{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"Research Square"}],"indexed":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T19:21:52Z","timestamp":1768245712529,"version":"3.49.0"},"posted":{"date-parts":[[2025,4,16]]},"group-title":"In Review","reference-count":36,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T00:00:00Z","timestamp":1744761600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2025,3,21]]},"abstract":"<title>Abstract<\/title>\n                <p>2D CMR is critical for monitoring PR fraction (PRF) and biventricular size in patients with a history of repaired tetralogy of Fallot and guides decisions about pulmonary valve replacement (PVR). However, its clinical utility is limited, increasing enthusiasm for newer techniques such as 3D time-resolved phase contrast (4D flow) MRI. We investigated whether using 4D flow to calculate PRF would yield similar clinical decisions about PVR in rTOF compared to conventional 2D CMR.\n \nAll patients with rTOF who underwent standard CMR plus retrospectively gated 4D flow between February 2021 \u2013 June 2023 were identified. Clinical information was collected from the EMR. 2D cine SSFP, phase contrast (PC) data, and 4D flow imaging data were analyzed using standard post-processing analysis. Clinical decisions (\u201cintervention vs. no intervention\u201d) were determined using a standardized algorithm, and inter-rater agreement was assessed using the  coefficient.\n \n33 patients were included. PRF correlated strongly between 2D PC and 4D flow (r=0.83) and with PRF determined by stroke volume (r=0.70). The mean absolute difference between 2D and 4D PRF was -3.4% (\u00b1 9.3%). Inter-rater agreement for the decision was moderate (=0.58) using only 2D PC and 4D flow, and was strong (=0.76) when using 2D PC with SV and 4D flow with SV. Though clinical indications for PVR in rTOF vary, 4D flow generates accurate measurements of PRF and yields similar clinical decisions about intervention in rTOF. Further study of ventricular volume assessment by 4D flow adoption could lead to a shorter, more comprehensive CMR exam for TOF patients.<\/p>","DOI":"10.21203\/rs.3.rs-6280623\/v1","type":"posted-content","created":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T04:53:46Z","timestamp":1744779226000},"source":"Crossref","is-referenced-by-count":0,"title":["4D flow yields similar clinical results compared to 2D phase contrast for decision making regarding pulmonary valve replacement in repaired tetralogy of Fallot"],"prefix":"10.21203","author":[{"given":"Alison","family":"Almgren-Bell","sequence":"first","affiliation":[{"name":"Northwestern University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrada","family":"Popescu","sequence":"additional","affiliation":[{"name":"Lurie Children's Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aparna","family":"Sodhi","sequence":"additional","affiliation":[{"name":"Lurie Children's Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Markl","sequence":"additional","affiliation":[{"name":"Northwestern University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cynthia","family":"Rigsby","sequence":"additional","affiliation":[{"name":"Lurie Children's Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua","family":"Robinson","sequence":"additional","affiliation":[{"name":"Lurie Children's Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"issue":"9699","key":"ref1","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1016\/S0140-6736(09)60657-7","volume":"374","author":"Apitz C","year":"2009","unstructured":"Apitz C, Webb GD, Redington AN (2009) Tetralogy Fallot Lancet 374(9699):1462\u20131471","journal-title":"Tetralogy Fallot Lancet"},{"issue":"18","key":"ref2","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1002\/bdr2.1589","article-title":"National population-based estimates for major birth defects, 2010\u20132014","volume":"111","author":"Mai CT","year":"2019","unstructured":"Mai CT et al (2019) National population-based estimates for major birth defects, 2010\u20132014. Birth Defects Res 111(18):1420\u20131435","journal-title":"Birth Defects Res"},{"issue":"9234","key":"ref3","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/S0140-6736(00)02714-8","article-title":"Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre study","volume":"356","author":"Gatzoulis MA","year":"2000","unstructured":"Gatzoulis MA et al (2000) Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre study. Lancet 356(9234):975\u2013981","journal-title":"Lancet"},{"issue":"1","key":"ref4","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/1532-429X-13-9","article-title":"Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision support","volume":"13","author":"Geva T","year":"2011","unstructured":"Geva T (2011) Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision support. J Cardiovasc Magn Reson 13(1):9","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"ref5","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s12968-021-00745-0","article-title":"Four-dimensional flow cardiovascular magnetic resonance in tetralogy of Fallot: a systematic review","volume":"23","author":"Elsayed A","year":"2021","unstructured":"Elsayed A et al (2021) Four-dimensional flow cardiovascular magnetic resonance in tetralogy of Fallot: a systematic review. J Cardiovasc Magn Reson 23(1):59","journal-title":"J Cardiovasc Magn Reson"},{"issue":"5","key":"ref6","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1016\/S0735-1097(97)00318-5","article-title":"Long-term survival in patients with repair of tetralogy of Fallot: 36-year follow-up of 490 survivors of the first year after surgical repair","volume":"30","author":"Nollert G","year":"1997","unstructured":"Nollert G et al (1997) Long-term survival in patients with repair of tetralogy of Fallot: 36-year follow-up of 490 survivors of the first year after surgical repair. J Am Coll Cardiol 30(5):1374\u20131383","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"ref7","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/RTI.0000000000000478","article-title":"Preprocedural Imaging Evaluation of Pulmonary Valve Replacement After Repair of Tetralogy of Fallot: What the Radiologist Needs to Know","volume":"35","author":"Flors L","year":"2020","unstructured":"Flors L et al (2020) Preprocedural Imaging Evaluation of Pulmonary Valve Replacement After Repair of Tetralogy of Fallot: What the Radiologist Needs to Know. J Thorac Imaging 35(3):153\u2013166","journal-title":"J Thorac Imaging"},{"issue":"3","key":"ref8","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1007\/s00246-018-2035-0","article-title":"Can Abbreviated Cardiac Magnetic Resonance Imaging Adequately Support Clinical Decision Making After Repair of Tetralogy of Fallot?","volume":"40","author":"House AV","year":"2019","unstructured":"House AV et al (2019) Can Abbreviated Cardiac Magnetic Resonance Imaging Adequately Support Clinical Decision Making After Repair of Tetralogy of Fallot? Pediatr Cardiol 40(3):616\u2013622","journal-title":"Pediatr Cardiol"},{"issue":"1","key":"ref9","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/s12968-023-00942-z","article-title":"4D Flow cardiovascular magnetic resonance consensus statement: 2023 update","volume":"25","author":"Bissell MM","year":"2023","unstructured":"Bissell MM et al (2023) 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update. J Cardiovasc Magn Reson 25(1):40","journal-title":"J Cardiovasc Magn Reson"},{"issue":"6","key":"ref10","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1136\/heartjnl-2019-315797","article-title":"Three-dimensional and four-dimensional flow assessment in congenital heart disease","volume":"106","author":"Warmerdam E","year":"2020","unstructured":"Warmerdam E et al (2020) Three-dimensional and four-dimensional flow assessment in congenital heart disease. Heart 106(6):421\u2013426","journal-title":"Heart"},{"issue":"9","key":"ref11","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1007\/s11748-018-0931-0","article-title":"Pulmonary valve replacement after repaired Tetralogy of Fallot","volume":"66","author":"Tatewaki H","year":"2018","unstructured":"Tatewaki H, Shiose A (2018) Pulmonary valve replacement after repaired Tetralogy of Fallot. Gen Thorac Cardiovasc Surg 66(9):509\u2013515","journal-title":"Gen Thorac Cardiovasc Surg"},{"issue":"10","key":"ref12","first-page":"838","article-title":"Impact of Percutaneous Pulmonary Valve Implantation on the Timing of Reintervention for Right Ventricular Outflow Tract Dysfunction","volume":"71","author":"Torres-Alba F","year":"2018","unstructured":"de Torres-Alba F, Kaleschke G, Baumgartner H (2018) Impact of Percutaneous Pulmonary Valve Implantation on the Timing of Reintervention for Right Ventricular Outflow Tract Dysfunction. Rev Esp Cardiol (Engl Ed) 71(10):838\u2013846","journal-title":"Rev Esp Cardiol (Engl Ed)"},{"issue":"4","key":"ref13","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/s10554-019-01751-1","article-title":"4D flow vs. 2D cardiac MRI for the evaluation of pulmonary regurgitation and ventricular volume in repaired tetralogy of Fallot: a retrospective case control study","volume":"36","author":"Jacobs KG","year":"2020","unstructured":"Jacobs KG et al (2020) 4D flow vs. 2D cardiac MRI for the evaluation of pulmonary regurgitation and ventricular volume in repaired tetralogy of Fallot: a retrospective case control study. Int J Cardiovasc Imaging 36(4):657\u2013669","journal-title":"Int J Cardiovasc Imaging"},{"issue":"1","key":"ref14","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/1532-429X-15-51","article-title":"Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease","volume":"15","author":"Fratz S","year":"2013","unstructured":"Fratz S et al (2013) Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease. J Cardiovasc Magn Reson 15(1):51","journal-title":"J Cardiovasc Magn Reson"},{"issue":"2","key":"ref15","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.ahj.2005.03.058","article-title":"Cardiovascular magnetic resonance in the follow-up of patients with corrected tetralogy of Fallot: a review","volume":"151","author":"Oosterhof T","year":"2006","unstructured":"Oosterhof T et al (2006) Cardiovascular magnetic resonance in the follow-up of patients with corrected tetralogy of Fallot: a review. Am Heart J 151(2):265\u2013272","journal-title":"Am Heart J"},{"issue":"1","key":"ref16","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/s12968-015-0174-5","article-title":"4D flow cardiovascular magnetic resonance consensus statement","volume":"17","author":"Dyverfeldt P","year":"2015","unstructured":"Dyverfeldt P et al (2015) 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 17(1):72","journal-title":"J Cardiovasc Magn Reson"},{"issue":"6","key":"ref17","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1007\/s00247-014-3246-z","article-title":"4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography","volume":"45","author":"Gabbour M","year":"2015","unstructured":"Gabbour M et al (2015) 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography. Pediatr Radiol 45(6):804\u2013813","journal-title":"Pediatr Radiol"},{"issue":"3","key":"ref18","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1002\/jmri.22280","article-title":"Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study","volume":"32","author":"Nordmeyer S","year":"2010","unstructured":"Nordmeyer S et al (2010) Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study. J Magn Reson Imaging 32(3):677\u2013683","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"ref19","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s12968-022-00843-7","article-title":"Society for Cardiovascular Magnetic Resonance\/European Society of Cardiovascular Imaging\/American Society of Echocardiography\/Society for Pediatric Radiology\/North American Society for Cardiovascular Imaging Guidelines for the use of cardiovascular magnetic resonance in pediatric congenital and acquired heart disease: Endorsed by The American Heart Association","volume":"24","author":"Fogel MA","year":"2022","unstructured":"Fogel MA et al (2022) Society for Cardiovascular Magnetic Resonance\/European Society of Cardiovascular Imaging\/American Society of Echocardiography\/Society for Pediatric Radiology\/North American Society for Cardiovascular Imaging Guidelines for the use of cardiovascular magnetic resonance in pediatric congenital and acquired heart disease: Endorsed by The American Heart Association. J Cardiovasc Magn Reson 24(1):37","journal-title":"J Cardiovasc Magn Reson"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.xjon.2023.11.013","article-title":"Adherence to clinical practice guidelines for pulmonary valve intervention after tetralogy of Fallot repair: A nationwide cohort study","volume":"17","author":"Massarella D","year":"2024","unstructured":"Massarella D et al (2024) Adherence to clinical practice guidelines for pulmonary valve intervention after tetralogy of Fallot repair: A nationwide cohort study. JTCVS Open 17:215\u2013228","journal-title":"JTCVS Open"},{"issue":"1","key":"ref21","doi-asserted-by":"crossref","first-page":"e000185","DOI":"10.1136\/openhrt-2014-000185","article-title":"Impact of clinical follow-up and diagnostic testing on intervention for tetralogy of Fallot","volume":"2","author":"House AV","year":"2015","unstructured":"House AV et al (2015) Impact of clinical follow-up and diagnostic testing on intervention for tetralogy of Fallot. Open Heart 2(1):e000185","journal-title":"Open Heart"},{"key":"ref22","author":"Holmes KW","year":"2012","unstructured":"Holmes KW (2012) Timing of pulmonary valve replacement in tetralogy of fallot using cardiac magnetic resonance imaging: an evolving process, in J Am Coll Cardiol. : United States. pp. 1015-7"},{"issue":"11 Suppl","key":"ref23","first-page":"S201","article-title":"Randomized trial of pulmonary valve replacement with and without right ventricular remodeling surgery","volume":"122","author":"Geva T","year":"2010","unstructured":"Geva T et al (2010) Randomized trial of pulmonary valve replacement with and without right ventricular remodeling surgery. Circulation 122(11 Suppl):S201\u2013S208","journal-title":"Circulation"},{"issue":"6","key":"ref24","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/j.amjcard.2004.11.037","article-title":"Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair","volume":"95","author":"Therrien J","year":"2005","unstructured":"Therrien J et al (2005) Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair. Am J Cardiol 95(6):779\u2013782","journal-title":"Am J Cardiol"},{"issue":"5","key":"ref25","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1161\/CIRCULATIONAHA.106.659664","article-title":"Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance","volume":"116","author":"Oosterhof T","year":"2007","unstructured":"Oosterhof T et al (2007) Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance. Circulation 116(5):545\u2013551","journal-title":"Circulation"},{"issue":"24","key":"ref26","doi-asserted-by":"crossref","first-page":"2721","DOI":"10.1093\/eurheartj\/ehi581","article-title":"Remodelling of the right ventricle after early pulmonary valve replacement in children with repaired tetralogy of Fallot: assessment by cardiovascular magnetic resonance","volume":"26","author":"Buechel ER","year":"2005","unstructured":"Buechel ER et al (2005) Remodelling of the right ventricle after early pulmonary valve replacement in children with repaired tetralogy of Fallot: assessment by cardiovascular magnetic resonance. Eur Heart J 26(24):2721\u20132727","journal-title":"Eur Heart J"},{"issue":"3","key":"ref27","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1007\/s00247-018-4312-8","article-title":"4-D flow magnetic-resonance-imaging-derived energetic biomarkers are abnormal in children with repaired tetralogy of Fallot and associated with disease severity","volume":"49","author":"Robinson JD","year":"2019","unstructured":"Robinson JD et al (2019) 4-D flow magnetic-resonance-imaging-derived energetic biomarkers are abnormal in children with repaired tetralogy of Fallot and associated with disease severity. Pediatr Radiol 49(3):308\u2013317","journal-title":"Pediatr Radiol"},{"issue":"1","key":"ref28","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1186\/s12968-021-00789-2","article-title":"Moving beyond size: vorticity and energy loss are correlated with right ventricular dysfunction and exercise intolerance in repaired Tetralogy of Fallot","volume":"23","author":"Loke YH","year":"2021","unstructured":"Loke YH et al (2021) Moving beyond size: vorticity and energy loss are correlated with right ventricular dysfunction and exercise intolerance in repaired Tetralogy of Fallot. J Cardiovasc Magn Reson 23(1):98","journal-title":"J Cardiovasc Magn Reson"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"806107","DOI":"10.3389\/fcvm.2021.806107","article-title":"Right Ventricular Flow Vorticity Relationships With Biventricular Shape in Adult Tetralogy of Fallot","volume":"8","author":"Elsayed A","year":"2021","unstructured":"Elsayed A et al (2021) Right Ventricular Flow Vorticity Relationships With Biventricular Shape in Adult Tetralogy of Fallot. Front Cardiovasc Med 8:806107","journal-title":"Front Cardiovasc Med"},{"issue":"4","key":"ref30","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1002\/jmri.25830","article-title":"Turbulent kinetic energy in the right ventricle: Potential MR marker for risk stratification of adults with repaired Tetralogy of Fallot","volume":"47","author":"Fredriksson A","year":"2018","unstructured":"Fredriksson A et al (2018) Turbulent kinetic energy in the right ventricle: Potential MR marker for risk stratification of adults with repaired Tetralogy of Fallot. J Magn Reson Imaging 47(4):1043\u20131053","journal-title":"J Magn Reson Imaging"},{"issue":"5","key":"ref31","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1016\/j.jtcvs.2014.11.085","article-title":"Ventricular kinetic energy may provide a novel noninvasive way to assess ventricular performance in patients with repaired tetralogy of Fallot","volume":"149","author":"Jeong D","year":"2015","unstructured":"Jeong D et al (2015) Ventricular kinetic energy may provide a novel noninvasive way to assess ventricular performance in patients with repaired tetralogy of Fallot. J Thorac Cardiovasc Surg 149(5):1339\u20131347","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"10","key":"ref32","doi-asserted-by":"crossref","first-page":"4066","DOI":"10.1007\/s00330-018-5385-3","article-title":"Disturbed left and right ventricular kinetic energy in patients with repaired tetralogy of Fallot: pathophysiological insights using 4D-flow MRI","volume":"28","author":"Sj\u00f6berg P","year":"2018","unstructured":"Sj\u00f6berg P et al (2018) Disturbed left and right ventricular kinetic energy in patients with repaired tetralogy of Fallot: pathophysiological insights using 4D-flow MRI. Eur Radiol 28(10):4066\u20134076","journal-title":"Eur Radiol"},{"issue":"6","key":"ref33","doi-asserted-by":"crossref","first-page":"H1691","DOI":"10.1152\/ajpheart.00330.2018","article-title":"Altered biventricular hemodynamic forces in patients with repaired tetralogy of Fallot and right ventricular volume overload because of pulmonary regurgitation","volume":"315","author":"Sj\u00f6berg P","year":"2018","unstructured":"Sj\u00f6berg P et al (2018) Altered biventricular hemodynamic forces in patients with repaired tetralogy of Fallot and right ventricular volume overload because of pulmonary regurgitation. Am J Physiol Heart Circ Physiol 315(6):H1691\u2013h1702","journal-title":"Am J Physiol Heart Circ Physiol"},{"issue":"1","key":"ref34","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1532-429X-14-16","article-title":"4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot","volume":"14","author":"Fran\u00e7ois CJ","year":"2012","unstructured":"Fran\u00e7ois CJ et al (2012) 4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot. J Cardiovasc Magn Reson 14(1):16","journal-title":"J Cardiovasc Magn Reson"},{"issue":"8","key":"ref35","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1007\/s00330-011-2108-4","article-title":"4D-MR flow analysis in patients after repair for tetralogy of Fallot","volume":"21","author":"Geiger J","year":"2011","unstructured":"Geiger J et al (2011) 4D-MR flow analysis in patients after repair for tetralogy of Fallot. Eur Radiol 21(8):1651\u20131657","journal-title":"Eur Radiol"},{"issue":"2","key":"ref36","doi-asserted-by":"crossref","first-page":"253","DOI":"10.2463\/mrms.e.2022-1000","article-title":"Why 4D Flow MRI? Real Advantages","volume":"21","author":"Takehara Y","year":"2022","unstructured":"Takehara Y, Sekine T, Obata T (2022) Why 4D Flow MRI? Real Advantages. Magn Reson Med Sci 21(2):253\u2013256","journal-title":"Magn Reson Med Sci"}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/www.researchsquare.com\/article\/rs-6280623\/v1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.researchsquare.com\/article\/rs-6280623\/v1.html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T16:01:12Z","timestamp":1768233672000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchsquare.com\/article\/rs-6280623\/v1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,16]]},"references-count":36,"URL":"https:\/\/doi.org\/10.21203\/rs.3.rs-6280623\/v1","relation":{"is-preprint-of":[{"id-type":"doi","id":"10.1007\/s00246-025-04146-3","asserted-by":"subject"}]},"subject":[],"published":{"date-parts":[[2025,4,16]]},"subtype":"preprint"}}