{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T16:45:56Z","timestamp":1792514756319,"version":"4.5.0"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>\n                      Preoperative planning software and a robotic device facilitate the placement of pedicle screws, especially in patients with difficult anatomy, thereby increasing the feasibility, accuracy, and efficiency of the procedure. The robot functions as a semiactive surgical assistive device whose goal is not to substitute but to offer the surgeon a set of versatile tools that can broaden his or her ability to treat patients\n                      <jats:sup>1<\/jats:sup>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Description:<\/jats:title>\n                    <jats:p>\n                      The robotic guidance system consists of a bed-mounted surgical arm and a workstation. We used the Mazor X Stealth Edition Robotic Guidance System by Medtronic for spine surgery, which has been previously described\n                      <jats:sup>2\u20135<\/jats:sup>\n                      . Unlike other systems that are navigation-based and require an optical tracking mechanism, this system relies on the preoperative plan to be referenced using the intraoperative registration. The workstation runs an interface software that facilitates preoperative planning, intraoperative image acquisition and registration, kinematic calculations, and real-time robot motion control. The robotic arm is mounted onto the bed as well as rigidly attached to the patient\u2019s spine. It can move in 6 degrees of freedom to provide the preplanned screw trajectory and entry point thereby allowing the surgeon to manually perform the drilling and screw insertion through either an open or percutaneous procedure by first seating a drill tube and then drilling and tapping the hole as needed.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Alternatives:<\/jats:title>\n                    <jats:p>\n                      Other robotic systems include the ROSA robot by Medtech, the ExcelsiusGPS robot by Globus Medical, and the SurgiBot and ALF\u2010X Surgical Robotic systems (both from TransEnterix). The Da Vinci Surgical System (Intuitive Surgical) has been utilized for laparoscopic anterior lumbar interbody fusion (ALIF), but it has not been approved by the U.S. Food and Drug Administration for actual spinal instrumentation. Alternative surgical techniques for pedicle screw placement include the freehand fluoroscopy-guided technique and intraoperative image-assisted computer navigation techniques, including isocentric C-arm (Iso-C) 3D (3-dimensional) navigation (Siemens), computed tomography (CT) navigation, O-arm navigation (Medtronic), CT-magnetic resonance imaging co-registration technology, and a 3D-visual guidance technique\n                      <jats:sup>6\u20138<\/jats:sup>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Rationale:<\/jats:title>\n                    <jats:p>\n                      The robotic-guided pedicle screw placement offers the following benefits over conventional dorsal instrumentation techniques: improved accuracy and safety in pedicle screw insertion\n                      <jats:sup>2\u20134,9\u201313<\/jats:sup>\n                      ; precision in screw size selection and planned screw positioning\n                      <jats:sup>2<\/jats:sup>\n                      ; a reduction in exposure to radiation for the surgeon, the patient, and the operating-room staff\n                      <jats:sup>9,11,12,14\u201319<\/jats:sup>\n                      ; simplicity and user-friendliness with a moderate learning curve\n                      <jats:sup>10,11,20,21<\/jats:sup>\n                      ; ease of registration and reduction of operating time\n                      <jats:sup>2<\/jats:sup>\n                      ; significant enhancement of the surgeon\u2019s ergonomics and dexterity for repetitive tasks in pedicle screw placement\n                      <jats:sup>15,22\u201324<\/jats:sup>\n                      ; and a wider coverage in function to include utilization during minimally invasive surgery where applicable\n                      <jats:sup>11,25<\/jats:sup>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Expected Outcomes:<\/jats:title>\n                    <jats:p>\n                      Accuracy rates between 94.5% and 99%, comparable with those in our study\n                      <jats:sup>10<\/jats:sup>\n                      , have been reported with the robotic-guided pedicle screw insertion technique, even in studies involving complex deformities and revision surgeries for congenital malformations, degenerative disorders, destructive tumors, and trauma\n                      <jats:sup>2\u20134,9\u201313<\/jats:sup>\n                      . The safety of this technique, in terms of reduced complications and intraoperative radiation exposure, has also been documented as higher than that for freehand fluoroscopic guidance or other navigation techniques\n                      <jats:sup>9,11,12,14\u201319<\/jats:sup>\n                      . The feasibility of this procedure has been further extended to minimally invasive procedures and to use in the cervical region, with replication of its advantages. It is associated with a reasonable learning curve, with consistent successful results after 25 to 30 patients.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Important Tips:<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>The principles of robotic-guided pedicle screw placement are similar irrespective of the system used.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Although initially utilized mainly for thoracolumbar pedicle screw insertion, the latest robots and software have been adapted for use in the cervical spine with equivalent efficiency and accuracy.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Robotic guidance can be employed in non-pedicle-screw-insertion procedures.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Challenges include radiation exposure, trajectory failure, equipment and software failure, failed registration, logistics, time, and high cost.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2106\/jbjs.st.19.00020","type":"journal-article","created":{"date-parts":[[2020,5,26]],"date-time":"2020-05-26T00:03:13Z","timestamp":1590451393000},"page":"e0020-e0020","source":"Crossref","is-referenced-by-count":133,"title":["Robotic-Assisted Pedicle Screw Placement During Spine Surgery"],"prefix":"10.2106","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6889-6136","authenticated-orcid":false,"given":"Isador H.","family":"Lieberman","sequence":"first","affiliation":[{"name":"Scoliosis and Spine Tumor Center, Texas Back Institute, Plano, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5914-6130","authenticated-orcid":false,"given":"Stanley","family":"Kisinde","sequence":"additional","affiliation":[{"name":"Scoliosis and Spine Tumor Center, Texas Back Institute, Plano, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9312-0850","authenticated-orcid":false,"given":"Shea","family":"Hesselbacher","sequence":"additional","affiliation":[{"name":"Scoliosis and Spine Tumor Center, Texas Back Institute, Plano, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020]]},"reference":[{"issue":"3","key":"bib2-20230808","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1227\/01.NEU.0000229055.00829.5B","article-title":"Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I\u2014technical development and a test case result","volume":"59","author":"Lieberman","year":"2006","journal-title":"Neurosurgery."},{"issue":"24","key":"bib3-20230808","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1097\/BRS.0b013e3181d323ab","article-title":"Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study","volume":"35","author":"Devito","year":"2010","journal-title":"Spine."},{"issue":"4","key":"bib4-20230808","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/BRS.0b013e318191ed32","article-title":"Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement","volume":"34","author":"Pechlivanis","year":"2009","journal-title":"Spine."},{"issue":"2","key":"bib5-20230808","first-page":"ONS129","article-title":"Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2\u2014evaluation of system accuracy","volume":"60","author":"Togawa","year":"2007","journal-title":"Neurosurgery."},{"issue":"3S","key":"bib6-20230808","doi-asserted-by":"crossref","first-page":"S86","DOI":"10.1093\/neuros\/nyw077","article-title":"Navigation and robotics in spinal surgery: where are we now?","volume":"80","author":"Overley","year":"2017","journal-title":"Neurosurgery."},{"issue":"1","key":"bib7-20230808","doi-asserted-by":"crossref","first-page":"2309499016684090","DOI":"10.1177\/2309499016684090","article-title":"Comparison of intraoperative O-arm- and conventional fluoroscopy (C-arm)-assisted insertion of pedicle screws in the treatment of fracture of thoracic vertebrae","volume":"25","author":"Liu","year":"2017","journal-title":"J Orthop Surg (Hong Kong)."},{"issue":"5","key":"bib8-20230808","doi-asserted-by":"crossref","first-page":"479","DOI":"10.3171\/2011.6.SPINE10721","article-title":"A novel cost-effective computer-assisted imaging technology for accurate placement of thoracic pedicle screws","volume":"15","author":"Abe","year":"2011","journal-title":"J Neurosurg Spine."},{"issue":"6","key":"bib9-20230808","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1007\/s00586-011-1729-2","article-title":"Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement","volume":"20","author":"Kantelhardt","year":"2011","journal-title":"Eur Spine J."},{"issue":"3","key":"bib10-20230808","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/s00586-012-2499-1","article-title":"Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients","volume":"22","author":"Hu","year":"2013","journal-title":"Eur Spine J."},{"issue":"5","key":"bib11-20230808","doi-asserted-by":"crossref","first-page":"E14","DOI":"10.3171\/2017.3.FOCUS179","article-title":"Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery","volume":"42","author":"Molliqaj","year":"2017","journal-title":"Neurosurg Focus."},{"issue":"Suppl 1","key":"bib12-20230808","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1227\/NEU.0b013e318270d02c","article-title":"Spinal robotics: current applications and future perspectives","volume":"72","author":"Roser","year":"2013","journal-title":"Neurosurgery."},{"issue":"17","key":"bib13-20230808","doi-asserted-by":"crossref","first-page":"E986","DOI":"10.1097\/BRS.0000000000000960","article-title":"Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy","volume":"40","author":"van Dijk","year":"2015","journal-title":"Spine."},{"issue":"2","key":"bib14-20230808","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/BRS.0000000000000100","article-title":"Robot-assisted vertebral body augmentation: a radiation reduction tool","volume":"39","author":"Barzilay","year":"2014","journal-title":"Spine."},{"key":"bib15-20230808","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1007\/978-3-211-99651-5_38","article-title":"Robotic technology in spine surgery: current applications and future developments","volume":"109","author":"St\u00fcer","year":"2011","journal-title":"Acta Neurochir Suppl (Wien)."},{"issue":"5","key":"bib16-20230808","doi-asserted-by":"crossref","first-page":"E2","DOI":"10.3171\/2017.2.FOCUS16544","article-title":"Current applications of robotics in spine surgery: a systematic review of the literature","volume":"42","author":"Joseph","year":"2017","journal-title":"Neurosurg Focus."},{"issue":"6","key":"bib17-20230808","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/BRS.0000000000001778","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial","volume":"42","author":"Hyun","year":"2017","journal-title":"Spine."},{"issue":"5","key":"bib18-20230808","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/2017.2.FOCUS16552","article-title":"Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws","volume":"42","author":"Keric","year":"2017","journal-title":"Neurosurg Focus."},{"issue":"4","key":"bib19-20230808","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/s12240-010-0031-1","article-title":"Why do I use and recommend the use of navigation?","volume":"22","author":"Schoenmayr","year":"2010","journal-title":"ArgoSpine News J."},{"issue":"2","key":"bib20-20230808","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/BRS.0000000000000680","article-title":"Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test","volume":"40","author":"Kim","year":"2015","journal-title":"Spine."},{"issue":"10","key":"bib21-20230808","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1007\/s00701-015-2535-0","article-title":"Unskilled unawareness and the learning curve in robotic spine surgery","volume":"157","author":"Schatlo","year":"2015","journal-title":"Acta Neurochir (Wien)."},{"key":"bib22-20230808","first-page":"136","article-title":"Neurosurgical robotics","volume":"49","author":"Kelly","year":"2002","journal-title":"Clin Neurosurg."},{"issue":"3","key":"bib23-20230808","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1227\/01.NEU.0000108638.05274.E9","article-title":"Surgical robotics: a review and neurosurgical prototype development","volume":"54","author":"Louw","year":"2004","journal-title":"Neurosurgery."},{"issue":"8","key":"bib25-20230808","doi-asserted-by":"crossref","first-page":"E496","DOI":"10.1097\/BRS.0b013e31824b7767","article-title":"Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation","volume":"37","author":"Ringel","year":"2012","journal-title":"Spine."},{"key":"bib26-20230808","doi-asserted-by":"crossref","first-page":"1","DOI":"10.14444\/2001","article-title":"Robotic assisted surgeries for the treatment of spine tumors","volume":"9","author":"Hu","year":"2015","journal-title":"Int J Spine Surg."},{"issue":"2","key":"bib27-20230808","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1002\/rcs.86","article-title":"Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist","volume":"2","author":"Sukovich","year":"2006","journal-title":"Int J Med Robot."},{"issue":"6","key":"bib28-20230808","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1007\/s11999-013-3291-1","article-title":"What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?","volume":"472","author":"Hu","year":"2014","journal-title":"Clin Orthop Relat Res."},{"key":"bib29-20230808","doi-asserted-by":"crossref","first-page":"152S","DOI":"10.1016\/j.spinee.2007.07.362","article-title":"P152. Radiation exposure using miniature robotic guidance for spinal surgery","volume":"7","author":"Lieberman","year":"2007","journal-title":"Spine J."},{"issue":"11","key":"bib30-20230808","doi-asserted-by":"crossref","first-page":"E465","DOI":"10.1097\/BRS.0b013e3181d1021a","article-title":"Complications of pedicle screw fixation in scoliosis surgery: a systematic review","volume":"35","author":"Hicks","year":"2010","journal-title":"Spine."},{"issue":"2","key":"bib31-20230808","doi-asserted-by":"crossref","first-page":"N20","DOI":"10.1227\/01.neu.0000417535.07871.36","article-title":"Evaluating the accuracy of robotic assistance in spine surgery","volume":"71","author":"Cahill","year":"2012","journal-title":"Neurosurgery."},{"issue":"6","key":"bib32-20230808","doi-asserted-by":"crossref","first-page":"636","DOI":"10.3171\/2014.3.SPINE13714","article-title":"Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison","volume":"20","author":"Schatlo","year":"2014","journal-title":"J Neurosurg Spine."},{"issue":"2","key":"bib33-20230808","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s11934-006-0071-4","article-title":"Learning curve using robotic surgery","volume":"7","author":"Kaul","year":"2006","journal-title":"Curr Urol Rep."},{"issue":"6","key":"bib34-20230808","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1007\/s00586-002-0469-8","article-title":"Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations","volume":"11","author":"Jutte","year":"2002","journal-title":"Eur Spine J."},{"issue":"3","key":"bib35-20230808","doi-asserted-by":"crossref","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","article-title":"Pedicle screw placement accuracy: a meta-analysis","volume":"32","author":"Kosmopoulos","year":"2007","journal-title":"Spine."},{"issue":"6","key":"bib36-20230808","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1007\/s00586-010-1577-5","article-title":"Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies","volume":"20","author":"Tian","year":"2011","journal-title":"Eur Spine J."}],"container-title":["JBJS Essential Surgical Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.ST.19.00020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:46:40Z","timestamp":1787752000000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2106\/JBJS.ST.19.00020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":34,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2106\/jbjs.st.19.00020","relation":{},"ISSN":["2160-2204"],"issn-type":[{"value":"2160-2204","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}