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow","volume":"86","author":"Van Glabbeek","year":"2004","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"r9-20230807","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.medengphy.2004.04.011","article-title":"The kinematic importance of radial neck length in radial head replacement","volume":"27","author":"Van Glabbeek","year":"2005","journal-title":"Med Eng Phys"},{"issue":"4","key":"r10-20230807","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.jhsa.2012.01.025","article-title":"Comparison of 2 forearm reconstructions for longitudinal radioulnar dissociation: a cadaver study","volume":"37","author":"Jones","year":"2012","journal-title":"J Hand Surg Am"},{"issue":"4","key":"r11-20230807","doi-asserted-by":"crossref","first-page":"e81","DOI":"10.2106\/JBJS.CC.15.00258","article-title":"Radial head arthroplasty understuffing in the setting of longitudinal radioulnar dissociation: a case report","volume":"6","author":"Jones","year":"2016","journal-title":"JBJS Case Connect"},{"issue":"8","key":"r12-20230807","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1016\/j.jhsa.2014.05.021","article-title":"Radiocapitellar joint contact pressures following radial head arthroplasty","volume":"39","author":"Cohn","year":"2014","journal-title":"J Hand Surg Am"},{"issue":"6","key":"r13-20230807","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1097\/BOT.0000000000000009","article-title":"The effect of radial head implant length on radiocapitellar articular properties and load transfer within the forearm","volume":"28","author":"Lanting","year":"2014","journal-title":"J Orthop Trauma"},{"issue":"2","key":"r14-20230807","doi-asserted-by":"crossref","first-page":"250","DOI":"10.2106\/00004623-198870020-00014","article-title":"Force transmission through the radial head","volume":"70","author":"Morrey","year":"1988","journal-title":"J Bone Joint Surg Am"},{"key":"r15-20230807","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.clinbiomech.2018.10.005","article-title":"The effect of radial head prosthesis diameter on posterolateral rotatory instability of the elbow","volume":"60","author":"Songy","year":"2018","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"5","key":"r16-20230807","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.clinbiomech.2015.03.012","article-title":"Radial head implant diameter: a biomechanical assessment of the forgotten dimension","volume":"30","author":"Lanting","year":"2015","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"7","key":"r17-20230807","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1007\/s00276-016-1625-x","article-title":"Validation of the contralateral side as reference for selecting radial head implant sizes","volume":"38","author":"Ten Berg","year":"2016","journal-title":"Surg Radiol Anat"},{"issue":"3","key":"r18-20230807","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s11751-012-0149-0","article-title":"The Essex-Lopresti lesion","volume":"7","author":"Wegmann","year":"2012","journal-title":"Strategies Trauma Limb Reconstr"},{"issue":"Suppl 1 Pt 2","key":"r20-20230807","doi-asserted-by":"crossref","first-page":"250","DOI":"10.2106\/JBJS.J.00356","article-title":"Determination of correct implant size in radial head arthroplasty to avoid overlengthening: surgical technique","volume":"92","author":"Athwal","year":"2010","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"r21-20230807","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.2106\/JBJS.ST.16.00093","article-title":"Treatment of radial head fractures with a modular metallic radial head replacement","volume":"7","author":"Longstaffe","year":"2017","journal-title":"JBJS Essent Surg Tech"},{"issue":"10","key":"r22-20230807","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1016\/j.jse.2013.04.005","article-title":"Selecting the diameter of a radial head implant: an assessment of local landmarks","volume":"22","author":"Alolabi","year":"2013","journal-title":"J Shoulder Elbow Surg"},{"issue":"12","key":"r23-20230807","doi-asserted-by":"crossref","first-page":"2364","DOI":"10.1016\/j.jhsa.2015.09.005","article-title":"Regional variations in cartilage thickness of the radial head: implications for prosthesis design","volume":"40","author":"Yeung","year":"2015","journal-title":"J Hand Surg Am"},{"issue":"3","key":"r24-20230807","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1302\/0301-620X.89B3.18099","article-title":"Validation of the lesser sigmoid notch of the ulna as a reference point for accurate placement of a prosthesis for the head of the radius: a cadaver study","volume":"89","author":"van Riet","year":"2007","journal-title":"J Bone Joint Surg Br"},{"issue":"11","key":"r25-20230807","doi-asserted-by":"crossref","first-page":"1970","DOI":"10.2106\/00004623-200211000-00010","article-title":"Radius pull test: predictor of longitudinal forearm instability","volume":"84","author":"Smith","year":"2002","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"r26-20230807","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jhsa.2005.06.012","article-title":"Reference points for radial head prosthesis size","volume":"31","author":"Doornberg","year":"2006","journal-title":"J Hand Surg Am"},{"issue":"7","key":"r27-20230807","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.2106\/JBJS.H.01161","article-title":"Determination of correct implant size in radial head arthroplasty to avoid overlengthening","volume":"91","author":"Frank","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"9","key":"r28-20230807","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1016\/j.jse.2018.02.070","article-title":"The radiocapitellar synovial fold: a lateral anatomic landmark for sizing radial head arthroplasty","volume":"27","author":"Lampley","year":"2018","journal-title":"J Shoulder Elbow Surg"},{"issue":"11","key":"r29-20230807","doi-asserted-by":"crossref","first-page":"1874","DOI":"10.1016\/j.jse.2016.04.014","article-title":"Intraoperative fluoroscopic assessment of proper prosthetic radial head height","volume":"25","author":"Kim","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"issue":"5","key":"r30-20230807","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.jhsa.2007.02.024","article-title":"Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing","volume":"32","author":"Rowland","year":"2007","journal-title":"J Hand Surg Am"},{"issue":"12","key":"r31-20230807","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s40001-016-0196-y","article-title":"Is the distal radioulnar variance useful for identification of radial head prosthesis overlengthening? A cadaver study","volume":"21","author":"Wegmann","year":"2016","journal-title":"Eur J Med Res"}],"container-title":["JBJS Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.20.00178","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:36:46Z","timestamp":1787751406000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.20.00178"}},"subtitle":["A Review of Current Evidence and Guidelines"],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":28,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.rvw.20.00178","relation":{},"ISSN":["2329-9185"],"issn-type":[{"value":"2329-9185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}