{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:40:14Z","timestamp":1787755214101,"version":"build-2784847793"},"reference-count":47,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    <jats:list list-type=\"plain\">\n                      <jats:list-item>\n                        <jats:p>\u00bb Conventional total hip arthroplasty (THA) largely remains an unguided procedure dependent on the ability and experience of the surgeon. New technologies, such as patient-specific instrumentation and robotics, have shown promising results in improving implant positioning, which has the potential to improve patient outcomes.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb The use of off-the-shelf (OTS) implant designs, however, limits the success of the technological advances since they are unable to recreate the native anatomy of the joint. The inability to restore femoral offset and version or the presence of implant-related leg-length discrepancies often lead to suboptimal surgical results that increase the risk of dislocation, fractures, and component wear, compromising postoperative functional outcomes and implant longevity.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb A customized THA system, whereby the femoral stem is designed to restore patient anatomy, has recently been introduced. The THA system uses computed tomography (CT)-derived 3D imaging to create a custom stem, patient-specific component placement, and patient-specific instrumentation that matches the patient\u2019s native anatomy.<\/jats:p>\n                      <\/jats:list-item>\n                      <jats:list-item>\n                        <jats:p>\u00bb The purpose of this article is to provide information on the design and manufacturing process of this new THA implant, to illustrate the associated preoperative planning, and to describe the surgical technique; 3 surgical cases are presented.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:p>","DOI":"10.2106\/jbjs.rvw.21.00078","type":"journal-article","created":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T16:00:49Z","timestamp":1658419249000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["THA with Use of Patient-Specific Resurfacing Jigs and a Novel Customized Implant Design"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5173-3069","authenticated-orcid":false,"given":"Matthew","family":"Zinner","sequence":"first","affiliation":[{"name":"Charles E. Schmidt College of Medicine, Boca Raton, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3966-2637","authenticated-orcid":false,"given":"Lennart","family":"Schroeder","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3886-0703","authenticated-orcid":false,"given":"Cyrus A.","family":"Pumilia","sequence":"additional","affiliation":[{"name":"College of Medicine, University of Central Florida, Orlando, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9048-3496","authenticated-orcid":false,"given":"Eric K.","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Personalized Orthopaedics of the Palm Beaches, Boynton Beach, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7264-8285","authenticated-orcid":false,"given":"Gregory","family":"Martin","sequence":"additional","affiliation":[{"name":"College of Medicine, University of Central Florida, Orlando, Florida"},{"name":"Department of Orthopedic Surgery, Personalized Orthopaedics of the Palm Beaches, Boynton Beach, Florida"},{"name":"University of Miami Leonard M. Miller School of Medicine, Miami, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,5]]},"reference":[{"issue":"4","key":"r1-20240731","doi-asserted-by":"crossref","first-page":"487","DOI":"10.2106\/00004623-200004000-00004","article-title":"Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up","volume":"82","author":"Callaghan","year":"2000","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"r2-20240731","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.arth.2010.03.013","article-title":"Predicting dissatisfaction after total hip arthroplasty: a study of 850 patients","volume":"26","author":"Anakwe","year":"2011","journal-title":"J Arthroplasty"},{"issue":"6","key":"r3-20240731","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1016\/j.arth.2019.01.075","article-title":"Patient Dissatisfaction After Primary Total Joint Arthroplasty: The Patient Perspective","volume":"34","author":"Halawi","year":"2019","journal-title":"J Arthroplasty"},{"issue":"17","key":"r4-20240731","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.2106\/JBJS.17.01617","article-title":"Projected Volume of Primary Total Joint Arthroplasty in the U.S., 2014 to 2030","volume":"100","author":"Sloan","year":"2018","journal-title":"J Bone Joint Surg Am"},{"issue":"12","key":"r5-20240731","doi-asserted-by":"crossref","first-page":"3573","DOI":"10.1016\/j.arth.2017.07.001","article-title":"Reported Litigation Associated With Primary Hip and Knee Arthroplasty","volume":"32","author":"Bokshan","year":"2017","journal-title":"J Arthroplasty"},{"issue":"6","key":"r6-20240731","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.arth.2007.05.003","article-title":"Medical malpractice in hip and knee arthroplasty","volume":"22","author":"Upadhyay","year":"2007","journal-title":"J Arthroplasty"},{"issue":"1","key":"r7-20240731","doi-asserted-by":"crossref","first-page":"7107","DOI":"10.1038\/s41598-020-62531-9","article-title":"Restoration of leg length and offset correlates with trochanteric pain syndrome in total hip arthroplasty","volume":"10","author":"Worlicek","year":"2020","journal-title":"Sci Rep"},{"issue":"6","key":"r8-20240731","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1302\/0301-620X.87B6.14745","article-title":"Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component","volume":"87","author":"Biedermann","year":"2005","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"r9-20240731","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.otsr.2009.03.010","article-title":"Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty","volume":"95","author":"Lecerf","year":"2009","journal-title":"Orthop Traumatol Surg Res"},{"issue":"5","key":"r10-20240731","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1016\/j.arth.2005.11.008","article-title":"Computed tomography measurement of the accuracy of component version in total hip arthroplasty","volume":"21","author":"Wines","year":"2006","journal-title":"J Arthroplasty"},{"issue":"11","key":"r11-20240731","doi-asserted-by":"crossref","first-page":"2598","DOI":"10.2106\/JBJS.H.01225","article-title":"A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty","volume":"91","author":"Dorr","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"r12-20240731","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/S1350-4533(03)00018-3","article-title":"CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning","volume":"25","author":"Viceconti","year":"2003","journal-title":"Med Eng Phys"},{"issue":"3","key":"r13-20240731","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1177\/1120700018776311","article-title":"Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty?","volume":"29","author":"Schiffner","year":"2019","journal-title":"Hip Int"},{"issue":"4","key":"r14-20240731","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.artd.2016.09.003","article-title":"Variance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography-based templating in primary total hip arthroplasty","volume":"3","author":"Osmani","year":"2017","journal-title":"Arthroplast Today"},{"issue":"2","key":"r15-20240731","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.otsr.2011.09.023","article-title":"Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating","volume":"98","author":"Sariali","year":"2012","journal-title":"Orthop Traumatol Surg Res"},{"issue":"19","key":"r16-20240731","doi-asserted-by":"crossref","first-page":"1760","DOI":"10.2106\/JBJS.L.01704","article-title":"Accuracy of acetabular component position in hip arthroplasty","volume":"95","author":"Barrack","year":"2013","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"r17-20240731","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s00402-007-0294-y","article-title":"Poor accuracy of freehand cup positioning during total hip arthroplasty","volume":"127","author":"Bosker","year":"2007","journal-title":"Arch Orthop Trauma Surg"},{"issue":"9","key":"r18-20240731","doi-asserted-by":"crossref","first-page":"2927","DOI":"10.1016\/j.arth.2018.05.004","article-title":"Does Intraoperative Fluoroscopy Improve Limb-Length Discrepancy and Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty?","volume":"33","author":"Bingham","year":"2018","journal-title":"J Arthroplasty"},{"issue":"20","key":"r19-20240731","doi-asserted-by":"crossref","first-page":"847","DOI":"10.5435\/JAAOS-D-19-00328","article-title":"Minimum 5-Year Outcomes of Robotic-assisted Primary Total Hip Arthroplasty With a Nested Comparison Against Manual Primary Total Hip Arthroplasty: A Propensity Score-Matched Study","volume":"28","author":"Domb","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"issue":"2","key":"r20-20240731","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.arth.2005.10.018","article-title":"Comparison of conventional versus computer-navigated acetabular component insertion","volume":"22","author":"Haaker","year":"2007","journal-title":"J Arthroplasty"},{"issue":"5","key":"r21-20240731","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.arth.2013.10.006","article-title":"Comparison of acetabular shell position using patient specific instruments vs. standard surgical instruments: a randomized clinical trial","volume":"29","author":"Small","year":"2014","journal-title":"J Arthroplasty"},{"issue":"10","key":"r22-20240731","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1302\/0301-620X.98B10.37808","article-title":"Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty","volume":"98-B","author":"Spencer-Gardner","year":"2016","journal-title":"Bone Joint J"},{"issue":"3","key":"r23-20240731","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1054\/arth.2002.30411","article-title":"Comparison of a mechanical acetabular alignment guide with computer placement of the socket","volume":"17","author":"Digioia","year":"2002","journal-title":"J Arthroplasty"},{"issue":"1","key":"r24-20240731","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1080\/17453670710014897","article-title":"High body mass index is associated with increased risk of implant dislocation following primary total hip replacement: 2,106 patients followed for up to 8 years","volume":"79","author":"Sadr Azodi","year":"2008","journal-title":"Acta Orthop"},{"issue":"7","key":"r25-20240731","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1007\/s00402-008-0686-7","article-title":"Cup positioning in THA: current status and pitfalls. A systematic evaluation of the literature","volume":"129","author":"Beckmann","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"issue":"235","key":"r26-20240731","first-page":"148","article-title":"The anatomic basis of femoral component design","author":"Noble","year":"1988","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"r27-20240731","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1007\/s11999-010-1487-1","article-title":"The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital","volume":"469","author":"Callanan","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"r28-20240731","first-page":"309","article-title":"Neck-modular femoral stems for total hip arthroplasty","volume":"20","author":"Goyal","year":"2010","journal-title":"Surg Technol Int"},{"issue":"8","key":"r29-20240731","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1302\/0301-620X.95B8.31525","article-title":"Modular neck femoral stems","volume":"95-B","author":"Krishnan","year":"2013","journal-title":"Bone Joint J"},{"issue":"9","key":"r30-20240731","first-page":"411","article-title":"Modular Versus Nonmodular Femoral Necks for Primary Total Hip Arthroplasty","volume":"44","author":"Carothers","year":"2015","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"4","key":"r31-20240731","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1054\/arth.2002.33263","article-title":"Soft tissue balancing: the hip","volume":"17","author":"Bourne","year":"2002","journal-title":"J Arthroplasty"},{"issue":"3","key":"r32-20240731","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1177\/1120700019836383","article-title":"Accuracy of leg length and femoral offset restoration after total hip arthroplasty with the utilisation of an intraoperative calibration gauge","volume":"30","author":"Enke","year":"2020","journal-title":"Hip Int"},{"key":"r33-20240731","first-page":"131","article-title":"Soft-tissue balancing of the hip: the role of femoral offset restoration","volume":"54","author":"Charles","year":"2005","journal-title":"Instr Course Lect"},{"issue":"4","key":"r34-20240731","doi-asserted-by":"crossref","first-page":"672","DOI":"10.3889\/oamjms.2019.088","article-title":"Templating Hip Arthroplasty","volume":"7","author":"Alnahhal","year":"2019","journal-title":"Open Access Maced J Med Sci"},{"issue":"2","key":"r35-20240731","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1302\/0301-620X.84B2.0840269","article-title":"A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating","volume":"84","author":"Conn","year":"2002","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"r36-20240731","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/0883-5403(94)90053-1","article-title":"Effect of rotation on the radiographic appearance of the femoral canal","volume":"9","author":"Eckrich","year":"1994","journal-title":"J Arthroplasty"},{"issue":"3","key":"r37-20240731","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1016\/j.ejrad.2009.11.024","article-title":"Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: radiation exposure and cost analysis","volume":"78","author":"Huppertz","year":"2011","journal-title":"Eur J Radiol"},{"issue":"10","key":"r38-20240731","doi-asserted-by":"crossref","first-page":"2353","DOI":"10.1016\/j.arth.2016.05.026","article-title":"Robotics in Arthroplasty: A Comprehensive Review","volume":"31","author":"Jacofsky","year":"2016","journal-title":"J Arthroplasty"},{"issue":"2","key":"r39-20240731","first-page":"66","article-title":"The Economic Value of Customized versus Off-the-Shelf Knee Implants in Medicare Fee-for-Service Beneficiaries","volume":"12","author":"O\u2019Connor","year":"2019","journal-title":"Am Health Drug Benefits"},{"issue":"4","key":"r40-20240731","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.artd.2017.05.001","article-title":"Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty","volume":"3","author":"Culler","year":"2017","journal-title":"Arthroplast Today"},{"issue":"7","key":"r41-20240731","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1016\/j.arth.2011.05.011","article-title":"Preoperative fluoroscopic imaging reduces variability of acetabular component positioning","volume":"26","author":"Nishikubo","year":"2011","journal-title":"J Arthroplasty"},{"issue":"11","key":"r42-20240731","doi-asserted-by":"crossref","first-page":"e970","DOI":"10.3928\/01477447-20151020-04","article-title":"Intraoperative Fluoroscopy Improves Component Position During Anterior Hip Arthroplasty","volume":"38","author":"Jennings","year":"2015","journal-title":"Orthopedics"},{"issue":"1","key":"r43-20240731","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.artd.2019.11.006","article-title":"Does the use of intraoperative fluoroscopy improve postoperative radiographic component positioning and implant size in total hip arthroplasty utilizing a direct anterior approach?","volume":"6","author":"Holst","year":"2019","journal-title":"Arthroplast Today"},{"issue":"17","key":"r44-20240731","doi-asserted-by":"crossref","first-page":"1913","DOI":"10.1097\/BRS.0b013e31817bb130","article-title":"Sterility of C-arm fluoroscopy during spinal surgery","volume":"33","author":"Biswas","year":"2008","journal-title":"Spine (Phila Pa 1976"},{"issue":"12","key":"r45-20240731","doi-asserted-by":"crossref","first-page":"e471","DOI":"10.1097\/BOT.0000000000001592","article-title":"The Far Side Opposite the Surgeon is Most Prone to Contamination From the C-Arm","volume":"33","author":"Zuelzer","year":"2019","journal-title":"J Orthop Trauma"},{"issue":"4","key":"r46-20240731","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1016\/j.arth.2012.12.001","article-title":"The use of patient-specific instrumentation improves the accuracy of acetabular component placement","volume":"28","author":"Buller","year":"2013","journal-title":"J Arthroplasty"},{"issue":"4","key":"r47-20240731","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.arth.2004.01.016","article-title":"Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty","volume":"20","author":"Asayama","year":"2005","journal-title":"J Arthroplasty"}],"container-title":["JBJS Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.21.00078","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:39:20Z","timestamp":1787751560000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.21.00078"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":47,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.rvw.21.00078","relation":{},"ISSN":["2329-9185"],"issn-type":[{"value":"2329-9185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5]]}}}