{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"Research Square"}],"indexed":{"date-parts":[[2024,3,3]],"date-time":"2024-03-03T13:38:30Z","timestamp":1709473110822},"posted":{"date-parts":[[2023,7,17]]},"group-title":"In Review","reference-count":41,"publisher":"Research Square Platform LLC","license":[{"start":{"date-parts":[[2023,7,17]],"date-time":"2023-07-17T00:00:00Z","timestamp":1689552000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2023,7,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>In this work, stenting in non-calcified and heavily calcified coronary arteries was quantified in terms of diameter-pressure relationships and load transfer from the balloon to the artery. The efficacy of post-dilation in non-calcified and heavily calcified coronary arteries was also characterized in terms of load sharing and the changes in tissue mechanics. Our results have shown that stent expansion exhibits a cylindrical shape in non-calcified lesions, while it exhibits a dog bone shape in heavily calcified lesions. Load-sharing analysis has shown that only a small portion of the pressure load (1.4 N,  0.8% of total pressure load) was transferred to the non-calcified lesion, while a large amount of the pressure load (19 N, 12%) was transferred to the heavily calcified lesion. In addition, the increasing inflation pressure (from 10 to 20 atm) can effectively increase the minimal lumen diameter (from 1.48 mm to 2.82 mm) of the heavily calcified lesion, the stress (from 1.5 MPa to 8.4 MPa) the strain energy in the calcification (1.77 mJ to 26.5 mJ), which associated with the potential of calcification fracture. Results indicated that increasing inflation pressure can be an effective way to improve the stent expansion if a dog bone shape of the stenting profile is observed. Considering the risk of a balloon burst, our results support the design and application of the high-pressure balloon for post-dilation.<\/jats:p>","DOI":"10.21203\/rs.3.rs-3147116\/v1","type":"posted-content","created":{"date-parts":[[2023,7,17]],"date-time":"2023-07-17T13:51:45Z","timestamp":1689601905000},"source":"Crossref","is-referenced-by-count":0,"title":["Load-sharing characteristics of stenting and post-dilation in heavily calcified coronary artery"],"prefix":"10.21203","author":[{"given":"Pengfei","family":"Dong","sequence":"first","affiliation":[{"name":"Florida Institute of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jose","family":"Colmenarez","sequence":"additional","affiliation":[{"name":"Florida Institute of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juhwan","family":"Lee","sequence":"additional","affiliation":[{"name":"Case Western Reserve University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neda Shafiabadi","family":"Hassani","sequence":"additional","affiliation":[{"name":"University Hospitals Cleveland Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David L.","family":"Wilson","sequence":"additional","affiliation":[{"name":"Case Western Reserve University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiram G.","family":"Bezerra","sequence":"additional","affiliation":[{"name":"The University of South Florida"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linxia","family":"Gu","sequence":"additional","affiliation":[{"name":"Florida Institute of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"8761","reference":[{"issue":"2","key":"ref1","doi-asserted-by":"crossref","first-page":"81","DOI":"10.15420\/icr.2017:12:1","article-title":"Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-Compliant Balloons","volume":"12","author":"Seth A","year":"2017","unstructured":"Seth, A., Gupta, S., Pratap Singh, V., and Kumar, V., 2017, \u201cExpert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-Compliant Balloons,\u201d Interv Cardiol, 12(2), pp.\u00a081\u201384.","journal-title":"Interv Cardiol"},{"issue":"5","key":"ref2","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1016\/j.ahj.2010.07.007","article-title":"Differential Effects of Post-Dilation after Stent Deployment in Patients Presenting with and without Acute Myocardial Infarction","volume":"160","author":"Zhang Z-J","year":"2010","unstructured":"Zhang, Z.-J., Marroquin, O. C., Stone, R. A., Weissfeld, J. L., Mulukutla, S. R., Selzer, F., and Kip, K. E., 2010, \u201cDifferential Effects of Post-Dilation after Stent Deployment in Patients Presenting with and without Acute Myocardial Infarction,\u201d Am Heart J, 160(5), pp.\u00a0979\u2013986.e1.","journal-title":"Am Heart J"},{"issue":"5","key":"ref3","first-page":"635","article-title":"Extremely High-Pressure Dilation with a New Noncompliant Balloon","volume":"39","author":"D\u00edaz JF","year":"2012","unstructured":"D\u00edaz, J. F., G\u00f3mez-Menchero, A., Cardenal, R., S\u00e1nchez-Gonz\u00e1lez, C., and Sanghvi, A., 2012, \u201cExtremely High-Pressure Dilation with a New Noncompliant Balloon,\u201d Tex Heart Inst J, 39(5), pp.\u00a0635\u2013638.","journal-title":"Tex Heart Inst J"},{"issue":"17","key":"ref4","doi-asserted-by":"crossref","first-page":"2110","DOI":"10.4244\/EIJ-D-16-00974","article-title":"\u201cPredilation, Sizing and Post-Dilation Scoring in Patients Undergoing Everolimus-Eluting Bioresorbable Scaffold Implantation for Prediction of Cardiac Adverse Events: Development and Internal Validation of the PSP Score","volume":"12","author":"Ortega-Paz L","year":"2017","unstructured":"Ortega-Paz, L., Capodanno, D., Gori, T., Nef, H., Latib, A., Caramanno, G., Di Mario, C., Naber, C., Lesiak, M., Capranzano, P., Wiebe, J., Mehilli, J., Araszkiewicz, A., Pyxaras, S., Mattesini, A., Geraci, S., Naganuma, T., Colombo, A., M\u00fcnzel, T., Sabat\u00e9, M., Tamburino, C., and Brugaletta, S., 2017, \u201cPredilation, Sizing and Post-Dilation Scoring in Patients Undergoing Everolimus-Eluting Bioresorbable Scaffold Implantation for Prediction of Cardiac Adverse Events: Development and Internal Validation of the PSP Score,\u201d EuroIntervention, 12(17), pp.\u00a02110\u20132117.","journal-title":"EuroIntervention"},{"issue":"11","key":"ref5","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1016\/S0002-9149(02)02832-1","article-title":"Direct Coronary Stenting versus Predilatation Followed by Stent Placement","volume":"90","author":"Brueck M","year":"2002","unstructured":"Brueck, M., Scheinert, D., Wortmann, A., Bremer, J., Korn, H. von, Klinghammer, L., Kramer, W., Flachskampf, F. A., Daniel, W. G., and Ludwig, J., 2002, \u201cDirect Coronary Stenting versus Predilatation Followed by Stent Placement,\u201d American Journal of Cardiology, 90(11), pp.\u00a01187\u20131192.","journal-title":"American Journal of Cardiology"},{"issue":"5","key":"ref6","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1536\/ihj.49.545","article-title":"Direct Stenting versus Predilatation and Stenting Technique When Using Paclitaxel-Eluting Stents","volume":"49","author":"Kocum T","year":"2008","unstructured":"Kocum, T., Yurtdas, M., Ozcan, T., Akcay, B., Erol, T., Camsari, A., and Doven, O., 2008, \u201cDirect Stenting versus Predilatation and Stenting Technique When Using Paclitaxel-Eluting Stents,\u201d Int Heart J, 49(5), pp.\u00a0545\u2013552.","journal-title":"Int Heart J"},{"issue":"5","key":"ref7","doi-asserted-by":"crossref","first-page":"E9","DOI":"10.1067\/mhj.2001.119124","article-title":"\u201cA Randomized Trial of Stenting with or without Balloon Predilation for the Treatment of Coronary Artery Disease","volume":"142","author":"Kovar LI","year":"2001","unstructured":"Kovar, L. I., Monrad, E. S., Sherman, W., Kunchithapatham, S., Ravi, K. L., Gotsis, W., Silverman, G., and Brown, D. L., 2001, \u201cA Randomized Trial of Stenting with or without Balloon Predilation for the Treatment of Coronary Artery Disease,\u201d Am Heart J, 142(5), p.\u00a0E9.","journal-title":"Am Heart J"},{"issue":"4","key":"ref8","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s12928-020-00643-9","article-title":"Effects of High-Speed Rotational Atherectomy in Peripheral Artery Disease Patients with Calcified Lesions: A Retrospective Multicenter Registry","volume":"35","author":"Yamamoto Y","year":"2020","unstructured":"Yamamoto, Y., Kawarada, O., Ando, H., Anzai, H., Zen, K., Tamura, K., Tsukahara, K., Tsubakimoto, Y., Toma, M., Nakamura, S., Nakamura, H., Hozawa, K., Yokoi, Y., and Yasuda, S., 2020, \u201cEffects of High-Speed Rotational Atherectomy in Peripheral Artery Disease Patients with Calcified Lesions: A Retrospective Multicenter Registry,\u201d Cardiovasc Interv and Ther, 35(4), pp.\u00a0393\u2013397.","journal-title":"Cardiovasc Interv and Ther"},{"issue":"4","key":"ref9","first-page":"213","article-title":"Long-Term Safety and Performance of the Orbital Atherectomy System for Treating Calcified Coronary Artery Lesions: 5-Year Follow-up in the ORBIT I Trial","volume":"16","author":"2015","unstructured":"2015, \u201cLong-Term Safety and Performance of the Orbital Atherectomy System for Treating Calcified Coronary Artery Lesions: 5-Year Follow-up in the ORBIT I Trial,\u201d Cardiovascular Revascularization Medicine, 16(4), pp.\u00a0213\u2013216.","journal-title":"Cardiovascular Revascularization Medicine"},{"issue":"1","key":"ref10","doi-asserted-by":"crossref","first-page":"33","DOI":"10.15420\/icr.2015:19:2","article-title":"Patient Selection and Procedural Considerations for Coronary Orbital Atherectomy System","volume":"11","author":"Sotomi Y","year":"2016","unstructured":"Sotomi, Y., Shlofmitz, R. A., Colombo, A., Serruys, P. W., and Onuma, Y., 2016, \u201cPatient Selection and Procedural Considerations for Coronary Orbital Atherectomy System,\u201d Interv Cardiol, 11(1), pp.\u00a033\u201338.","journal-title":"Interv Cardiol"},{"issue":"5","key":"ref11","first-page":"510","article-title":"Pivotal Trial to Evaluate the Safety and Efficacy of the Orbital Atherectomy System in Treating De Novo, Severely Calcified Coronary Lesions (ORBIT II)","volume":"7","author":"Chambers Jeffrey W","year":"2014","unstructured":"Chambers Jeffrey W., Feldman Robert L., Himmelstein Stevan I., Bhatheja Rohit, Villa Augusto E., Strickman Neil E., Shlofmitz Richard A., Dulas Daniel D., Arab Dinesh, Khanna Puneet K., Lee Arthur C., Ghali Magdi G.H., Shah Rakesh R., Davis Thomas P., Kim Christopher Y., Tai Zaheed, Patel Kirit C., Puma Joseph A., Makam Prakash, Bertolet Barry D., and Nseir Georges Y., 2014, \u201cPivotal Trial to Evaluate the Safety and Efficacy of the Orbital Atherectomy System in Treating De Novo, Severely Calcified Coronary Lesions (ORBIT II),\u201d JACC: Cardiovascular Interventions, 7(5), pp.\u00a0510\u2013518.","journal-title":"JACC: Cardiovascular Interventions"},{"issue":"1","key":"ref12","doi-asserted-by":"crossref","first-page":"e3282","DOI":"10.1002\/cnm.3282","article-title":"\u201cA New Finite-Element Shell Model for Arterial Growth and Remodeling after Stent Implantation","volume":"36","author":"Laubrie JD","year":"2020","unstructured":"Laubrie, J. D., Mousavi, J. S., and Avril, S., 2020, \u201cA New Finite-Element Shell Model for Arterial Growth and Remodeling after Stent Implantation,\u201d International Journal for Numerical Methods in Biomedical Engineering, 36(1), p.\u00a0e3282.","journal-title":"International Journal for Numerical Methods in Biomedical Engineering"},{"issue":"1","key":"ref13","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1515\/ntrev-2020-0056","article-title":"Braided Composite Stent for Peripheral Vascular Applications","volume":"9","author":"Zheng Q","year":"2020","unstructured":"Zheng, Q., Dong, P., Li, Z., Lv, Y., An, M., and Gu, L., 2020, \u201cBraided Composite Stent for Peripheral Vascular Applications,\u201d Nanotechnology Reviews, 9(1), pp.\u00a01137\u20131146.","journal-title":"Nanotechnology Reviews"},{"issue":"1","key":"ref14","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1515\/ntrev-2020-0093","article-title":"Degradation Modeling of Poly-l-Lactide Acid (PLLA) Bioresorbable Vascular Scaffold within a Coronary Artery","volume":"9","author":"Lin S","year":"2020","unstructured":"Lin, S., Dong, P., Zhou, C., Dallan, L. A. P., Zimin, V. N., Pereira, G. T. R., Lee, J., Gharaibeh, Y., Wilson, D. L., Bezerra, H. G., and Gu, L., 2020, \u201cDegradation Modeling of Poly-l-Lactide Acid (PLLA) Bioresorbable Vascular Scaffold within a Coronary Artery,\u201d Nanotechnology Reviews, 9(1), pp.\u00a01217\u20131226.","journal-title":"Nanotechnology Reviews"},{"issue":"15","key":"ref15","doi-asserted-by":"crossref","first-page":"2140","DOI":"10.1177\/1045389X16685442","article-title":"Finite Element Simulation and Optimization of Radial Resistive Force for Shape Memory Alloy Vertebral Body Stent","volume":"28","author":"Wang R","year":"2017","unstructured":"Wang, R., Zuo, H., Yang, Y.-M., Yang, B., and Li, Q., 2017, \u201cFinite Element Simulation and Optimization of Radial Resistive Force for Shape Memory Alloy Vertebral Body Stent,\u201d Journal of Intelligent Material Systems and Structures, 28(15), pp.\u00a02140\u20132150.","journal-title":"Journal of Intelligent Material Systems and Structures"},{"issue":"1","key":"ref16","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1515\/ntrev-2019-0016","article-title":"Mechanical Characterizations of Braided Composite Stents Made of Helical Polyethylene Terephthalate Strips and NiTi Wires","volume":"8","author":"Zheng Q","year":"2019","unstructured":"Zheng, Q., Dong, P., Li, Z., Han, X., Zhou, C., An, M., and Gu, L., 2019, \u201cMechanical Characterizations of Braided Composite Stents Made of Helical Polyethylene Terephthalate Strips and NiTi Wires,\u201d Nanotechnology Reviews, 8(1), pp.\u00a0168\u2013174.","journal-title":"Nanotechnology Reviews"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.compbiomed.2018.06.031","article-title":"Migration Resistance of Esophageal Stents: The Role of Stent Design","volume":"100","year":"2018","unstructured":"2018, \u201cMigration Resistance of Esophageal Stents: The Role of Stent Design,\u201d Computers in Biology and Medicine, 100, pp.\u00a043\u201349.","journal-title":"Computers in Biology and Medicine"},{"issue":"031005","key":"ref18","article-title":"The Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting","volume":"4","author":"Gu L","year":"2010","unstructured":"Gu, L., Zhao, S., Muttyam, A. K., and Hammel, J. M., 2010, \u201cThe Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting,\u201d Journal of Medical Devices, 4(031005).","journal-title":"Journal of Medical Devices"},{"issue":"8","key":"ref19","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1016\/j.jbiomech.2004.07.022","article-title":"Cardiovascular Stent Design and Vessel Stresses: A Finite Element Analysis","volume":"38","year":"2005","unstructured":"2005, \u201cCardiovascular Stent Design and Vessel Stresses: A Finite Element Analysis,\u201d Journal of Biomechanics, 38(8), pp.\u00a01574\u20131581.","journal-title":"Journal of Biomechanics"},{"issue":"1","key":"ref20","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s10237-018-1066-z","article-title":"Influences of Plaque Eccentricity and Composition on the Stent\u2013Plaque\u2013Artery Interaction during Stent Implantation","volume":"18","author":"Wei L","year":"2019","unstructured":"Wei, L., Chen, Q., and Li, Z., 2019, \u201cInfluences of Plaque Eccentricity and Composition on the Stent\u2013Plaque\u2013Artery Interaction during Stent Implantation,\u201d Biomech Model Mechanobiol, 18(1), pp.\u00a045\u201356.","journal-title":"Biomech Model Mechanobiol"},{"issue":"9","key":"ref21","doi-asserted-by":"crossref","first-page":"2244","DOI":"10.1007\/s10439-017-1851-3","article-title":"Numerical Simulation of Stent Angioplasty with Predilation: An Investigation into Lesion Constitutive Representation and Calcification Influence","volume":"45","author":"Conway C","year":"2017","unstructured":"Conway, C., McGarry, J. P., Edelman, E. R., and McHugh, P. E., 2017, \u201cNumerical Simulation of Stent Angioplasty with Predilation: An Investigation into Lesion Constitutive Representation and Calcification Influence,\u201d Ann Biomed Eng, 45(9), pp.\u00a02244\u20132252.","journal-title":"Ann Biomed Eng"},{"issue":"021010","key":"ref22","article-title":"Impact of Calcium Quantifications on Stent Expansions","volume":"141","author":"Dong P","year":"2018","unstructured":"Dong, P., Bezerra, H. G., Wilson, D. L., and Gu, L., 2018, \u201cImpact of Calcium Quantifications on Stent Expansions,\u201d Journal of Biomechanical Engineering, 141(021010).","journal-title":"Journal of Biomechanical Engineering"},{"issue":"051012","key":"ref23","article-title":"\u201cOptical Coherence Tomography-Based Modeling of Stent Deployment in Heavily Calcified Coronary Lesion","volume":"142","author":"Dong P","year":"2020","unstructured":"Dong, P., Mozafari, H., Prabhu, D., Bezerra, H. G., Wilson, D. L., and Gu, L., 2020, \u201cOptical Coherence Tomography-Based Modeling of Stent Deployment in Heavily Calcified Coronary Lesion,\u201d Journal of Biomechanical Engineering, 142(051012).","journal-title":"Journal of Biomechanical Engineering"},{"issue":"17","key":"ref24","doi-asserted-by":"crossref","first-page":"5820","DOI":"10.3390\/app10175820","article-title":"Simulation-Driven Machine Learning for Predicting Stent Expansion in Calcified Coronary Artery","volume":"10","author":"Dong P","year":"2020","unstructured":"Dong, P., Ye, G., Kaya, M., and Gu, L., 2020, \u201cSimulation-Driven Machine Learning for Predicting Stent Expansion in Calcified Coronary Artery,\u201d Applied Sciences, 10(17), p.\u00a05820.","journal-title":"Applied Sciences"},{"issue":"4","key":"ref25","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.ejvs.2017.07.022","article-title":"Calcification Volume Reduces Stretch Capability and Predisposes Plaque to Rupture in an in Vitro Model of Carotid Artery Stenting","volume":"54","author":"Barrett HE","year":"2017","unstructured":"Barrett, H. E., Cunnane, E. M., Hidayat, H., O Brien, J. M., Kavanagh, E. G., and Walsh, M. T., 2017, \u201cCalcification Volume Reduces Stretch Capability and Predisposes Plaque to Rupture in an in Vitro Model of Carotid Artery Stenting,\u201d Eur J Vasc Endovasc Surg, 54(4), pp.\u00a0431\u2013438.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"104609","DOI":"10.1016\/j.jmbbm.2021.104609","article-title":"Mechanical Performances of Balloon Post-Dilation for Improving Stent Expansion in Calcified Coronary Artery: Computational and Experimental Investigations","volume":"121","author":"Dong P","year":"2021","unstructured":"Dong, P., Mozafari, H., Lee, J., Gharaibeh, Y., Zimin, V. N., Dallan, L. A. P., Bezerra, H. G., Wilson, D. L., and Gu, L., 2021, \u201cMechanical Performances of Balloon Post-Dilation for Improving Stent Expansion in Calcified Coronary Artery: Computational and Experimental Investigations,\u201d Journal of the Mechanical Behavior of Biomedical Materials, 121, p.\u00a0104609.","journal-title":"Journal of the Mechanical Behavior of Biomedical Materials"},{"issue":"1","key":"ref27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40759-014-0002-x","article-title":"\u201cA Study of Balloon Type, System Constraint and Artery Constitutive Model Used in Finite Element Simulation of Stent Deployment","volume":"1","author":"Schiavone A","year":"2015","unstructured":"Schiavone, A., and Zhao, L. G., 2015, \u201cA Study of Balloon Type, System Constraint and Artery Constitutive Model Used in Finite Element Simulation of Stent Deployment,\u201d Mechanics of Advanced Materials and Modern Processes, 1(1), p.\u00a01.","journal-title":"Mechanics of Advanced Materials and Modern Processes"},{"issue":"6","key":"ref28","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1016\/j.jbiomech.2008.01.027","article-title":"On the Effects of Different Strategies in Modelling Balloon-Expandable Stenting by Means of Finite Element Method","volume":"41","author":"Gervaso F","year":"2008","unstructured":"Gervaso, F., Capelli, C., Petrini, L., Lattanzio, S., Di Virgilio, L., and Migliavacca, F., 2008, \u201cOn the Effects of Different Strategies in Modelling Balloon-Expandable Stenting by Means of Finite Element Method,\u201d J Biomech, 41(6), pp.\u00a01206\u20131212.","journal-title":"J Biomech"},{"issue":"2","key":"ref29","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.jbiomech.2007.08.014","article-title":"\u201cRealistic Finite Element-Based Stent Design: The Impact of Balloon Folding","volume":"41","author":"Beule M","year":"2008","unstructured":"De Beule, M., Mortier, P., Carlier, S. G., Verhegghe, B., Van Impe, R., and Verdonck, P., 2008, \u201cRealistic Finite Element-Based Stent Design: The Impact of Balloon Folding,\u201d J Biomech, 41(2), pp.\u00a0383\u2013389.","journal-title":"J Biomech"},{"issue":"11","key":"ref30","doi-asserted-by":"crossref","first-page":"2102","DOI":"10.1016\/j.jbiomech.2015.11.024","article-title":"Computational Replication of the Patient-Specific Stenting Procedure for Coronary Artery Bifurcations: From OCT and CT Imaging to Structural and Hemodynamics Analyses","volume":"49","year":"2016","unstructured":"2016, \u201cComputational Replication of the Patient-Specific Stenting Procedure for Coronary Artery Bifurcations: From OCT and CT Imaging to Structural and Hemodynamics Analyses,\u201d Journal of Biomechanics, 49(11), pp.\u00a02102\u20132111.","journal-title":"Journal of Biomechanics"},{"key":"ref31","author":"Martin D","year":"2013","unstructured":"Martin, D., and Boyle, F., 2013, \u201cFinite Element Analysis of Balloon-Expandable Coronary Stent Deployment: Influence of Angioplasty Balloon Configuration: FINITE ELEMENT ANALYSIS OF CORONARY STENT DEPLOYMENT,\u201d Int. J. Numer. Meth. Biomed. Engng., 29(11), pp.\u00a01161\u20131175."},{"issue":"021001","key":"ref32","article-title":"Finite Element Analysis of the Implantation of a Self-Expanding Stent: Impact of Lesion Calcification","volume":"6","author":"Zhao S","year":"2012","unstructured":"Zhao, S., Gu, L., and Froemming, S. R., 2012, \u201cFinite Element Analysis of the Implantation of a Self-Expanding Stent: Impact of Lesion Calcification,\u201d Journal of Medical Devices, 6(021001).","journal-title":"Journal of Medical Devices"},{"issue":"3","key":"ref33","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.ijcard.2004.12.033","article-title":"Finite Element Analysis of the Implantation of a Balloon-Expandable Stent in a Stenosed Artery","volume":"104","author":"Liang DK","year":"2005","unstructured":"Liang, D. K., Yang, D. Z., Qi, M., and Wang, W. Q., 2005, \u201cFinite Element Analysis of the Implantation of a Balloon-Expandable Stent in a Stenosed Artery,\u201d International Journal of Cardiology, 104(3), pp.\u00a0314\u2013318.","journal-title":"International Journal of Cardiology"},{"issue":"5","key":"ref34","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1007\/s10237-010-0196-8","article-title":"Modelling of the Provisional Side-Branch Stenting Approach for the Treatment of Atherosclerotic Coronary Bifurcations: Effects of Stent Positioning","volume":"9","author":"Gastaldi D","year":"2010","unstructured":"Gastaldi, D., Morlacchi, S., Nichetti, R., Capelli, C., Dubini, G., Petrini, L., and Migliavacca, F., 2010, \u201cModelling of the Provisional Side-Branch Stenting Approach for the Treatment of Atherosclerotic Coronary Bifurcations: Effects of Stent Positioning,\u201d Biomech Model Mechanobiol, 9(5), pp.\u00a0551\u2013561.","journal-title":"Biomech Model Mechanobiol"},{"issue":"4","key":"ref35","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.medengphy.2008.11.005","article-title":"The Influence of Plaque Composition on Underlying Arterial Wall Stress during Stent Expansion: The Case for Lesion-Specific Stents","volume":"31","author":"Pericevic I","year":"2009","unstructured":"Pericevic, I., Lally, C., Toner, D., and Kelly, D. J., 2009, \u201cThe Influence of Plaque Composition on Underlying Arterial Wall Stress during Stent Expansion: The Case for Lesion-Specific Stents,\u201d Medical Engineering & Physics, 31(4), pp.\u00a0428\u2013433.","journal-title":"Medical Engineering & Physics"},{"issue":"4","key":"ref36","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1016\/j.jbiomech.2014.01.007","article-title":"Influence of Plaque Calcifications on Coronary Stent Fracture: A Numerical Fatigue Life Analysis Including Cardiac Wall Movement","volume":"47","author":"Morlacchi S","year":"2014","unstructured":"Morlacchi, S., Pennati, G., Petrini, L., Dubini, G., and Migliavacca, F., 2014, \u201cInfluence of Plaque Calcifications on Coronary Stent Fracture: A Numerical Fatigue Life Analysis Including Cardiac Wall Movement,\u201d Journal of Biomechanics, 47(4), pp.\u00a0899\u2013907.","journal-title":"Journal of Biomechanics"},{"issue":"5","key":"ref37","doi-asserted-by":"crossref","DOI":"10.1115\/1.4045285","article-title":"\u201cOptical Coherence Tomography-Based Modeling of Stent Deployment in Heavily Calcified Coronary Lesion","volume":"142","author":"Dong P","year":"2020","unstructured":"Dong, P., Mozafari, H., Prabhu, D., Bezerra, H. G., Wilson, D. L., and Gu, L., 2020, \u201cOptical Coherence Tomography-Based Modeling of Stent Deployment in Heavily Calcified Coronary Lesion,\u201d Journal of biomechanical engineering, 142(5).","journal-title":"Journal of biomechanical engineering"},{"key":"ref38","unstructured":"\u201cUnderstanding Blood Pressure Readings,\u201d www.heart.org [Online]. Available: https:\/\/www.heart.org\/en\/health-topics\/high-blood-pressure\/understanding-blood-pressure-readings. [Accessed: 24-Apr-2022]."},{"issue":"12","key":"ref39","doi-asserted-by":"crossref","first-page":"2868","DOI":"10.1007\/s10439-015-1358-8","article-title":"Nitinol Stent Oversizing in Patients Undergoing Popliteal Artery Revascularization: A Finite Element Study","volume":"43","author":"G\u00f6kg\u00f6l C","year":"2015","unstructured":"G\u00f6kg\u00f6l, C., Diehm, N., Nezami, F. R., and B\u00fcchler, P., 2015, \u201cNitinol Stent Oversizing in Patients Undergoing Popliteal Artery Revascularization: A Finite Element Study,\u201d Ann Biomed Eng, 43(12), pp.\u00a02868\u20132880.","journal-title":"Ann Biomed Eng"},{"issue":"3","key":"ref40","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1080\/10255842.2020.1822823","article-title":"Finite Element Simulation and Testing of Cobalt-Chromium Stent: A Parametric Study on Radial Strength, Recoil, Foreshortening, and Dogboning","volume":"24","author":"Kumar A","year":"2021","unstructured":"Kumar, A., and Bhatnagar, N., 2021, \u201cFinite Element Simulation and Testing of Cobalt-Chromium Stent: A Parametric Study on Radial Strength, Recoil, Foreshortening, and Dogboning,\u201d Computer Methods in Biomechanics and Biomedical Engineering, 24(3), pp.\u00a0245\u2013259.","journal-title":"Computer Methods in Biomechanics and Biomedical Engineering"},{"key":"ref41","volume-title":"\u201cTarget Lesion Calcium Arc Influence the Performance of Stenting","author":"Dong P","year":"2017","unstructured":"Dong, P., Lin, S., Wilson, D. L., Bezerra, H. G., and Gu, L., 2017, \u201cTarget Lesion Calcium Arc Influence the Performance of Stenting,\u201d American Society of Mechanical Engineers Digital Collection."}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3147116\/v1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3147116\/v1.html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T15:54:11Z","timestamp":1696866851000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3147116\/v1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,17]]},"references-count":41,"URL":"https:\/\/doi.org\/10.21203\/rs.3.rs-3147116\/v1","relation":{"is-preprint-of":[{"id-type":"doi","id":"10.1038\/s41598-023-43160-4","asserted-by":"subject"}]},"subject":[],"published":{"date-parts":[[2023,7,17]]},"subtype":"preprint"}}