{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T18:39:48Z","timestamp":1792435188851,"version":"4.5.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Metal hypersensitivity reactions are infrequently reported but clinically significant after spinal implant surgery. Clinical presentation can mimic infection or mechanical failure, making diagnosis difficult. Evidence to guide diagnosis and management is largely limited to short case series and case reports. The purpose of this study was to systematically review the clinical presentation, diagnostic methods, and outcomes of metal hypersensitivity associated with spinal implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A systematic review was conducted of PubMed, Embase, and Scopus from inception through June 22, 2026, in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Title and abstract screening, full-text review, and data extraction were performed independently by 2 reviewers with conflicts resolved by a third reviewer. Eligible studies included adult patients with suspected or confirmed metal hypersensitivity following spinal implant surgery that reported patient-level clinical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Fifteen studies with a total of 19 patients met inclusion criteria (53% female, 42% male, and 5% not reported). The median patient age was 47 years (range, 19-69). Twelve procedures (63%) were fusion-based, while 7 (37%) were motion preserving, including disk arthroplasty and artificial facet replacement systems. Common clinical presentations included persistent pain, with 8 patients (42%) exhibiting dermatologic manifestations. Metal hypersensitivity was immunologically confirmed by positive patch testing and\/or lymphocyte transformation testing in 11 patients (58%), while 8 (42%) were diagnosed clinically. Onset of symptoms ranged from immediately postoperatively to 15 years after implantation. Eighteen patients underwent removal or revision with clinical improvement in 14 of 16 with a reported outcome (88%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Metal hypersensitivity reactions following spinal implants are infrequently reported but may present either immediately or in a delayed manner with symptoms that mimic more common postoperative complications, such as infection or pseudarthrosis, or may present with dermatologic manifestations. In cases where other etiologies are ruled out, hardware removal was frequently, though not invariably, associated with clinical improvement, which was reported narratively rather than by validated outcome measures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>\n                      Therapeutic\n                      <jats:underline>Level V<\/jats:underline>\n                      . See Instructions for Authors for a complete description of levels of evidence.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.rvw.26.00099","type":"journal-article","created":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T18:00:33Z","timestamp":1792432833000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Metal Hypersensitivity Reactions Following Spinal Implants"],"prefix":"10.2106","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-3325-9602","authenticated-orcid":false,"given":"Joseph","family":"Abbo","sequence":"first","affiliation":[{"name":"University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-8736-3347","authenticated-orcid":false,"given":"Jacob","family":"Thomas","sequence":"additional","affiliation":[{"name":"Oakland University William Beaumont School of Medicine, Rochester, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2154-8170","authenticated-orcid":false,"given":"Christian","family":"Stipho","sequence":"additional","affiliation":[{"name":"University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3773-3710","authenticated-orcid":false,"given":"Erik","family":"Nakken","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2726-181X","authenticated-orcid":false,"given":"Rakesh","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6859-6478","authenticated-orcid":false,"given":"Joshua D.","family":"Piche","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4818-8578","authenticated-orcid":false,"given":"IIyas","family":"Aleem","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,10]]},"reference":[{"issue":"1","key":"r1-20261019","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1007\/s13555-016-0162-1","article-title":"Metal hypersensitivity reactions to orthopedic implants","volume":"7","author":"Teo","year":"2017","journal-title":"Dermatol Ther"},{"issue":"2","key":"r2-20261019","doi-asserted-by":"crossref","first-page":"215","DOI":"10.5114\/ada.2023.127640","article-title":"Metal hypersensitivity in hip, knee and spine surgery","volume":"40","author":"P\u0142usa","year":"2023","journal-title":"Adv Dermatol Allergol"},{"issue":"1","key":"r3-20261019","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s42836-023-00227-x","article-title":"Understanding immune-mediated cobalt\/chromium allergy to orthopaedic implants: a meta-synthetic review","volume":"6","author":"Chen","year":"2024","journal-title":"Arthroplasty"},{"issue":"9","key":"r4-20261019","doi-asserted-by":"crossref","first-page":"3269","DOI":"10.1002\/ksa.12706","article-title":"Metal sensitivity in total joint arthroplasty: none of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!","volume":"33","author":"Longo","year":"2025","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"r5-20261019","doi-asserted-by":"crossref","first-page":"e25.00252","DOI":"10.2106\/JBJS.OA.25.00252","article-title":"Metal allergies in total shoulder arthroplasty: a scoping review and clinical update","volume":"11","author":"Haase","year":"2026","journal-title":"JBJS Open Access"},{"issue":"2","key":"r6-20261019","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1007\/s00586-011-2043-8","article-title":"Mechanical implant failure in posterior cervical spine fusion","volume":"21","author":"Okamoto","year":"2012","journal-title":"Eur Spine J"},{"key":"r7-20261019","doi-asserted-by":"crossref","first-page":"1282573","DOI":"10.3389\/fcell.2023.1282573","article-title":"The role and mechanism of inflammatory response to growing rod implantation in early onset scoliosis","volume":"11","author":"Zhang","year":"2023","journal-title":"Front Cell Dev Biol"},{"issue":"4","key":"r8-20261019","doi-asserted-by":"crossref","first-page":"461","DOI":"10.5152\/j.aott.2020.20148","article-title":"A rare case of delayed hypersensitivity reaction to metal ions secondary to a remnant pedicle screw fragment after spinal arthrodesis","volume":"54","author":"Kim","year":"2020","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"10","key":"r9-20261019","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1007\/s00701-012-1466-2","article-title":"Allergy to implants in lumbar screw fixation mimics postsurgical wound infection","volume":"154","author":"El Habony","year":"2012","journal-title":"Acta Neurochir (Wien)"},{"issue":"8","key":"r10-20261019","first-page":"e28293","article-title":"Cervical implant allergy with chronic neck pain: a case report","volume":"14","author":"Aoyama","year":"2022","journal-title":"Cureus"},{"issue":"5","key":"r11-20261019","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/j.otsr.2015.05.005","article-title":"Delayed hypersensitivity reaction after cervical disc replacement: a case report","volume":"101","author":"Lagier","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"issue":"3","key":"r12-20261019","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/MAJ.0b013e318141f723","article-title":"Drug rash with eosinophilia and systemic symptoms (DRESS) syndrome: suspected association with titanium bioprosthesis","volume":"334","author":"Nawaz","year":"2007","journal-title":"Am J Med Sci"},{"key":"r13-20261019","doi-asserted-by":"crossref","first-page":"635","DOI":"10.25259\/SNI_1139_2021","article-title":"Metal allergy hypersensitivity after posterior thoracic spinal fusion: a case report and review of the literature","volume":"12","author":"Saini","year":"2021","journal-title":"Surg Neurol Int"},{"key":"r14-20261019","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.wneu.2020.04.093","article-title":"Metal hypersensitivity after spinal instrumentation: when to suspect and how to treat","volume":"139","author":"Curley","year":"2020","journal-title":"World Neurosurg"},{"issue":"1","key":"r15-20261019","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1186\/1471-2474-15-314","article-title":"Metal hypersensitivity in patient with posterior lumbar spine fusion: a case report and its literature review","volume":"15","author":"Shang","year":"2014","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"r16-20261019","first-page":"e7109","article-title":"Rare systemic response to titanium spinal fusion implant: case report","volume":"12","author":"Towers","year":"2020","journal-title":"Cureus"},{"issue":"4","key":"r17-20261019","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1080\/02688697.2020.1718605","article-title":"Suspected allergy to titanium after anterior cervical discectomy and fusion using a Zero-P device: a case report","volume":"37","author":"Shi","year":"2023","journal-title":"Br J Neurosurg"},{"issue":"5","key":"r18-20261019","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1097\/DER.0000000000000846","article-title":"Titanium hypersensitivity diagnosed by patch testing after anterior cervical spine fusion","volume":"33","author":"Estupi\u00f1an","year":"2022","journal-title":"Dermatitis"},{"issue":"3","key":"r19-20261019","doi-asserted-by":"crossref","first-page":"548","DOI":"10.4103\/neurol-india.Neurol-India-D-25-00635","article-title":"Extrusion of spinal implants through the overlying skin: a rare epiphenomenon of metal allergy","volume":"74","author":"Baral","year":"2026","journal-title":"Neurology India"},{"issue":"5","key":"r20-20261019","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.neuchi.2022.05.006","article-title":"Confirmed titanium hypersensitivity causing the failure of a lumbar spine fusion","volume":"68","author":"Wang","year":"2022","journal-title":"Neurochirurgie"},{"issue":"1","key":"r21-20261019","doi-asserted-by":"crossref","first-page":"81","DOI":"10.3171\/2017.10.SPINE17862","article-title":"Failure of facet replacement system with metal-on-metal bearing surface and subsequent discovery of cobalt allergy: report of 2 cases","volume":"29","author":"Goodwin","year":"2018","journal-title":"J Neurosurg Spine"},{"issue":"7","key":"r22-20261019","doi-asserted-by":"crossref","first-page":"E492","DOI":"10.1097\/BRS.0b013e31820ea9a2","article-title":"Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases","volume":"36","author":"Guyer","year":"2011","journal-title":"Spine (Phial Pa 1976)"},{"issue":"4","key":"r23-20261019","first-page":"19","article-title":"Retrospective analysis of adverse reactions to metal-on-metal lumbar disc arthroplasties in 378 consecutive patients","volume":"13","author":"Berg","year":"2014","journal-title":"SA Orthop J"}],"container-title":["JBJS Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.26.00099","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T18:00:37Z","timestamp":1792432837000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.RVW.26.00099"}},"subtitle":["A Systematic Review"],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":23,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.rvw.26.00099","relation":{},"ISSN":["2329-9185","2329-9185"],"issn-type":[{"value":"2329-9185","type":"electronic"},{"value":"2329-9185","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]}}}