{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"Research Square"}],"indexed":{"date-parts":[[2024,3,3]],"date-time":"2024-03-03T13:34:21Z","timestamp":1709472861512},"posted":{"date-parts":[[2023,6,6]]},"group-title":"In Review","reference-count":28,"publisher":"Research Square Platform LLC","license":[{"start":{"date-parts":[[2023,6,6]],"date-time":"2023-06-06T00:00:00Z","timestamp":1686009600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2023,5,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>This study aimed to evaluate agreement of Wide scan measurements from swept-source optical coherence tomography(SS-OCT) Triton and spectral-domain OCT(SD-OCT) Maestro in normal\/glaucoma eyes, and to assess the precision of measurements from Wide and Cube scans of both devices. Three Triton and three Maestro operator\/device configurations were created by pairing three operators, with study eye and testing order randomized. Three scans were captured for Wide (12mm\u00d79mm), Macular Cube (7mmx7mm\u2013Triton; 6mmx6mm-Maestro), and Optic Disc Cube (6mmx6mm) scans for 25 normal eyes and 25 glaucoma eyes. Thickness of circumpapillary retinal nerve fiber layer(cpRNFL), ganglion cell layer+inner plexiform layer(GCL+), and ganglion cell complex(GCL++) was obtained from each scan. A two-way random effect analysis of variance model was used to estimate the repeatability and reproducibility; agreement was evaluated by Bland-Altman analysis and Deming regression. Precision limit estimates were low: &lt;5\u00b5m for macular and &lt;10\u00b5m for optic disc parameters. Precision for Wide and Cube scans of both devices were comparablein both groups. Excellent agreement between the two devices was found for Wide scans, with the mean difference&lt;3\u00b5m across all measurements (cpRNFL&lt;3\u00b5m, GCL+&lt;2\u00b5m, GCL++&lt;1\u00b5m), indicating interoperability. A single Wide scan covering the peripapillary and macular regions may be useful for glaucoma management.<\/jats:p>","DOI":"10.21203\/rs.3.rs-3002468\/v1","type":"posted-content","created":{"date-parts":[[2023,6,6]],"date-time":"2023-06-06T21:43:45Z","timestamp":1686087825000},"source":"Crossref","is-referenced-by-count":0,"title":["Agreement and Precision of Wide and Cube Scan Measurements between Swept-source and Spectral-domain OCT in Normal and Glaucoma Eyes"],"prefix":"10.21203","author":[{"given":"Huiyuan","family":"Hou","sequence":"first","affiliation":[{"name":"Topcon Healthcare"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nevin W.","family":"EI-Nimri","sequence":"additional","affiliation":[{"name":"Topcon Healthcare"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary K.","family":"Durbin","sequence":"additional","affiliation":[{"name":"Topcon Healthcare"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan D.","family":"Arias","sequence":"additional","affiliation":[{"name":"Topcon Healthcare"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sasan","family":"Moghimi","sequence":"additional","affiliation":[{"name":"Shiley Eye Institute, University of California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert N.","family":"Weinreb","sequence":"additional","affiliation":[{"name":"Shiley Eye Institute, University of California"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"8761","reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1001\/jama.2014.3192","article-title":"The Pathophysiology and Treatment of Glaucoma: A Review","volume":"311","author":"Weinreb RN","year":"2014","unstructured":"Weinreb, R. N., Aung, T. & Medeiros, F. A. The Pathophysiology and Treatment of Glaucoma: A Review. JAMA 311, 1901 (2014).","journal-title":"JAMA"},{"key":"ref2","unstructured":"Detecting glaucoma with only OCT: Implications for the clinic, research, screening, and AI development. (2022)."},{"key":"ref3","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1002\/cne.903000103","article-title":"Topography of ganglion cells in human retina","volume":"300","author":"Curcio CA","year":"1990","unstructured":"Curcio, C. A. & Allen, K. A. Topography of ganglion cells in human retina. J. Comp. Neurol. 300, 5\u201325 (1990).","journal-title":"J. Comp. Neurol."},{"key":"ref4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.preteyeres.2012.08.003","article-title":"Glaucomatous damage of the macula","volume":"32","author":"Hood DC","year":"2013","unstructured":"Hood, D. C., Raza, A. S., de Moraes, C. G. V., Liebmann, J. M. & Ritch, R. Glaucomatous damage of the macula. Progress in Retinal and Eye Research 32, 1\u201321 (2013).","journal-title":"Progress in Retinal and Eye Research"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1001\/jamaophthalmol.2013.7656","article-title":"Prevalence and Nature of Early Glaucomatous Defects in the Central 10\u00b0 of the Visual Field","volume":"132","author":"Traynis I","year":"2014","unstructured":"Traynis, I. et al. Prevalence and Nature of Early Glaucomatous Defects in the Central 10\u00b0 of the Visual Field. JAMA Ophthalmol 132, 291 (2014).","journal-title":"JAMA Ophthalmol"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1038\/s41433-018-0104-5","article-title":"Comparison of glaucoma-diagnostic ability between wide-field swept-source OCT retinal nerve fiber layer maps and spectral-domain OCT","volume":"32","author":"Lee WJ","year":"2018","unstructured":"Lee, W. J., Oh, S., Kim, Y. K., Jeoung, J. W. & Park, K. H. Comparison of glaucoma-diagnostic ability between wide-field swept-source OCT retinal nerve fiber layer maps and spectral-domain OCT. Eye 32, 1483\u20131492 (2018).","journal-title":"Eye"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1167\/tvst.5.6.4","article-title":"A Single Wide-Field OCT Protocol Can Provide Compelling Information for the Diagnosis of Early Glaucoma","volume":"5","author":"Hood DC","year":"2016","unstructured":"Hood, D. C. et al. A Single Wide-Field OCT Protocol Can Provide Compelling Information for the Diagnosis of Early Glaucoma. Trans. Vis. Sci. Tech. 5, 4 (2016).","journal-title":"Trans. Vis. Sci. Tech."},{"key":"ref8","doi-asserted-by":"crossref","first-page":"e0195040","DOI":"10.1371\/journal.pone.0195040","article-title":"Wide scan imaging with swept-source optical coherent tomography for glaucoma diagnosis","volume":"13","author":"Hong EH","year":"2018","unstructured":"Hong, E. H., Shin, Y. U., Kang, M. H., Cho, H. & Seong, M. Wide scan imaging with swept-source optical coherent tomography for glaucoma diagnosis. PLoS ONE 13, e0195040 (2018).","journal-title":"PLoS ONE"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"6536","DOI":"10.1167\/iovs.14-15072","article-title":"Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices","volume":"55","author":"Matlach J","year":"2014","unstructured":"Matlach, J., Wagner, M., Malzahn, U. & G\u00f6bel, W. Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices. Invest. Ophthalmol. Vis. Sci. 55, 6536 (2014).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref10","doi-asserted-by":"crossref","first-page":"e0129005","DOI":"10.1371\/journal.pone.0129005","article-title":"Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software","volume":"10","author":"Ctori I","year":"2015","unstructured":"Ctori, I. & Huntjens, B. Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software. PLoS ONE 10, e0129005 (2015).","journal-title":"PLoS ONE"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"209","DOI":"10.3928\/15428877-20110224-02","article-title":"Repeatability of Optic Nerve Head Parameters Measured by Spectral-Domain OCT in Healthy Eyes","volume":"42","author":"Savini G","year":"2011","unstructured":"Savini, G., Carbonelli, M., Parisi, V. & Barboni, P. Repeatability of Optic Nerve Head Parameters Measured by Spectral-Domain OCT in Healthy Eyes. Ophthalmic Surg Lasers Imaging 42, 209\u2013215 (2011).","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"e0149138","DOI":"10.1371\/journal.pone.0149138","article-title":"Repeatability Using Automatic Tracing with Canon OCT- HS100 and Zeiss Cirrus HD-OCT 5000","volume":"11","author":"Brautaset R","year":"2016","unstructured":"Brautaset, R., Birkeldh, U., Frehr Alstig, P., Wik\u00e9n, P. & Nilsson, M. Repeatability Using Automatic Tracing with Canon OCT- HS100 and Zeiss Cirrus HD-OCT 5000. PLoS ONE 11, e0149138 (2016).","journal-title":"PLoS ONE"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s12911-020-01370-0","article-title":"An innovative strategy for standardized, structured, and interoperable results in ophthalmic examinations","volume":"21","author":"Mun Y","year":"2021","unstructured":"Mun, Y. et al. An innovative strategy for standardized, structured, and interoperable results in ophthalmic examinations. BMC Med Inform Decis Mak 21, 9 (2021).","journal-title":"BMC Med Inform Decis Mak"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1097\/ICU.0000000000000024","article-title":"Diagnosing glaucoma progression with optical coherence tomography","volume":"25","author":"Leung C K-S","year":"2014","unstructured":"Leung, C. K.-S. Diagnosing glaucoma progression with optical coherence tomography: Current Opinion in Ophthalmology 25, 104\u2013111 (2014).","journal-title":"Current Opinion in Ophthalmology"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"764236","DOI":"10.3389\/fmed.2021.764236","article-title":"Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography","volume":"8","author":"Dom\u00ednguez-Vicent A","year":"2021","unstructured":"Dom\u00ednguez-Vicent, A., Kens\u00e9n, J., Ramsay, M. W., Brautaset, R. & Venkataraman, A. P. Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography. Front. Med. 8, 764236 (2021).","journal-title":"Front. Med."},{"key":"ref16","doi-asserted-by":"crossref","first-page":"3501","DOI":"10.1167\/iovs.14-13925","article-title":"Topographic Localization of Macular Retinal Ganglion Cell Loss Associated With Localized Peripapillary Retinal Nerve Fiber Layer Defect","volume":"55","author":"Kim KE","year":"2014","unstructured":"Kim, K. E. et al. Topographic Localization of Macular Retinal Ganglion Cell Loss Associated With Localized Peripapillary Retinal Nerve Fiber Layer Defect. Invest. Ophthalmol. Vis. Sci. 55, 3501 (2014).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref17","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1097\/IJG.0000000000000662","article-title":"Diagnostic Ability of Wide-field Retinal Nerve Fiber Layer Maps Using Swept-Source Optical Coherence Tomography for Detection of Preperimetric and Early Perimetric Glaucoma","volume":"26","author":"Lee WJ","year":"2017","unstructured":"Lee, W. J., Na, K. I., Kim, Y. K., Jeoung, J. W. & Park, K. H. Diagnostic Ability of Wide-field Retinal Nerve Fiber Layer Maps Using Swept-Source Optical Coherence Tomography for Detection of Preperimetric and Early Perimetric Glaucoma. J Glaucoma 26, 577\u2013585 (2017).","journal-title":"J Glaucoma"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.ajo.2014.10.019","article-title":"Diagnostic Ability of Retinal Nerve Fiber Layer Imaging by Swept-Source Optical Coherence Tomography in Glaucoma","volume":"159","author":"Yang Z","year":"2015","unstructured":"Yang, Z. et al. Diagnostic Ability of Retinal Nerve Fiber Layer Imaging by Swept-Source Optical Coherence Tomography in Glaucoma. American Journal of Ophthalmology 159, 193\u2013201 (2015).","journal-title":"American Journal of Ophthalmology"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"e0125957","DOI":"10.1371\/journal.pone.0125957","article-title":"Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography","volume":"10","author":"Yang Z","year":"2015","unstructured":"Yang, Z. et al. Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography. PLoS ONE 10, e0125957 (2015).","journal-title":"PLoS ONE"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10633-021-09854-8","article-title":"Monitoring for glaucoma progression with SAP, electroretinography (PERG and PhNR) and OCT","volume":"144","author":"Cvenkel B","year":"2022","unstructured":"Cvenkel, B., Sustar, M. & Perov\u0161ek, D. Monitoring for glaucoma progression with SAP, electroretinography (PERG and PhNR) and OCT. Doc Ophthalmol 144, 17\u201330 (2022).","journal-title":"Doc Ophthalmol"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"e0247670","DOI":"10.1371\/journal.pone.0247670","article-title":"Impact of optical coherence tomography scan direction on the reliability of peripapillary retinal nerve fiber layer measurements","volume":"16","author":"Venkataraman AP","year":"2021","unstructured":"Venkataraman, A. P., Andersson, J., Fivelsdal, L., Nilsson, M. & Dom\u00ednguez-Vicent, A. Impact of optical coherence tomography scan direction on the reliability of peripapillary retinal nerve fiber layer measurements. PLoS ONE 16, e0247670 (2021).","journal-title":"PLoS ONE"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"e46","DOI":"10.1097\/IJG.0000000000000536","article-title":"Repeatability and Agreement of Swept Source and Spectral Domain Optical Coherence Tomography Evaluations of Thickness Sectors in Normal Eyes","volume":"26","author":"Lee SY","year":"2017","unstructured":"Lee, S. Y., Bae, H. W., Kwon, H. J., Seong, G. J. & Kim, C. Y. Repeatability and Agreement of Swept Source and Spectral Domain Optical Coherence Tomography Evaluations of Thickness Sectors in Normal Eyes. Journal of Glaucoma 26, e46\u2013e53 (2017).","journal-title":"Journal of Glaucoma"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"849","DOI":"10.2147\/OPTH.S155229","article-title":"The development of a reference database with the Topcon 3D OCT-1 Maestro","volume":"12","author":"Chaglasian M","year":"2018","unstructured":"Chaglasian, M. et al. The development of a reference database with the Topcon 3D OCT-1 Maestro. OPTH Volume\u00a012, 849\u2013857 (2018).","journal-title":"OPTH"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"2668","DOI":"10.1167\/iovs.07-1000","article-title":"Macular Thickness Assessment in Healthy Eyes Based on Ethnicity Using Stratus OCT Optical Coherence Tomography","volume":"49","author":"Kelty PJ","year":"2008","unstructured":"Kelty, P. J. et al. Macular Thickness Assessment in Healthy Eyes Based on Ethnicity Using Stratus OCT Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 49, 2668 (2008).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref25","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1001\/archopthalmol.2011.1576","article-title":"Effect of Race, Age, and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD-OCT","volume":"130","author":"Knight OJ","year":"2012","unstructured":"Knight, O. J. Effect of Race, Age, and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD-OCT. Arch Ophthalmol 130, 312 (2012).","journal-title":"Arch Ophthalmol"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/00061198-200002000-00011","article-title":"An Optical Model of the Human Retinal Nerve Fiber Layer: Implications of Directional Reflectance for Variability of Clinical Measurements","volume":"9","author":"Knighton RW","year":"2000","unstructured":"Knighton, R. W. & Qian, C. An Optical Model of the Human Retinal Nerve Fiber Layer: Implications of Directional Reflectance for Variability of Clinical Measurements: Journal of Glaucoma 9, 56\u201362 (2000).","journal-title":"Journal of Glaucoma"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1136\/bjo.87.7.899","article-title":"Retinal thickness decreases with age: an OCT study","volume":"87","author":"Alamouti B","year":"2003","unstructured":"Alamouti, B. Retinal thickness decreases with age: an OCT study. British Journal of Ophthalmology 87, 899\u2013901 (2003).","journal-title":"British Journal of Ophthalmology"},{"key":"ref28","author":"Legend","unstructured":"Legend"}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3002468\/v1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3002468\/v1.html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,25]],"date-time":"2023-09-25T15:09:59Z","timestamp":1695654599000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3002468\/v1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,6]]},"references-count":28,"URL":"https:\/\/doi.org\/10.21203\/rs.3.rs-3002468\/v1","relation":{"is-preprint-of":[{"id-type":"doi","id":"10.1038\/s41598-023-43230-7","asserted-by":"subject"}]},"subject":[],"published":{"date-parts":[[2023,6,6]]},"subtype":"preprint"}}