{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T05:38:24Z","timestamp":1777095504816,"version":"3.51.4"},"reference-count":23,"publisher":"University of Tokushima Faculty of Medicine","issue":"1.2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Med. Invest."],"published-print":{"date-parts":[[2026]]},"DOI":"10.2152\/jmi.73.217","type":"journal-article","created":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T22:10:16Z","timestamp":1776895816000},"page":"217-221","source":"Crossref","is-referenced-by-count":0,"title":["Impact of surgeon experience on the effectiveness of patient-specific instrumentation in reverse shoulder arthroplasty"],"prefix":"10.2152","volume":"73","author":[{"given":"Jun","family":"Kawamata","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, NHO Kochi National Hospital, Kochi, Japan"},{"name":"Department of Orthopedics, Tokushima University, Tokushima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shoji","family":"Fukuta","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, NHO Kochi National Hospital, Kochi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Nakai","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Tokushima University, Tokushima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Kano","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, NHO Kochi National Hospital, Kochi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsutoshi","family":"Miyatake","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Yoshinogawa Medical Center, Tokushima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Sairyo","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Tokushima University, Tokushima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"925","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"1. Guti\u00e9rrez S, Greiwe RM, Frankle MA, Siegal S, Lee 3rd WE:Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg 16(3 Suppl):S9-S12, 2007. doi:10.1016\/j.jse.2005.11.008","DOI":"10.1016\/j.jse.2005.11.008"},{"key":"2","doi-asserted-by":"publisher","unstructured":"2. Gutierrez S, Walker M, Willis M, Pupello DR, Frankle MA:Effects of tilt and glenosphere eccentricity on baseplate\/bone interface forces in a computational model, validated by a mechanical model, of reverse shoulder arthroplasty. J Shoulder Elbow Surg 20:732-739, 2011. doi:10.1016\/j.jse.2010.10.035","DOI":"10.1016\/j.jse.2010.10.035"},{"key":"3","doi-asserted-by":"publisher","unstructured":"3. Gulotta LV, Choi D, Marinello P, Knutson Z, Lipman J, Wright T, Cordasco FA, Craig EV, Warren RF:Humeral component retroversion in reverse total shoulder arthroplasty:a biomechanical study. J Shoulder Elbow Surg 21:1121-1127, 2012. doi:10.1016\/j.jse.2011.07.027","DOI":"10.1016\/j.jse.2011.07.027"},{"key":"4","doi-asserted-by":"publisher","unstructured":"4. Ladermann A, Denard PJ, Boileau P, Farron A, Deransart P, Walch G:What is the best glenoid configuration in onlay reverse shoulder arthroplasty? Int Orthop 42:1339-1346, 2018. doi:10.1007\/s00264-018-3850-x","DOI":"10.1007\/s00264-018-3850-x"},{"key":"5","doi-asserted-by":"publisher","unstructured":"5. Ladermann A, Gueorguiev B, Charbonnier C, Stimec BV, Fasel JHD, Zderic I, Hagen J, Walch G:Scapular notching on kinematic simulated range of motion after reverse shoulder arthroplasty is not the result of impingement in adduction. Medicine (Baltimore) 94:e1615, 2015. doi:10.1097\/MD.0000000000001615","DOI":"10.1097\/MD.0000000000001615"},{"key":"6","doi-asserted-by":"publisher","unstructured":"6. Cunningham G, Borgonovo AR, Rivera M, Brandariz R:Navigation increases the accuracy of glenoid component implantation in reverse total shoulder arthroplasty in shoulders with severe glenoid wear:a comparative cohort study. JSES Int 9:492-500, 2024. doi:10.1016\/j.jseint.2024.11.009","DOI":"10.1016\/j.jseint.2024.11.009"},{"key":"7","doi-asserted-by":"publisher","unstructured":"7. Kim JS, Kim SC, Park JH, Kim HG, Kim DH, Jung HS, Lee SM, Yoo JC:Short-term clinical and radiologic outcomes of reverse total shoulder arthroplasty with navigation system in the Asian population:a retrospective comparative study. JSES Int 9:422-430, 2024. doi:10.1016\/j.jseint.2024.09.025","DOI":"10.1016\/j.jseint.2024.09.025"},{"key":"8","doi-asserted-by":"publisher","unstructured":"8. Dallalana RJ, McMahon RA, East B, Geraghty L:Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty. Int J Shoulder Surg 10:59e66, 2016. doi:10.4103\/0973-6042.180717","DOI":"10.4103\/0973-6042.180717"},{"key":"9","doi-asserted-by":"publisher","unstructured":"9. Iannotti J, Baker J, Rodriguez E, Brems J, Ricchetti E, Mesiha M, Bryan J:Three-dimensional preoperative planning software and a novel information transfer technology improve glenoid component positioning. J Bone Joint Surg Am 96:e71, 2014. doi:10.2106\/jbjs.l.01346","DOI":"10.2106\/JBJS.L.01346"},{"key":"10","doi-asserted-by":"publisher","unstructured":"10. Iannotti JP, Weiner S, Rodriguez E, Subhas N, Patterson TE, Jun BJ, Ricchetti ET:Three-dimensional imaging and templating improve glenoid implant positioning. J Bone Joint Surg Am 97:651e8, 2015. doi:10.2106\/jbjs.n.00493","DOI":"10.2106\/JBJS.N.00493"},{"key":"11","doi-asserted-by":"publisher","unstructured":"11. Throckmorton TW, Gulotta LV, Bonnarens FO, Wright SA, Hartzell JL, Rozzi WB, Hurst JM, Frostick SP, Sperling JW:Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty:a multi-surgeon study in 70 arthritic cadaver specimens. J Shoulder Elbow Surg 24:965-971, 2015. doi:10.1016\/j.jse.2014.10.013","DOI":"10.1016\/j.jse.2014.10.013"},{"key":"12","doi-asserted-by":"publisher","unstructured":"12. Hamada K, Fukuda H, Mikasa M, Kobayashi Y:Roentgenographic findings in massive rotator cuff tears. A long-term observation. Clin Orthop Relat Res (254):92-96, 1990. doi:10.1097\/00003086-199005000-00014","DOI":"10.1097\/00003086-199005000-00014"},{"key":"13","doi-asserted-by":"publisher","unstructured":"13. Walch G, Vezeridis PS, Boileau P, Deransart P, Chaoui J:Three-dimensional planning and use of patient-specific guides improve glenoid component position:an in vitro study. J Shoulder Elbow Surg 24:302e9, 2015. doi:10.1016\/j.jse.2014.05.029","DOI":"10.1016\/j.jse.2014.05.029"},{"key":"14","doi-asserted-by":"publisher","unstructured":"14. Hayes A, Mackie KE, Wang A:Novel 3-D computer tomography evaluation of glenoid implant placement in reverse shoulder arthroplasty. Biomed J Sci Tech Res 14:10813-10816, 2019. doi:10.26717\/BJSTR.2019.14.002592","DOI":"10.26717\/BJSTR.2019.14.002592"},{"key":"15","doi-asserted-by":"publisher","unstructured":"15. Cabarcas BC, Cvetanovich GL, Gowd AK, Liu JN, Manderle BJ, Verma NN:Accuracy of patient-specific instrumentation in shoulder arthroplasty:a systematic review and meta-analysis. JSES Open Access 3:117-129, 2019. doi:10.1016\/j.jses.2019.07.002.","DOI":"10.1016\/j.jses.2019.07.002"},{"key":"16","doi-asserted-by":"publisher","unstructured":"16. Lau SC, Keith PPA:Patient-specific instrumentation for total shoulder arthroplasty:not as accurate as it would seem. J Shoulder Elbow Surg 27:90e5, 2018. doi:10.1016\/j.jse.2017.07.004","DOI":"10.1016\/j.jse.2017.07.004"},{"key":"17","doi-asserted-by":"publisher","unstructured":"17. Levy JC, Everding NG, Frankle MA, Keppler LJ:Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty. J Shoulder Elbow Surg 23:1563e7, 2014. doi:10.1016\/j.jse.2014.01.051","DOI":"10.1016\/j.jse.2014.01.051"},{"key":"18","unstructured":"18. Pietrzak WS:Shoulder alignment obtained with the Signature Glenoid Guide System:a cadaver study. Warsaw, IN: Biomet Orthopaedics. p. 1-3, 2013"},{"key":"19","doi-asserted-by":"publisher","unstructured":"19. Trouilloud P, Gonzalvez M, Martz P, Charles H, Handelberg F, Nyffeler RW, Baulot E:Duocentric(R) reversed shoulder prosthesis and Personal Fit(R) templates:innovative strategies to optimize prosthesis positioning and prevent scapular notching. Eur J Orthop Surg Traumatol 24:483e95, 2014. doi:10.1007\/s00590-013-1213-2","DOI":"10.1007\/s00590-013-1213-2"},{"key":"20","doi-asserted-by":"publisher","unstructured":"20. Boileau P, Gauci MO, Wagner ER, Clowez G, Chaoui J, Chelli M, Walch G:The reverse shoulder arthroplasty angle:a new measurement of glenoid inclination for reverse shoulder arthroplasty J Shoulder Elbow Surg 28(7):1281-1290, 2019. doi:10.1016\/j.jse.2018.11.074.","DOI":"10.1016\/j.jse.2018.11.074"},{"key":"21","doi-asserted-by":"publisher","unstructured":"21. Parys MV, Alkiar O, Naidoo N, Tongel AV, Wilde LD:Three-dimensional evaluation of scapular morphology in primary glenohumeral arthritis, rotator cuff arthropathy, and asymptomatic shoulders. J Shoulder Elbow Surg 30(8):1803-1810, 2021. doi:10.1016\/j.jse.2020.10.027.","DOI":"10.1016\/j.jse.2020.10.027"},{"key":"22","doi-asserted-by":"publisher","unstructured":"22. Cullen MM, Cochrane NH, Wu CJ, Wellman SS, Bolognesi MP, Seyler TM, Ryan SP:Surgeon experience may predict failure after revision total hip arthroplasty for periprosthetic fracture. J Arthroplasty, 2025. Online ahead of print. doi:10.1016\/j.arth.2025.01.046","DOI":"10.1016\/j.arth.2025.01.046"},{"key":"23","doi-asserted-by":"publisher","unstructured":"23. Kraus KR, Harris AC, Ziemba-Davis M, Buller LT, Meneghini RM:Fellowship-trained surgeons experience a learning curve performing revision total joint arthroplasty. J Arthroplasty 40:28-33, 2025. doi:10.1016\/j.arth.2024.08.011","DOI":"10.1016\/j.arth.2024.08.011"}],"container-title":["The Journal of Medical Investigation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jmi\/73\/1.2\/73_217\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T04:57:22Z","timestamp":1777093042000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jmi\/73\/1.2\/73_217\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":23,"journal-issue":{"issue":"1.2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2152\/jmi.73.217","relation":{},"ISSN":["1343-1420","1349-6867"],"issn-type":[{"value":"1343-1420","type":"print"},{"value":"1349-6867","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]}}}