{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T17:20:20Z","timestamp":1783704020967,"version":"3.55.0"},"reference-count":27,"publisher":"IWA Publishing","issue":"9","license":[{"start":{"date-parts":[[2022,8,16]],"date-time":"2022-08-16T00:00:00Z","timestamp":1660608000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["iwaponline.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Legionnaires' disease is a serious health risk among the elderly. Water systems in care homes are therefore of particular interest. We investigated the levels of culturable Legionella in the hot water systems in care homes in two Danish municipalities. Two hundred and sixty-eight water samples from 98 care homes were evaluated. Contents of culturable Legionella counts were calculated, and correlations between temperature and colony-forming units (CFU\/L) were analysed. Seventy-seven and 81%, respectively, of the care homes were colonised with Legionella in the two municipalities. Most care homes had less than 1,000 CFU\/L, but 13 and 16% had more than 10,000 CFU\/L. When including first flush samples, 27% of the care homes in Municipality 1 had Legionella levels above 10,000 CFU\/L. Temperatures of \u226550 \u00b0C in Municipality 1 and \u226555 \u00b0C in Municipality 2 correlated with low levels of Legionella. The content of Legionella colonies was significantly higher in care homes in Municipality 1. However, a significantly higher proportion of taps in Municipality 2 had Legionella colonies. In conclusion, temperatures should be raised to 55 \u00b0C to avoid high Legionella levels. Test procedures should be evaluated, and the regular use of taps and routine testing for Legionella should be taken into consideration.<\/jats:p>","DOI":"10.2166\/wh.2022.116","type":"journal-article","created":{"date-parts":[[2022,8,16]],"date-time":"2022-08-16T11:50:12Z","timestamp":1660650612000},"page":"1393-1404","update-policy":"https:\/\/doi.org\/10.2166\/iwapcrossmarkpolicypage","source":"Crossref","is-referenced-by-count":5,"title":["<i>Legionella<\/i> colonisation in hot water systems in care homes from two Danish municipalities"],"prefix":"10.2166","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4705-5143","authenticated-orcid":false,"given":"Niss Skov","family":"Nielsen","sequence":"first","affiliation":[{"name":"a Danish Building Research Institute (Build), Division of Sustainability, Energy and Indoor Environment in Buildings, Aalborg University, A.C. Meyers Vaenge 15, 2450 Copenhagen SV, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00f8ren Anker","family":"Uldum","sequence":"additional","affiliation":[{"name":"b Department of Bacteria, Parasites and Fungi, Statens Serum Institut (SSI), Artillerivej 5, 2300 Copenhagen S, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"945","published-online":{"date-parts":[[2022,8,16]]},"reference":[{"key":"2023101915251742500_JWH-D-22-00116C1","doi-asserted-by":"crossref","first-page":"21660","DOI":"10.3390\/ijms141121660","article-title":"Biofilms: the stronghold of Legionella pneumophila","volume":"14","year":"2013","journal-title":"Int. J. Mol. Sci."},{"key":"2023101915251742500_JWH-D-22-00116C2","unstructured":"Danish Building Research Institute (Build)\n          1986\n          Nye muligheder for udformning af vand og afl\u00f8bsinstallationer (New Possibilities for Design of Water and Drainage Installations). SBI Report no. 178."},{"key":"2023101915251742500_JWH-D-22-00116C3","unstructured":"Danish Building Research Institute (Build)2019Statens Serum Institut (SSI), Danish Technological Institute (DTI), Danish Patient Safety Board (STPS), Danish Transport, Construction and Housing Authority (DTCHA) (2019). Legionalla i danske vandsystemer (Legionella in Danish hot Water Systems). SBI Report No. 2019:10."},{"key":"2023101915251742500_JWH-D-22-00116C4","unstructured":"Danish Technological Institute (DTI)\n          2019\n          Legionella \u2013 installationsprincipper og bek\u00e6mpelsesmetoder (Legionella, Installation Principles and Prevention Methods). Available from: https:\/\/www.teknologisk.dk\/_\/media\/74890_R%F8rcenter-anvisning%20017.%20Legionella.pdf (accessed 22 April 2022)."},{"key":"2023101915251742500_JWH-D-22-00116C5","unstructured":"Danva\n          2018\n          Vand i tal. Statistik og benchmarking (Water in Numbers. Statistics and Benchmarking). Available from: https:\/\/www.danva.dk\/media\/5002\/2018_vand-i-tal.pdf (accessed 22 April 2022)."},{"issue":"6","key":"2023101915251742500_JWH-D-22-00116C6","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/j.1708-8305.2007.00146.x","article-title":"Colonization of Legionella species in hotel water systems in Turkey","volume":"14","year":"2007","journal-title":"J. Travel Med."},{"key":"2023101915251742500_JWH-D-22-00116C7","unstructured":"European Centre for Disease Prevention and Control (ECDC)\n          2020\n          Survival Atlas of Infectious Diseases. Available from: https:\/\/atlas.ecdc.europa.eu\/public\/index.aspx (accessed 22 April 2022)."},{"key":"2023101915251742500_JWH-D-22-00116C8","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1007\/s10096-002-0820-3","article-title":"Pan-European study on culture-proven Legionnaires' disease: distribution of Legionella pneumophila serogroups and monoclonal subgroups","volume":"21","year":"2002","journal-title":"Eur. J. Clin. Microbiol. Infect. Dis."},{"issue":"11","key":"2023101915251742500_JWH-D-22-00116C9","doi-asserted-by":"crossref","first-page":"1770","DOI":"10.3390\/microorganisms8111770","article-title":"Evaluation of recommended water sample collection methods and the impact of holding time on Legionella recovery and variability from healthcare building water systems","volume":"8","year":"2020","journal-title":"Microorganisms"},{"issue":"6","key":"2023101915251742500_JWH-D-22-00116C10","first-page":"571","article-title":"Prevalence of Legionella species in water resources of Iran: a systematic review and meta-analysis","volume":"43","year":"2018","journal-title":"Iran. J. Med. Sci."},{"key":"2023101915251742500_JWH-D-22-00116C11","unstructured":"Kragh\n            J.\n           & BuhlL.2021Identifikation af trends i forhold til vand-og varmeforsyning og installationer (Identification of Trends in Relation to Water and Heat Supply and Installations). Indenrigs-og Boligudvalget 2020\u201321. BOU Alm.del - Bilag 174: Bilag 4 - Identifikation af trends i forhold til vand- og varmeforsyning og installationer. (accessed 22 April 2022)."},{"key":"2023101915251742500_JWH-D-22-00116C12","unstructured":"Lee\n            S.\n          , CrespiS., KuznetsovJ., LeeJ., de JongB., RicciM. L., van der LugtW., VeschettiE. & WalkerJ. T.2017European Technical Guidelines for the Prevention, Control and Investigation of Infections Caused by Legionella Species. Available from: https:\/\/ecdc.europa.eu\/en\/publications-data\/european-technical-guidelines-prevention-control-and-investigation-infections (accessed 22 April 2022)."},{"issue":"2","key":"2023101915251742500_JWH-D-22-00116C13","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/j.1365-2672.2004.02458.x","article-title":"Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems","volume":"98","year":"2005","journal-title":"J. Appl. Microbiol."},{"key":"2023101915251742500_JWH-D-22-00116C14","unstructured":"Milj\u00f8styrelsen\n          MST 2015\n          Milj\u00f8styrelsens Referencelaboratorium for Kemiske og Mikrobiologiske Milj\u00f8m\u00e5linger, Metodedatablad MM0009. Legionella i bassinvand og drikkevand (Legionella in Pool Water and Drinking Water). V01a\/16.09.2015."},{"issue":"1","key":"2023101915251742500_JWH-D-22-00116C15","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1128\/AEM.72.1.378-383.2006","article-title":"Introduction of monochloramine into a municipal water system: impact on colonization of buildings by Legionella spp","volume":"72","year":"2006","journal-title":"Appl. Environ. Microbiol."},{"key":"2023101915251742500_JWH-D-22-00116C16","unstructured":"Nielsen\n            N. S.\n           & AggerholmS.2022Water Sampling and Legionellae in Danish Hot Water Systems \u2013 A Short Review. Danish Building Research Institute (Build) (Report: 10-2022). Available from: https:\/\/build.dk\/Assets\/Water-Sampling-and-Legionellae-in-Danish-hot-water-systems\/Water-Sampling-and-Legionella-in-Danish-hot-water-systems.pdf (accessed 22 April 2022)."},{"issue":"2","key":"2023101915251742500_JWH-D-22-00116C17","doi-asserted-by":"crossref","first-page":"195","DOI":"10.5604\/12321966.1152064","article-title":"Prevalence of Legionella pneumophila in water distribution systems in hospitals and public buildings of the Lublin region of eastern Poland","volume":"22","year":"2015","journal-title":"Ann. Agric. Environ. Med."},{"key":"2023101915251742500_JWH-D-22-00116C18","volume-title":"Legionella i varmt brugsvand. Overv\u00e5gning, udredning og forebyggelse af Legion\u00e6rsygdom (Legionella in Hot Water. Surveillance, Investigation and Prevention of Legionnaires' Disease)","author":"Statens Serum Institut","year":"2000","edition":"1st edn"},{"key":"2023101915251742500_JWH-D-22-00116C19","unstructured":"Statens Serum Institut (SSI)\n          2019\n          Legionnaires' Disease, Annual Report 2019. Available from: https:\/\/en.ssi.dk\/surveillance-and-preparedness\/surveillance-in-denmark\/annual-reports-on-disease-incidence\/legionnaires-disease-2019 (accessed 22 April 2022)."},{"key":"2023101915251742500_JWH-D-22-00116C20","unstructured":"Statens Serum Institut (SSI)\n          2020\n          Legionnaires' Disease, Annual Report 2020. Available from: https:\/\/en.ssi.dk\/surveillance-and-preparedness\/surveillance-in-denmark\/annual-reports-on-disease-incidence\/Legionella-2020-annual-report (accessed 22 April 2022)."},{"key":"2023101915251742500_JWH-D-22-00116C21","unstructured":"Statens Serum Institut (SSI)\n          2021\n          Projekt 2 \u2013 Unders\u00f8gelse af vandpr\u00f8ver som indikator for legionellatilf\u00e6lde og typer. Indenrigs-og Boligudvalget 2020\u201321. BOU Alm.del-Bilag 174. BOU Alm.del - Bilag 174: Bilag 2 - Unders\u00f8gelse af vandpr\u00f8ver som indikator for legionellatilf\u00e6lde og typer (ft.dk). (accessed 22 April 2022)."},{"issue":"2","key":"2023101915251742500_JWH-D-22-00116C22","first-page":"295","article-title":"Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. II. Examination of native samples from various sources","volume":"19","year":"2012","journal-title":"Ann. Agric. Environ. Med."},{"issue":"11","key":"2023101915251742500_JWH-D-22-00116C23","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.3390\/ijerph14111296","article-title":"Presence of Legionella spp. in hot water networks of different Italian residential buildings: a three-year survey","volume":"14","year":"2017","journal-title":"Int. J. Environ. Res. Public Health"},{"issue":"5","key":"2023101915251742500_JWH-D-22-00116C24","doi-asserted-by":"crossref","first-page":"2530","DOI":"10.3390\/ijerph19052530","article-title":"A tale of four Danish cities: Legionella pneumophila diversity in domestic hot water and spatial variation in disease incidence","volume":"19","year":"2022","journal-title":"Int. J. Environ. Res. Public Health"},{"issue":"1","key":"2023101915251742500_JWH-D-22-00116C25","doi-asserted-by":"crossref","first-page":"65","DOI":"10.3109\/1040841X.2014.885930","article-title":"Legionella detection by culture and qPCR: comparing apples and oranges","volume":"42","year":"2016","journal-title":"Crit. Rev. Microbiol."},{"key":"2023101915251742500_JWH-D-22-00116C26","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.3389\/fmicb.2017.01330","article-title":"Legionella persistence in manufactured water systems: pasteurization potentially selecting for thermal tolerance","volume":"8","year":"2017","journal-title":"Front. Microbiol."},{"key":"2023101915251742500_JWH-D-22-00116C27","unstructured":"World Health Organization (WHO)\n          2017\n          Recommendations \u2013 Support to the Revision of Annex I Council Directive 98\/83\/EC on the Quality of Water Intended for Human Consumption (Drinking Water Directive). 20171215_EC_project_report_final_corrected.pdf (europa.eu)."}],"updated-by":[{"DOI":"10.2166\/wh.2023.104","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T00:00:00Z","timestamp":1697673600000}}],"container-title":["Journal of Water and Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/iwaponline.com\/jwh\/article-pdf\/20\/9\/1393\/1309617\/jwh0201393.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iwaponline.com\/jwh\/article-pdf\/20\/9\/1393\/1309617\/jwh0201393.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T15:26:05Z","timestamp":1697729165000},"score":1,"resource":{"primary":{"URL":"https:\/\/iwaponline.com\/jwh\/article\/20\/9\/1393\/90223\/Legionella-colonisation-in-hot-water-systems-in"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,16]]},"references-count":27,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2022,8,16]]},"published-print":{"date-parts":[[2022,9,1]]}},"URL":"https:\/\/doi.org\/10.2166\/wh.2022.116","relation":{"correction":[{"id-type":"doi","id":"10.2166\/wh.2023.104","asserted-by":"object"}]},"ISSN":["1477-8920","1996-7829"],"issn-type":[{"value":"1477-8920","type":"print"},{"value":"1996-7829","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,16]]}}}