{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"Research Square"}],"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T06:42:56Z","timestamp":1747204976954,"version":"3.40.5"},"posted":{"date-parts":[[2023,12,27]]},"group-title":"In Review","reference-count":41,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T00:00:00Z","timestamp":1703635200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2023,12,16]]},"abstract":"<title>Abstract<\/title>\n        <p>Purpose\n Kinetic modeling of <sup>18<\/sup>F-florbetaben provides important quantification of brain amyloid deposition in research and clinical settings but its use is limited by the requirement of arterial blood data for quantitative PET. The total-body EXPLORER PET scanner supports the dynamic acquisition of a full human body simultaneously and permits noninvasive image-derived input functions (IDIFs) as an alternative to arterial blood sampling. This study quantified brain amyloid burden with kinetic modeling, leveraging dynamic \u00b9\u2078F-florbetaben PET in aorta IDIFs and the brain in an elderly cohort.\nMethods\n \u00b9\u2078F-florbetaben dynamic PET imaging was performed on the EXPLORER system with tracer injection (300 MBq) in 3 individuals with Alzheimer's disease (AD), 3 with mild cognitive impairment, and 9 healthy controls. Image-derived input functions were extracted from the descending aorta with manual regions of interest based on the first 30 seconds after injection. Dynamic time-activity curves (TACs) for 110 minutes were fitted to the two-tissue compartment model (2TCM) using population-based metabolite corrected IDIFs to calculate total and specific distribution volumes (V<sub>T<\/sub>, V<sub>s<\/sub>) in key brain regions with early amyloid accumulation. Non-displaceable binding potential (\\({BP}_{ND})\\) was also calculated from the multi-reference tissue model (MRTM).\nResults\n Amyloid-positive (AD) patients showed the highest V<sub>T<\/sub> and V<sub>S<\/sub> in anterior cingulate, posterior cingulate, and precuneus, consistent with \\({BP}_{ND}\\) analysis. \\({BP}_{ND}\\)and V<sub>T<\/sub> from kinetic models were correlated (r\u00b2 = 0.46, P\u2009&lt;\u20092\\({e}^{-16})\\) with a stronger positive correlation observed in amyloid-positive participants, indicating reliable model fits with the IDIFs. V<sub>T<\/sub> from 2TCM was highly correlated (\\({r}^{2}\\)= 0.65, P\u2009&lt;\u20092\\({e}^{-16}\\)) with Logan graphical V<sub>T<\/sub> estimation.\nConclusion\n Non-invasive quantification of amyloid binding from total-body \u00b9\u2078F-florbetaben PET data is feasible using aorta IDIFs with high agreement between kinetic distribution volume parameters compared to \\({BP}_{ND}\\)in amyloid-positive and negative older individuals.<\/p>","DOI":"10.21203\/rs.3.rs-3764930\/v1","type":"posted-content","created":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T12:13:06Z","timestamp":1703679186000},"source":"Crossref","is-referenced-by-count":1,"title":["Non-invasive quantification of 18F-florbetaben with total-body EXPLORER PET"],"prefix":"10.21203","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-9420-9195","authenticated-orcid":false,"given":"Emily Nicole","family":"Holy","sequence":"first","affiliation":[{"name":"UC Davis: University of California Davis"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth","family":"Li","sequence":"additional","affiliation":[{"name":"University of Pennsylvania Department of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anjan","family":"Bhattarai","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Biomedical Engineering"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evan","family":"Fletcher","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Neurology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evelyn R.","family":"Alfaro","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Neurology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danielle J.","family":"Harvey","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Public Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin A.","family":"Spencer","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon R.","family":"Cherry","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles S.","family":"DeCarli","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Neurology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Audrey P.","family":"Fan","sequence":"additional","affiliation":[{"name":"University of California Davis Department of Biomedical Engineering"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"624330","DOI":"10.3389\/fnagi.2021.624330","article-title":"PET Neuroimaging of Alzheimer\u2019s Disease: Radiotracers and Their Utility in Clinical Research","volume":"13","author":"Bao W","year":"2021","unstructured":"Bao W, Xie F, Zuo C, Guan Y, Huang YH. PET Neuroimaging of Alzheimer\u2019s Disease: Radiotracers and Their Utility in Clinical Research. Front Aging Neurosci. 2021;13:624330. 10.3389\/fnagi.2021.624330.","journal-title":"Front Aging Neurosci"},{"issue":"3","key":"ref2","doi-asserted-by":"publisher","first-page":"393","DOI":"10.14283\/jpad.2022.48","article-title":"The Future of AD Clinical Trials with the Advent of Anti-Amyloid Therapies: An CTAD Task Force Report","volume":"9","author":"Delrieu J","year":"2022","unstructured":"Delrieu J, Bateman RJ, Touchon J, Sabbagh M, Cummings J. The Future of AD Clinical Trials with the Advent of Anti-Amyloid Therapies: An CTAD Task Force Report. J Prev Alzheimers Dis. 2022;9(3):393\u20139. 10.14283\/jpad.2022.48.","journal-title":"J Prev Alzheimers Dis"},{"issue":"10","key":"ref3","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1007\/s12149-016-1115-6","article-title":"Automated quantification of amyloid positron emission tomography: a comparison of PMOD and MIMneuro","volume":"30","author":"Choi WH","year":"2016","unstructured":"Choi WH, Um YH, Jung WS, Kim SH. Automated quantification of amyloid positron emission tomography: a comparison of PMOD and MIMneuro. Ann Nucl Med. 2016;30(10):682\u20139. 10.1007\/s12149-016-1115-6.","journal-title":"Ann Nucl Med"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.nicl.2017.04.025","article-title":"Optimized classification of 18F-Florbetaben PET scans as positive and negative using an SUVR quantitative approach and comparison to visual assessment","volume":"15","author":"Bullich S","year":"2017","unstructured":"Bullich S, Seibyl J, Catafau AM, et al. Optimized classification of 18F-Florbetaben PET scans as positive and negative using an SUVR quantitative approach and comparison to visual assessment. NeuroImage Clin. 2017;15:325\u201332. 10.1016\/j.nicl.2017.04.025.","journal-title":"NeuroImage Clin"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"117953","DOI":"10.1016\/j.neuroimage.2021.117953","article-title":"Parametric imaging of dual-time window [18F]flutemetamol and [18F]florbetaben studies","volume":"234","author":"Heeman F","year":"2021","unstructured":"Heeman F, Yaqub M, Hendriks J, et al. Parametric imaging of dual-time window [18F]flutemetamol and [18F]florbetaben studies. NeuroImage. 2021;234:117953. 10.1016\/j.neuroimage.2021.117953.","journal-title":"NeuroImage"},{"issue":"1","key":"ref6","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13550-019-0499-4","article-title":"Optimized dual-time-window protocols for quantitative [18F]flutemetamol and [18F]florbetaben PET studies","volume":"9","author":"Heeman F","year":"2019","unstructured":"Heeman F, Yaqub M, Lopes Alves I, et al. Optimized dual-time-window protocols for quantitative [18F]flutemetamol and [18F]florbetaben PET studies. EJNMMI Res. 2019;9(1):32. 10.1186\/s13550-019-0499-4.","journal-title":"EJNMMI Res"},{"issue":"9","key":"ref7","doi-asserted-by":"publisher","first-page":"1533","DOI":"10.1038\/sj.jcbfm.9600493","article-title":"Consensus nomenclature for in vivo imaging of reversibly binding radioligands","volume":"27","author":"Innis RB","year":"2007","unstructured":"Innis RB, Cunningham VJ, Delforge J, et al. Consensus nomenclature for in vivo imaging of reversibly binding radioligands. J Cereb Blood Flow Metab Off J Int Soc Cereb Blood Flow Metab. 2007;27(9):1533\u20139. 10.1038\/sj.jcbfm.9600493.","journal-title":"J Cereb Blood Flow Metab Off J Int Soc Cereb Blood Flow Metab"},{"issue":"3","key":"ref8","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1177\/0271678X20918029","article-title":"Simulating the effect of cerebral blood flow changes on regional quantification of [18F]flutemetamol and [18F]florbetaben studies","volume":"41","author":"Heeman F","year":"2021","unstructured":"Heeman F, Yaqub M, Lopes Alves I, et al. Simulating the effect of cerebral blood flow changes on regional quantification of [18F]flutemetamol and [18F]florbetaben studies. J Cereb Blood Flow Metab. 2021;41(3):579\u201389. 10.1177\/0271678X20918029.","journal-title":"J Cereb Blood Flow Metab"},{"author":"Morris ED","key":"ref9","unstructured":"Morris ED, Endres CJ, Schmidt KC, Christian BT Jr, Fisher RFM. RE. Kinetic Modeling in Positron Emission Tomography."},{"key":"ref10","volume-title":"Introduction to Modeling in Physiology and Medicine","author":"Cobeli CC","year":"2019","unstructured":"Cobeli CC. Introduction to Modeling in Physiology and Medicine. 2nd ed. London: Elsevier\/Academic Press; 2019.","edition":"2"},{"issue":"381","key":"ref11","doi-asserted-by":"publisher","first-page":"eaaf6169","DOI":"10.1126\/scitranslmed.aaf6169","article-title":"Total-body imaging: Transforming the role of positron emission tomography","volume":"9","author":"Cherry SR","year":"2017","unstructured":"Cherry SR, Badawi RD, Karp JS, Moses WW, Price P, Jones T. Total-body imaging: Transforming the role of positron emission tomography. Sci Transl Med. 2017;9(381):eaaf6169. 10.1126\/scitranslmed.aaf6169.","journal-title":"Sci Transl Med"},{"issue":"6","key":"ref12","doi-asserted-by":"publisher","first-page":"861","DOI":"10.2967\/jnumed.120.250597","article-title":"Performance Evaluation of the uEXPLORER Total-Body PET\/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View","volume":"62","author":"Spencer BA","year":"2021","unstructured":"Spencer BA, Berg E, Schmall JP, et al. Performance Evaluation of the uEXPLORER Total-Body PET\/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View. J Nucl Med Off Publ Soc Nucl Med. 2021;62(6):861\u201370. 10.2967\/jnumed.120.250597.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"issue":"10","key":"ref13","doi-asserted-by":"publisher","first-page":"1986","DOI":"10.1038\/jcbfm.2011.107","article-title":"Image-derived input function for brain PET studies: many challenges and few opportunities","volume":"31","author":"Zanotti-Fregonara P","year":"2011","unstructured":"Zanotti-Fregonara P, Chen K, Liow JS, Fujita M, Innis RB. Image-derived input function for brain PET studies: many challenges and few opportunities. J Cereb Blood Flow Metab. 2011;31(10):1986\u201398. 10.1038\/jcbfm.2011.107.","journal-title":"J Cereb Blood Flow Metab"},{"issue":"13","key":"ref14","doi-asserted-by":"publisher","first-page":"2368","DOI":"10.1007\/s00259-018-4081-5","article-title":"Amyloid involvement in subcortical regions predicts cognitive decline","volume":"45","author":"Cho SH","year":"2018","unstructured":"Cho SH, Shin JH, Jang H, et al. Amyloid involvement in subcortical regions predicts cognitive decline. Eur J Nucl Med Mol Imaging. 2018;45(13):2368\u201376. 10.1007\/s00259-018-4081-5.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"3","key":"ref15","doi-asserted-by":"publisher","first-page":"299","DOI":"10.2967\/jnumed.119.226498","article-title":"First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*","volume":"60","author":"Badawi RD","year":"2019","unstructured":"Badawi RD, Shi H, Hu P, et al. First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*. J Nucl Med. 2019;60(3):299\u2013303. 10.2967\/jnumed.119.226498.","journal-title":"J Nucl Med"},{"issue":"8","key":"ref16","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.2967\/jnumed.121.262668","article-title":"Total-Body PET Multiparametric Imaging of Cancer Using a Voxelwise Strategy of Compartmental Modeling","volume":"63","author":"Wang G","year":"2022","unstructured":"Wang G, Nardo L, Parikh M, et al. Total-Body PET Multiparametric Imaging of Cancer Using a Voxelwise Strategy of Compartmental Modeling. J Nucl Med Off Publ Soc Nucl Med. 2022;63(8):1274\u201381. 10.2967\/jnumed.121.262668.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"issue":"1","key":"ref17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cpet.2020.09.006","article-title":"Clinical Implementation of Total-Body PET\/CT at University of California, Davis","volume":"16","author":"Nardo L","year":"2021","unstructured":"Nardo L, Abdelhafez YG, Spencer BA, Badawi RD. Clinical Implementation of Total-Body PET\/CT at University of California, Davis. PET Clin. 2021;16(1):1\u20137. 10.1016\/j.cpet.2020.09.006.","journal-title":"PET Clin"},{"key":"ref18","article-title":"Florbetaben (18F)","volume":"19","author":"Committe for Medicinal Products for Human Use (CHMP)","year":"2013","unstructured":"Committe for Medicinal Products for Human Use (CHMP). Florbetaben (18F). Published online December 19, 2013.","journal-title":"Published online December"},{"issue":"5","key":"ref19","doi-asserted-by":"publisher","first-page":"723","DOI":"10.2967\/jnumed.112.107185","article-title":"PET quantification of 18F-florbetaben binding to \u03b2-amyloid deposits in human brains","volume":"54","author":"Becker GA","year":"2013","unstructured":"Becker GA, Ichise M, Barthel H, et al. PET quantification of 18F-florbetaben binding to \u03b2-amyloid deposits in human brains. J Nucl Med Off Publ Soc Nucl Med. 2013;54(5):723\u201331. 10.2967\/jnumed.112.107185.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"issue":"3","key":"ref20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1002\/hbm.10062","article-title":"Fast robust automated brain extraction","volume":"17","author":"Smith SM","year":"2002","unstructured":"Smith SM. Fast robust automated brain extraction. Hum Brain Mapp. 2002;17(3):143\u201355. 10.1002\/hbm.10062.","journal-title":"Hum Brain Mapp"},{"issue":"3","key":"ref21","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1007\/s10967-010-0514-8","article-title":"Metabolite analysis of [18F]Florbetaben (BAY 94-9172) in human subjects: a substudy within a proof of mechanism clinical trial","volume":"284","author":"Patt M","year":"2010","unstructured":"Patt M, Schildan A, Barthel H, et al. Metabolite analysis of [18F]Florbetaben (BAY 94-9172) in human subjects: a substudy within a proof of mechanism clinical trial. J Radioanal Nucl Chem. 2010;284(3):557\u201362. 10.1007\/s10967-010-0514-8.","journal-title":"J Radioanal Nucl Chem"},{"issue":"2","key":"ref22","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/s1361-8415(01)00036-6","article-title":"A global optimisation method for robust affine registration of brain images","volume":"5","author":"Jenkinson M","year":"2001","unstructured":"Jenkinson M, Smith S. A global optimisation method for robust affine registration of brain images. Med Image Anal. 2001;5(2):143\u201356. 10.1016\/s1361-8415(01)00036-6.","journal-title":"Med Image Anal"},{"issue":"2","key":"ref23","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1006\/nimg.2002.1132","article-title":"Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images","volume":"17","author":"Jenkinson M","year":"2002","unstructured":"Jenkinson M, Bannister P, Brady M, Smith S. Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images. NeuroImage. 2002;17(2):825\u201341. 10.1006\/nimg.2002.1132.","journal-title":"NeuroImage"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2012.00171","author":"Klein A","year":"2012","unstructured":"Klein A, Tourville J. 101 Labeled Brain Images and a Consistent Human Cortical Labeling Protocol. Front Neurosci. 2012;6. Accessed June 21, 2023. https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2012.00171."},{"issue":"5","key":"ref25","doi-asserted-by":"publisher","first-page":"738","DOI":"10.2967\/jnumed.119.238113","article-title":"Total-Body Quantitative Parametric Imaging of Early Kinetics of 18F-FDG","volume":"62","author":"Feng T","year":"2021","unstructured":"Feng T, Zhao Y, Shi H, et al. Total-Body Quantitative Parametric Imaging of Early Kinetics of 18F-FDG. J Nucl Med Off Publ Soc Nucl Med. 2021;62(5):738\u201344. 10.2967\/jnumed.119.238113.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"issue":"1","key":"ref26","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1111\/j.2517-6161.1995.tb02031.x","article-title":"Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing","volume":"57","author":"Benjamini Y","year":"1995","unstructured":"Benjamini Y, Hochberg Y. Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing. J R Stat Soc Ser B Methodol. 1995;57(1):289\u2013300. 10.1111\/j.2517-6161.1995.tb02031.x.","journal-title":"J R Stat Soc Ser B Methodol"},{"key":"ref27","unstructured":"R Core Team. (2021). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. https:\/\/www.R-project.org\/."},{"issue":"1","key":"ref28","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1038\/s41467-017-01150-x","article-title":"Earliest accumulation of \u03b2-amyloid occurs within the default-mode network and concurrently affects brain connectivity","volume":"8","author":"Palmqvist S","year":"2017","unstructured":"Palmqvist S, Sch\u00f6ll M, Strandberg O, et al. Earliest accumulation of \u03b2-amyloid occurs within the default-mode network and concurrently affects brain connectivity. Nat Commun. 2017;8(1):1214. 10.1038\/s41467-017-01150-x.","journal-title":"Nat Commun"},{"issue":"2","key":"ref29","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1007\/s00259-022-05958-8","article-title":"Cerebral blood flow, amyloid burden, and cognition in cognitively normal individuals","volume":"50","author":"Ebenau JL","year":"2023","unstructured":"Ebenau JL, Visser D, Verfaillie SCJ, et al. Cerebral blood flow, amyloid burden, and cognition in cognitively normal individuals. Eur J Nucl Med Mol Imaging. 2023;50(2):410\u201322. 10.1007\/s00259-022-05958-8.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"4","key":"ref30","doi-asserted-by":"publisher","first-page":"e0122920","DOI":"10.1371\/journal.pone.0122920","article-title":"Quantitative Amyloid Imaging Using Image-Derived Arterial Input Function","volume":"10","author":"Su Y","year":"2015","unstructured":"Su Y, Blazey TM, Snyder AZ, et al. Quantitative Amyloid Imaging Using Image-Derived Arterial Input Function. PLoS ONE. 2015;10(4):e0122920. 10.1371\/journal.pone.0122920.","journal-title":"PLoS ONE"},{"issue":"5","key":"ref31","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.1073\/pnas.1917379117","article-title":"Subsecond total-body imaging using ultrasensitive positron emission tomography","volume":"117","author":"Zhang X","year":"2020","unstructured":"Zhang X, Cherry SR, Xie Z, Shi H, Badawi RD, Qi J. Subsecond total-body imaging using ultrasensitive positron emission tomography. Proc Natl Acad Sci. 2020;117(5):2265\u20137. 10.1073\/pnas.1917379117.","journal-title":"Proc Natl Acad Sci"},{"issue":"4","key":"ref32","doi-asserted-by":"publisher","first-page":"e0232141","DOI":"10.1371\/journal.pone.0232141","article-title":"Optimization of time frame binning for FDOPA uptake quantification in glioma","volume":"15","author":"Girard A","year":"2020","unstructured":"Girard A, Saint-Jalmes H, Chaboub N, et al. Optimization of time frame binning for FDOPA uptake quantification in glioma. PLoS ONE. 2020;15(4):e0232141. 10.1371\/journal.pone.0232141.","journal-title":"PLoS ONE"},{"issue":"1","key":"ref33","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1186\/s13550-023-01050-w","article-title":"An update on the use of image-derived input functions for human PET studies: new hopes or old illusions?","volume":"13","author":"Volpi T","year":"2023","unstructured":"Volpi T, Maccioni L, Colpo M, et al. An update on the use of image-derived input functions for human PET studies: new hopes or old illusions? EJNMMI Res. 2023;13(1):97. 10.1186\/s13550-023-01050-w.","journal-title":"EJNMMI Res"},{"issue":"11","key":"ref34","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.2967\/jnumed.115.171652","article-title":"Cerebellar Amyloid-\u03b2 Plaques: How Frequent Are They, and Do They Influence 18F-Florbetaben SUV Ratios?","volume":"57","author":"Catafau AM","year":"2016","unstructured":"Catafau AM, Bullich S, Seibyl JP, et al. Cerebellar Amyloid-\u03b2 Plaques: How Frequent Are They, and Do They Influence 18F-Florbetaben SUV Ratios? J Nucl Med Off Publ Soc Nucl Med. 2016;57(11):1740\u20135. 10.2967\/jnumed.115.171652.","journal-title":"J Nucl Med Off Publ Soc Nucl Med"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1186\/s13550-020-00714-1","article-title":"[11C]PIB amyloid quantification: effect of reference region selection","volume":"10","author":"Heeman F","year":"2020","unstructured":"Heeman F, Hendriks J, Lopes Alves I, et al. [11C]PIB amyloid quantification: effect of reference region selection. EJNMMI Res. 2020;10:123. 10.1186\/s13550-020-00714-1.","journal-title":"EJNMMI Res"},{"issue":"8","key":"ref36","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.2967\/jnumed.121.262968","article-title":"Efficient Delay Correction for Total-Body PET Kinetic Modeling Using Pulse Timing Methods","volume":"63","author":"Li EJ","year":"2022","unstructured":"Li EJ, Spencer BA, Schmall JP, et al. Efficient Delay Correction for Total-Body PET Kinetic Modeling Using Pulse Timing Methods. J Nucl Med. 2022;63(8):1266\u201373. 10.2967\/jnumed.121.262968.","journal-title":"J Nucl Med"},{"issue":"supplement 2","key":"ref37","first-page":"2329","article-title":"Multi-organ metabolic changes in COVID-19 recovery measured with total-body dynamic 18F-FDG PET","volume":"63","author":"Wang Y","year":"2022","unstructured":"Wang Y, Nardo L, Spencer B, et al. Multi-organ metabolic changes in COVID-19 recovery measured with total-body dynamic 18F-FDG PET. J Nucl Med. 2022;63(supplement 2):2329\u20139.","journal-title":"J Nucl Med"},{"issue":"10","key":"ref38","doi-asserted-by":"publisher","first-page":"3508","DOI":"10.1007\/s00259-022-05784-y","article-title":"Quantification of amyloid PET for future clinical use: a state-of-the-art review","volume":"49","author":"Pemberton HG","year":"2022","unstructured":"Pemberton HG, Collij LE, Heeman F, et al. Quantification of amyloid PET for future clinical use: a state-of-the-art review. Eur J Nucl Med Mol Imaging. 2022;49(10):3508\u201328. 10.1007\/s00259-022-05784-y.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s13550-018-0412-6","article-title":"Non-invasive kinetic modelling of PET tracers with radiometabolites using a constrained simultaneous estimation method: evaluation with 11C-SB201745","volume":"8","author":"Sari H","year":"2018","unstructured":"Sari H, Erlandsson K, Marner L, et al. Non-invasive kinetic modelling of PET tracers with radiometabolites using a constrained simultaneous estimation method: evaluation with 11C-SB201745. EJNMMI Res. 2018;8:58. 10.1186\/s13550-018-0412-6.","journal-title":"EJNMMI Res"},{"issue":"9","key":"ref40","doi-asserted-by":"publisher","first-page":"5145","DOI":"10.1118\/1.4961012","article-title":"Time-integrated activity coefficient estimation for radionuclide therapy using PET and a pharmacokinetic model: A simulation study on the effect of sampling schedule and noise","volume":"43","author":"Hardiansyah D","year":"2016","unstructured":"Hardiansyah D, Guo W, Kletting P, Mottaghy FM, Glatting G. Time-integrated activity coefficient estimation for radionuclide therapy using PET and a pharmacokinetic model: A simulation study on the effect of sampling schedule and noise. Med Phys. 2016;43(9):5145\u201354. 10.1118\/1.4961012.","journal-title":"Med Phys"},{"issue":"7","key":"ref41","doi-asserted-by":"publisher","first-page":"796","DOI":"10.3390\/ph15070796","article-title":"Physiologically Based Pharmacokinetic (PBPK) Modeling to Predict PET Image Quality of Three Generations EGFR TKI in Advanced-Stage NSCLC Patients","volume":"15","author":"Bartelink IH","year":"2022","unstructured":"Bartelink IH, van de Stadt EA, Leeuwerik AF, et al. Physiologically Based Pharmacokinetic (PBPK) Modeling to Predict PET Image Quality of Three Generations EGFR TKI in Advanced-Stage NSCLC Patients. Pharmaceuticals. 2022;15(7):796. 10.3390\/ph15070796.","journal-title":"Pharmaceuticals"}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3764930\/v1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3764930\/v1.html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T16:15:47Z","timestamp":1713284147000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchsquare.com\/article\/rs-3764930\/v1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,27]]},"references-count":41,"URL":"https:\/\/doi.org\/10.21203\/rs.3.rs-3764930\/v1","relation":{"is-preprint-of":[{"id-type":"doi","id":"10.1186\/s13550-024-01104-7","asserted-by":"subject"}]},"subject":[],"published":{"date-parts":[[2023,12,27]]},"subtype":"preprint"}}