{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"Research Square"}],"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T13:40:32Z","timestamp":1787060432240,"version":"build-2736575974"},"posted":{"date-parts":[[2024,7,17]]},"group-title":"In Review","reference-count":45,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T00:00:00Z","timestamp":1721174400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2024,7,10]]},"abstract":"<title>Abstract<\/title>\n                <p>\n                  Ultrasonography is a vital component of modern clinical care, with handheld probes routinely used for a variety of applications. However, handheld ultrasound imaging is limited by factors such as the partial-body field of view, operator dependency, contact-induced distortion, and lack of transmission contrast. Here, we demonstrate a new system enabling whole-body ultrasound tomography of humans in reflection and transmission modes. To generate 2D isotropically resolved images across the entire cross-section\n                  <italic>in vivo<\/italic>\n                  , we use a custom 512-element circular ultrasound receiver array with a rotating ultrasonic transmitter. We demonstrate this technique in regions such as the abdomen and legs in healthy volunteers. We also showcase two potential clinical extensions. First, we readily observe subcutaneous and preperitoneal abdominal adipose distributions in our images, enabling adipose thickness assessment over the body without ionizing radiation or mechanical deformation. Second, we demonstrate an approach for rapid (seven frame-per-second) biopsy needle localization with respect to internal tissue features. These capabilities make whole-body ultrasound tomography a potential practical tool for clinical needs currently unmet by other modalities.\n                <\/p>","DOI":"10.21203\/rs.3.rs-4714949\/v1","type":"posted-content","created":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T00:09:28Z","timestamp":1721174968000},"source":"Crossref","is-referenced-by-count":1,"title":["Whole-Body Human Ultrasound Tomography"],"prefix":"10.21203","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9783-4383","authenticated-orcid":false,"given":"Lihong","family":"Wang","sequence":"first","affiliation":[{"name":"California Institute of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9747-8494","authenticated-orcid":false,"given":"David","family":"Garrett","sequence":"additional","affiliation":[{"name":"California Institute of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinhua","family":"Xu","sequence":"additional","affiliation":[{"name":"California Institute of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9527-8923","authenticated-orcid":false,"given":"Yousuf","family":"Aborahama","sequence":"additional","affiliation":[{"name":"California Institute of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geng","family":"Ku","sequence":"additional","affiliation":[{"name":"California Institute of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantin","family":"Maslov","sequence":"additional","affiliation":[{"name":"California Institute of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"issue":"1","key":"ref1","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1007\/BF02233558","article-title":"Ultrasonic diagnosis of abdominal disease","volume":"8","author":"Holmes JH","year":"1963","unstructured":"J. H. Holmes and D. H. Howry, \u201cUltrasonic diagnosis of abdominal disease,\u201d Am. J. Dig. Dis., vol. 8, no. 1, pp. 12\u201332, Jan. 1963, doi: 10.1007\/BF02233558.","journal-title":"Am. J. Dig. Dis."},{"issue":"4","key":"ref2","first-page":"579","article-title":"Ultrasonic visualization of soft tissue structures of the body","volume":"40","author":"Howry DH","year":"1952","unstructured":"D. H. Howry and W. R. Bliss, \u201cUltrasonic visualization of soft tissue structures of the body,\u201d J. Lab. Clin. Med., vol. 40, no. 4, pp. 579\u2013592, 1952.","journal-title":"J. Lab. Clin. Med."},{"issue":"1","key":"ref3","doi-asserted-by":"crossref","first-page":"189","DOI":"10.2214\/ajr.160.1.8416623","article-title":"Early history of diagnostic ultrasound: the role of American radiologists","volume":"160","author":"Goldberg BB","year":"1993","unstructured":"B. B. Goldberg, R. Gramiak, and A. K. Freimanis, \u201cEarly history of diagnostic ultrasound: the role of American radiologists,\u201d AJR Am J Roentgenol, vol. 160, no. 1, pp. 189\u2013194, 1993.","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"ref4","first-page":"333","article-title":"Ultrasonic scanning in diagnosis of abdominal disease","volume":"134","author":"Holm HH","year":"1968","unstructured":"H. H. Holm and T. Mortensen, \u201cUltrasonic scanning in diagnosis of abdominal disease,\u201d Acta Chir. Scand., vol. 134, no. 5, pp. 333\u2013341, 1968.","journal-title":"Acta Chir. Scand."},{"key":"ref5","author":"Howry DH","year":"1955","unstructured":"D. H. Howry, J. H. Holmes, C. R. Cushman, and G. J. Posakony, \u201cUltrasonic visualization of living organs and tissues; with observations on some disease processes,\u201d Geriatrics, vol. 10, no. 3, pp. 123\u2013128, Mar. 1955."},{"issue":"517","key":"ref6","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1259\/0007-1285-44-517-24","article-title":"\u201cUltrasonic scanning in the diagnosis of space-occupying lesions of the upper abdomen","volume":"44","author":"Holm HH","year":"1971","unstructured":"H. H. Holm, \u201cUltrasonic scanning in the diagnosis of space-occupying lesions of the upper abdomen,\u201d Br. J. Radiol., vol. 44, no. 517, pp. 24\u201336, Jan. 1971, doi: 10.1259\/0007-1285-44-517-24.","journal-title":"Br. J. Radiol."},{"issue":"7032","key":"ref7","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1016\/s0140-6736(58)91905-6","article-title":"Investigation of abdominal masses by pulsed ultrasound","volume":"1","author":"Donald I","year":"1958","unstructured":"I. Donald, J. Macvicar, and T. G. Brown, \u201cInvestigation of abdominal masses by pulsed ultrasound,\u201d Lancet Lond. Engl., vol. 1, no. 7032, pp. 1188\u20131195, Jun. 1958, doi: 10.1016\/s0140-6736(58)91905-6.","journal-title":"Lancet Lond. Engl."},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1159\/000487156","author":"Pinto J","year":"2018","unstructured":"J. Pinto, R. Azevedo, E. Pereira, and A. Caldeira, \u201cUltrasonography in Gastroenterology: The Need for Training,\u201d GE Port. J. Gastroenterol., vol. 25, no. 6, pp. 308\u2013316, Nov. 2018, doi: 10.1159\/000487156."},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-010-1402-1","author":"Noorkoiv M","year":"2010","unstructured":"M. Noorkoiv, K. Nosaka, and A. J. Blazevich, \u201cAssessment of quadriceps muscle cross-sectional area by ultrasound extended-field-of-view imaging,\u201d Eur. J. Appl. Physiol., vol. 109, no. 4, pp. 631\u2013639, Jul. 2010, doi: 10.1007\/s00421-010-1402-1."},{"issue":"3","key":"ref10","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1148\/radiology.203.3.9169720","article-title":"\u201cUS extended-field-of-view imaging technology","volume":"203","author":"Weng L","year":"1997","unstructured":"L. Weng et al., \u201cUS extended-field-of-view imaging technology.,\u201d Radiology, vol. 203, no. 3, pp. 877\u2013880, Jun. 1997, doi: 10.1148\/radiology.203.3.9169720.","journal-title":"Radiology"},{"issue":"5","key":"ref11","doi-asserted-by":"publisher","first-page":"335","DOI":"10.7863\/jum.1999.18.5.335","article-title":"Extended field-of-view sonography: utility in clinical practice","volume":"18","author":"Sauerbrei EE","year":"1999","unstructured":"E. E. Sauerbrei, \u201cExtended field-of-view sonography: utility in clinical practice.,\u201d J. Ultrasound Med., vol. 18, no. 5, pp. 335\u2013341, 1999, doi: 10.7863\/jum.1999.18.5.335.","journal-title":"J. Ultrasound Med."},{"issue":"4","key":"ref12","doi-asserted-by":"publisher","first-page":"385","DOI":"10.7863\/jum.2003.22.4.385","article-title":"Extended Field-of-View Sonography","volume":"22","author":"Kim SH","year":"2003","unstructured":"S. H. Kim, B. I. Choi, K. W. Kim, K. H. Lee, and J. K. Han, \u201cExtended Field-of-View Sonography,\u201d J. Ultrasound Med., vol. 22, no. 4, pp. 385\u2013394, 2003, doi: 10.7863\/jum.2003.22.4.385.","journal-title":"J. Ultrasound Med."},{"issue":"5","key":"ref13","doi-asserted-by":"publisher","first-page":"3802","DOI":"10.1121\/1.3699240","article-title":"Non-linear inverse scattering: High resolution quantitative breast tissue tomography","volume":"131","author":"Wiskin J","year":"2012","unstructured":"J. Wiskin, D. T. Borup, S. A. Johnson, and M. Berggren, \u201cNon-linear inverse scattering: High resolution quantitative breast tissue tomography,\u201d J. Acoust. Soc. Am., vol. 131, no. 5, pp. 3802\u20133813, May 2012, doi: 10.1121\/1.3699240.","journal-title":"J. Acoust. Soc. Am."},{"key":"ref14","first-page":"98","volume-title":"Medical Imaging 2016: Physics of Medical Imaging","author":"Huang L","year":"2016","unstructured":"L. Huang et al., \u201cBreast ultrasound tomography with two parallel transducer arrays,\u201d in Medical Imaging 2016: Physics of Medical Imaging, SPIE, Mar. 2016, pp. 98\u2013109. doi: 10.1117\/12.2216531."},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2020.3017815","author":"Zhang Y","year":"2020","unstructured":"Y. Zhang and L. Wang, \u201cVideo-Rate Ring-Array Ultrasound and Photoacoustic Tomography,\u201d IEEE Trans. Med. Imaging, vol. 39, no. 12, pp. 4369\u20134375, Dec. 2020, doi: 10.1109\/TMI.2020.3017815."},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1121\/1.4876990","author":"Duric N","year":"2014","unstructured":"N. Duric et al., \u201cClinical breast imaging with ultrasound tomography: A description of the SoftVue system,\u201d J. Acoust. Soc. Am., vol. 135, no. 4_Supplement, p. 2155, Apr. 2014, doi: 10.1121\/1.4876990."},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/ULTSYM.2019.8925778","author":"Wiskin J","year":"2019","unstructured":"J. Wiskin et al., \u201cFull Wave 3D Inverse Scattering Transmission Ultrasound Tomography: Breast and Whole Body Imaging,\u201d in 2019 IEEE International Ultrasonics Symposium (IUS), Oct. 2019, pp. 951\u2013958. doi: 10.1109\/ULTSYM.2019.8925778."},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2023.01.018","article-title":"Whole-Body Imaging Using Low Frequency Transmission Ultrasound","author":"Wiskin J","year":"2023","unstructured":"J. Wiskin, B. Malik, C. Ruoff, N. Pirshafiey, M. Lenox, and J. Klock, \u201cWhole-Body Imaging Using Low Frequency Transmission Ultrasound,\u201d Acad. Radiol., Feb. 2023, doi: 10.1016\/j.acra.2023.01.018.","journal-title":"Acad. Radiol."},{"key":"ref19","doi-asserted-by":"publisher","first-page":"eadg8176","DOI":"10.1126\/sciadv.adg8176","article-title":"Fast volumetric ultrasound facilitates high-resolution 3D mapping of tissue compartments","volume":"9","author":"Park E-Y","year":"2023","unstructured":"E.-Y. Park et al., \u201cFast volumetric ultrasound facilitates high-resolution 3D mapping of tissue compartments,\u201d Sci. Adv., vol. 9, no. 22, p. eadg8176, May 2023, doi: 10.1126\/sciadv.adg8176.","journal-title":"Sci. Adv."},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.48550\/arXiv.2304.02643","article-title":"Segment Anything.\u201d arXiv","volume":"05","author":"Kirillov A","year":"2023","unstructured":"A. Kirillov et al., \u201cSegment Anything.\u201d arXiv, Apr. 05, 2023. doi: 10.48550\/arXiv.2304.02643.","journal-title":"Apr."},{"key":"ref21","volume-title":"Diagnostic Ultrasound Imaging: Inside Out","author":"Szabo TL","year":"2004","unstructured":"T. L. Szabo, Diagnostic Ultrasound Imaging: Inside Out. Academic Press, 2004."},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.13099\/VIP21000-04-2","article-title":"Tissue Properties Database V4.2.\u201d","author":"Foundation IT\u2019IS","year":"2024","unstructured":"IT\u2019IS Foundation, \u201cTissue Properties Database V4.2.\u201d IT\u2019IS Foundation, 2024. doi: 10.13099\/VIP21000-04-2.","journal-title":"IT\u2019IS Foundation"},{"issue":"5","key":"ref23","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1586\/17474124.2015.1007955","article-title":"Role of ultrasound in the diagnosis and treatment of nonalcoholic fatty liver disease and its complications","volume":"9","author":"Ballestri S","year":"2015","unstructured":"S. Ballestri, D. Romagnoli, F. Nascimbeni, G. Francica, and A. Lonardo, \u201cRole of ultrasound in the diagnosis and treatment of nonalcoholic fatty liver disease and its complications,\u201d Expert Rev. Gastroenterol. Hepatol., vol. 9, no. 5, pp. 603\u2013627, May 2015, doi: 10.1586\/17474124.2015.1007955.","journal-title":"Expert Rev. Gastroenterol. Hepatol."},{"issue":"1","key":"ref24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.mam.2012.10.001","article-title":"Adipose tissue heterogeneity: Implication of depot differences in adipose tissue for obesity complications","volume":"34","author":"Lee M-J","year":"2013","unstructured":"M.-J. Lee, Y. Wu, and S. K. Fried, \u201cAdipose tissue heterogeneity: Implication of depot differences in adipose tissue for obesity complications,\u201d Mol. Aspects Med., vol. 34, no. 1, pp. 1\u201311, Feb. 2013, doi: 10.1016\/j.mam.2012.10.001.","journal-title":"Mol. Aspects Med."},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1093\/ajcn\/45.4.717","author":"Kuczmarski RJ","year":"1987","unstructured":"R. J. Kuczmarski, M. T. Fanelli, and G. G. Koch, \u201cUltrasonic assessment of body composition in obese adults: overcoming the limitations of the skinfold caliper,\u201d Am. J. Clin. Nutr., vol. 45, no. 4, pp. 717\u2013724, Apr. 1987, doi: 10.1093\/ajcn\/45.4.717."},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1038\/sj.ijo.0802398","author":"Liu KH","year":"2003","unstructured":"K. H. Liu, Y. L. Chan, W. B. Chan, W. L. Kong, M. O. Kong, and J. C. N. Chan, \u201cSonographic measurement of mesenteric fat thickness is a good correlate with cardiovascular risk factors: comparison with subcutaneous and preperitoneal fat thickness, magnetic resonance imaging and anthropometric indexes,\u201d Int. J. Obes., vol. 27, no. 10, Art. no. 10, Oct. 2003, doi: 10.1038\/sj.ijo.0802398."},{"issue":"9","key":"ref27","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1002\/lsm.23604","article-title":"Utility of high-resolution ultrasound in measuring subcutaneous fat thickness","volume":"54","author":"Anvery N","year":"2022","unstructured":"N. Anvery et al., \u201cUtility of high-resolution ultrasound in measuring subcutaneous fat thickness,\u201d Lasers Surg. Med., vol. 54, no. 9, pp. 1189\u20131197, 2022, doi: 10.1002\/lsm.23604.","journal-title":"Lasers Surg. Med."},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-19937-4","author":"Hoffmann J","year":"2022","unstructured":"J. Hoffmann et al., \u201cMeasurement of subcutaneous fat tissue: reliability and comparison of caliper and ultrasound via systematic body mapping,\u201d Sci. Rep., vol. 12, no. 1, Art. no. 1, Sep. 2022, doi: 10.1038\/s41598-022-19937-4."},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjps.2012.12.003","author":"Harley OJH","year":"2013","unstructured":"O. J. H. Harley and M. A. Pickford, \u201cCT analysis of fat distribution superficial and deep to the Scarpa\u2019s fascial layer in the mid and lower abdomen,\u201d J. Plast. Reconstr. Aesthet. Surg., vol. 66, no. 4, pp. 525\u2013530, Apr. 2013, doi: 10.1016\/j.bjps.2012.12.003."},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-006-0142-8","author":"Abu-Hijleh MF","year":"2006","unstructured":"M. F. Abu-Hijleh, A. L. Roshier, Q. Al-Shboul, A. S. Dharap, and P. F. Harris, \u201cThe membranous layer of superficial fascia: evidence for its widespread distribution in the body,\u201d Surg. Radiol. Anat., vol. 28, no. 6, pp. 606\u2013619, Dec. 2006, doi: 10.1007\/s00276-006-0142-8."},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-010-0772-8","author":"Lancerotto L","year":"2011","unstructured":"L. Lancerotto, C. Stecco, V. Macchi, A. Porzionato, A. Stecco, and R. De Caro, \u201cLayers of the abdominal wall: anatomical investigation of subcutaneous tissue and superficial fascia,\u201d Surg. Radiol. Anat., vol. 33, no. 10, pp. 835\u2013842, Dec. 2011, doi: 10.1007\/s00276-010-0772-8."},{"issue":"6","key":"ref32","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1002\/osp4.453","article-title":"Ultrasound measures of abdominal fat layers correlate with metabolic syndrome features in patients with obesity","volume":"6","author":"Cuatrecasas G","year":"2020","unstructured":"G. Cuatrecasas et al., \u201cUltrasound measures of abdominal fat layers correlate with metabolic syndrome features in patients with obesity,\u201d Obes. Sci. Pract., vol. 6, no. 6, pp. 660\u2013667, 2020, doi: 10.1002\/osp4.453.","journal-title":"Obes. Sci. Pract."},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1007\/s00266-002-1516-x","author":"Graf R","year":"2003","unstructured":"R. Graf and R. C. C. D. Andr\u00e9 Auersvald Ronald Rippel,Luiz Roberto Reis de Ara\u00fajo, Luiz Henrique Camargo Bigarelli, and Claudio Luciano Franck, \u201cUltrasound-Assisted Liposuction: An Analysis of 348 Cases,\u201d Aesthetic Plast. Surg., vol. 27, no. 2, pp. 146\u2013153, Apr. 2003, doi: 10.1007\/s00266-002-1516-x."},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-013-9980-0","author":"Sainani NI","year":"2013","unstructured":"N. I. Sainani, R. S. Arellano, P. B. Shyn, D. A. Gervais, P. R. Mueller, and S. G. Silverman, \u201cThe challenging image-guided abdominal mass biopsy: established and emerging techniques \u2018if you can see it, you can biopsy it,\u2019\u201d Abdom. Imaging, vol. 38, no. 4, pp. 672\u2013696, Aug. 2013, doi: 10.1007\/s00261-013-9980-0."},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1115\/1.4031050","author":"Li W","year":"2015","unstructured":"W. Li, Y. Wang, V. Nteziyaremye, H. Yamaguchi, and A. J. Shih, \u201cMeasurement of the Friction Force Inside the Needle in Biopsy,\u201d J. Manuf. Sci. Eng., vol. 138, no. 031003, Oct. 2015, doi: 10.1115\/1.4031050."},{"key":"ref36","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1053\/j.gastro.2023.01.021","article-title":"\u201cIntestinal Ultrasound in the Assessment and Management of Inflammatory Bowel Disease: Is It Ready for Standard Practice?","volume":"164","author":"Allocca M","year":"2023","unstructured":"M. Allocca, T. Kucharzik, and D. T. Rubin, \u201cIntestinal Ultrasound in the Assessment and Management of Inflammatory Bowel Disease: Is It Ready for Standard Practice?,\u201d Gastroenterology, vol. 164, no. 6, pp. 851\u2013855, May 2023, doi: 10.1053\/j.gastro.2023.01.021.","journal-title":"Gastroenterology"},{"issue":"6696","key":"ref37","doi-asserted-by":"publisher","first-page":"eadm7168","DOI":"10.1126\/science.adm7168","article-title":"Whole-body magnetic resonance imaging at 0.05 Tesla","volume":"384","author":"Zhao Y","year":"2024","unstructured":"Y. Zhao et al., \u201cWhole-body magnetic resonance imaging at 0.05 Tesla,\u201d Science, vol. 384, no. 6696, p. eadm7168, May 2024, doi: 10.1126\/science.adm7168.","journal-title":"Science"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1007\/s43154-020-00042-1","author":"Siepel FJ","year":"2021","unstructured":"F. J. Siepel, B. Maris, M. K. Welleweerd, V. Groenhuis, P. Fiorini, and S. Stramigioli, \u201cNeedle and Biopsy Robots: a Review,\u201d Curr. Robot. Rep., vol. 2, no. 1, pp. 73\u201384, Mar. 2021, doi: 10.1007\/s43154-020-00042-1."},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1007\/BF02926533","author":"Pfister RC","year":"1988","unstructured":"R. C. Pfister, N. Papanicolaou, and I. C. Yoder, \u201cUrinary extracorporeal shock wave lithotripsy: Equipment, techniques, and overview,\u201d Urol. Radiol., vol. 10, no. 1, pp. 39\u201345, Dec. 1988, doi: 10.1007\/BF02926533."},{"key":"ref40","doi-asserted-by":"publisher","first-page":"106855","DOI":"10.1016\/j.cmpb.2022.106855","article-title":"\u201cStride: A flexible software platform for high-performance ultrasound computed tomography","volume":"221","author":"Cueto C","year":"2022","unstructured":"C. Cueto et al., \u201cStride: A flexible software platform for high-performance ultrasound computed tomography,\u201d Comput. Methods Programs Biomed., vol. 221, p. 106855, Jun. 2022, doi: 10.1016\/j.cmpb.2022.106855.","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1038\/s41551-017-0071","author":"Li L","year":"2017","unstructured":"L. Li et al., \u201cSingle-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution,\u201d Nat. Biomed. Eng., vol. 1, no. 5, Art. no. 5, May 2017, doi: 10.1038\/s41551-017-0071."},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-018-04576-z","author":"Lin L","year":"2018","unstructured":"L. Lin et al., \u201cSingle-breath-hold photoacoustic computed tomography of the breast,\u201d Nat. Commun., vol. 9, no. 1, Art. no. 1, Jun. 2018, doi: 10.1038\/s41467-018-04576-z."},{"key":"ref43","doi-asserted-by":"publisher","first-page":"100520","DOI":"10.1016\/j.pacs.2023.100520","article-title":"\u201cA method for the geometric calibration of ultrasound transducer arrays with arbitrary geometries","volume":"32","author":"Sastry K","year":"2023","unstructured":"K. Sastry et al., \u201cA method for the geometric calibration of ultrasound transducer arrays with arbitrary geometries,\u201d Photoacoustics, vol. 32, p. 100520, Aug. 2023, doi: 10.1016\/j.pacs.2023.100520.","journal-title":"Photoacoustics"},{"issue":"3","key":"ref44","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1109\/58.143168","article-title":"\u201cCoded excitation system for improving the penetration of real-time phased-array imaging systems","volume":"39","author":"O\u2019Donnell M","year":"1992","unstructured":"M. O\u2019Donnell, \u201cCoded excitation system for improving the penetration of real-time phased-array imaging systems,\u201d IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 39, no. 3, pp. 341\u2013351, May 1992, doi: 10.1109\/58.143168.","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-5629(00)00204-0","author":"Barnett SB","year":"2000","unstructured":"S. B. Barnett, G. R. Ter Haar, M. C. Ziskin, H.-D. Rott, F. A. Duck, and K. Maeda, \u201cInternational recommendations and guidelines for the safe use of diagnostic ultrasound in medicine,\u201d Ultrasound Med. Biol., vol. 26, no. 3, pp. 355\u2013366, Mar. 2000, doi: 10.1016\/S0301-5629(00)00204-0."}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/www.researchsquare.com\/article\/rs-4714949\/v1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.researchsquare.com\/article\/rs-4714949\/v1.html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T07:08:06Z","timestamp":1777100886000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchsquare.com\/article\/rs-4714949\/v1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,17]]},"references-count":45,"URL":"https:\/\/doi.org\/10.21203\/rs.3.rs-4714949\/v1","relation":{"is-preprint-of":[{"id-type":"doi","id":"10.1038\/s41551-026-01660-4","asserted-by":"subject"}]},"subject":[],"published":{"date-parts":[[2024,7,17]]},"subtype":"preprint"}}