{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T07:09:25Z","timestamp":1769238565614,"version":"3.49.0"},"reference-count":47,"publisher":"IWA Publishing","issue":"7","license":[{"start":{"date-parts":[[2025,6,10]],"date-time":"2025-06-10T00:00:00Z","timestamp":1749513600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["iwaponline.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n               <jats:p\/>\n               <jats:p>Legionella spp. are Gram-negative bacteria present in natural and engineered water systems that can cause legionellosis (Legionnaires' disease and Pontiac fever). When present in biofilms of healthcare facilities, they are a likely source of legionellosis for immunocompromised patients. The objective of this study was to evaluate an electrochemical water disinfection system to produce and dose hypochlorous acid (HOCl) to reduce this risk in a hospital with systemic Legionella spp. contamination. Furthermore, Legionella spp. colony counts were compared to quantitative polymerase chain reaction (qPCR) results. Before and after implementing the disinfection system, tap water and pipe biofilms were analysed for microbial contamination. Post-implementation monitoring continued for over six months, assessing microbial quality using heterotrophic colony counts, Legionella serotyping, and qPCR targeting total bacteria (16S rRNA) and Legionella spp. By the third sampling event (22 days post-commissioning), water quality consistently improved, with no culture-positive Legionella counts observed thereafter. qPCR analysis confirmed these results, proving more sensitive and reliable than traditional methods. The qPCR assays for Legionella spp. and bacterial 16S rRNA were also cost-effective for system optimisation and diagnostics.<\/jats:p>","DOI":"10.2166\/wh.2025.395","type":"journal-article","created":{"date-parts":[[2025,6,10]],"date-time":"2025-06-10T13:33:21Z","timestamp":1749562401000},"page":"877-893","update-policy":"https:\/\/doi.org\/10.2166\/iwapcrossmarkpolicypage","source":"Crossref","is-referenced-by-count":1,"title":["Mitigating <i>Legionella<\/i> spp. risk in an Australian healthcare facility using on-site electrochemical water disinfection"],"prefix":"10.2166","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6478-6220","authenticated-orcid":false,"given":"Sopheak","family":"Hem","sequence":"first","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"},{"name":"b CRC SAAFE (Cooperative Research Centre for Solving Antimicrobial Resistance in Agribusiness, Food, and Environments) Cooperative Research Centre for Solving Antimicrobial Resistance in Agribusiness, Food, and Environments (CRC SAAFE), Adelaide, South Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3301-0470","authenticated-orcid":false,"given":"Barbara","family":"Drigo","sequence":"additional","affiliation":[{"name":"c UniSA STEM, University of South Australia, Adelaide, SA, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2048-8192","authenticated-orcid":false,"given":"Sotirios","family":"Vasileiadis","sequence":"additional","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"},{"name":"d Department of Biochemistry and Biotechnology, Laboratory of Plant and Environmental Biotechnology, University of Thessaly, Larissa, Viopolis 41500, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6490-9948","authenticated-orcid":false,"given":"Gianluca","family":"Brunetti","sequence":"additional","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"},{"name":"e Department of Agricultural, Food and Environmental Sciences, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4999-4416","authenticated-orcid":false,"given":"Euan","family":"Smith","sequence":"additional","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergio","family":"Ferro","sequence":"additional","affiliation":[{"name":"f Ecas4 Australia Pty Ltd, 8\/1 London Road, Mile End South, South Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3384-0375","authenticated-orcid":false,"given":"Enzo","family":"Lombi","sequence":"additional","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3853-0096","authenticated-orcid":false,"given":"Nicholas J.","family":"Ashbolt","sequence":"additional","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"},{"name":"b CRC SAAFE (Cooperative Research Centre for Solving Antimicrobial Resistance in Agribusiness, Food, and Environments) Cooperative Research Centre for Solving Antimicrobial Resistance in Agribusiness, Food, and Environments (CRC SAAFE), Adelaide, South Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6465-2233","authenticated-orcid":false,"given":"Erica","family":"Donner","sequence":"additional","affiliation":[{"name":"a Future Industries Institute, University of South Australia, Mawson Lakes, South Australia, Australia"},{"name":"b CRC SAAFE (Cooperative Research Centre for Solving Antimicrobial Resistance in Agribusiness, Food, and Environments) Cooperative Research Centre for Solving Antimicrobial Resistance in Agribusiness, Food, and Environments (CRC SAAFE), Adelaide, South Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"945","published-online":{"date-parts":[[2025,6,10]]},"reference":[{"key":"key-10.2166\/wh.2025.395-1","doi-asserted-by":"publisher","DOI":"10.3389\/fcimb.2023.1200478"},{"key":"key-10.2166\/wh.2025.395-2","doi-asserted-by":"publisher","DOI":"10.2166\/washdev.2020.151"},{"key":"key-10.2166\/wh.2025.395-3"},{"key":"key-10.2166\/wh.2025.395-4","doi-asserted-by":"publisher","DOI":"10.1016\/j.nmni.2021.100948"},{"key":"key-10.2166\/wh.2025.395-5","doi-asserted-by":"publisher","DOI":"10.1021\/acsestwater.4c00812"},{"key":"key-10.2166\/wh.2025.395-6","doi-asserted-by":"publisher","DOI":"10.1111\/1574-6941.12294"},{"key":"key-10.2166\/wh.2025.395-7","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.3869"},{"key":"key-10.2166\/wh.2025.395-8","doi-asserted-by":"publisher","DOI":"10.1016\/S1473-3099(18)30605-4"},{"key":"key-10.2166\/wh.2025.395-9","doi-asserted-by":"publisher","DOI":"10.3201\/eid2701.190676"},{"key":"key-10.2166\/wh.2025.395-10","doi-asserted-by":"publisher","DOI":"10.5942\/jawwa.2014.106.0002"},{"key":"key-10.2166\/wh.2025.395-11","doi-asserted-by":"publisher","DOI":"10.1111\/j.1574-6941.2006.00190.x"},{"key":"key-10.2166\/wh.2025.395-12","doi-asserted-by":"publisher","DOI":"10.3201\/eid2511.190522"},{"key":"key-10.2166\/wh.2025.395-13","volume-title":"An Effective and Natural Approach to Improving Environmental Health and Reducing Food Spoilage [WWW Document]","author":"ECAS4 Australia","year":"2019"},{"key":"key-10.2166\/wh.2025.395-14"},{"key":"key-10.2166\/wh.2025.395-15","volume-title":"European Technical Guidelines for the Prevention, Control and Investigation of Infections Caused by Legionella Species | Safety and Health at Work EU-OSHA [WWW Document]","author":"EU-OSHA","year":"2021"},{"key":"key-10.2166\/wh.2025.395-16","doi-asserted-by":"publisher","DOI":"10.1128\/msystems.00217-17"},{"key":"key-10.2166\/wh.2025.395-17","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2024.173651"},{"key":"key-10.2166\/wh.2025.395-18","volume-title":"Legionella and Water Delivery Systems [WWW Document]","author":"Health-Vic","year":"2024"},{"key":"key-10.2166\/wh.2025.395-19","doi-asserted-by":"publisher","DOI":"10.1039\/D1EW00397F"},{"key":"key-10.2166\/wh.2025.395-20","doi-asserted-by":"publisher","DOI":"10.1007\/s12393-021-09278-9"},{"key":"key-10.2166\/wh.2025.395-21","article-title":"Relationships between oxidation-reduction potential, oxidant, and pH in drinking water","author":"James","year":"2004"},{"key":"key-10.2166\/wh.2025.395-22","doi-asserted-by":"publisher","DOI":"10.1016\/j.foar.2019.10.001"},{"key":"key-10.2166\/wh.2025.395-23","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0227285"},{"key":"key-10.2166\/wh.2025.395-24","doi-asserted-by":"publisher","DOI":"10.3390\/microorganisms12050916"},{"key":"key-10.2166\/wh.2025.395-25","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2672.2011.04957.x"},{"key":"key-10.2166\/wh.2025.395-26","doi-asserted-by":"publisher","DOI":"10.1016\/j.tim.2018.06.002"},{"key":"key-10.2166\/wh.2025.395-27","doi-asserted-by":"publisher","DOI":"10.1021\/es506118e"},{"key":"key-10.2166\/wh.2025.395-28","doi-asserted-by":"publisher","DOI":"10.1038\/s41522-024-00573-x"},{"key":"key-10.2166\/wh.2025.395-29","doi-asserted-by":"publisher","DOI":"10.3390\/microorganisms8091452"},{"key":"key-10.2166\/wh.2025.395-30","volume-title":"Management of Legionella in Water Systems [WWW Document]","author":"NAS","year":"2020"},{"key":"key-10.2166\/wh.2025.395-31","volume-title":"Australian Drinking Water Guidelines | NHMRC [WWW Document]","author":"NHMRC","year":"2023"},{"key":"key-10.2166\/wh.2025.395-32","doi-asserted-by":"publisher","DOI":"10.3389\/fmicb.2023.1094877"},{"key":"key-10.2166\/wh.2025.395-33","doi-asserted-by":"publisher","DOI":"10.1016\/j.watres.2024.121273"},{"key":"key-10.2166\/wh.2025.395-34","doi-asserted-by":"publisher","DOI":"10.1039\/C6EW00030D"},{"key":"key-10.2166\/wh.2025.395-35","doi-asserted-by":"publisher","DOI":"10.3390\/microorganisms9030577"},{"key":"key-10.2166\/wh.2025.395-36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheh.2019.04.007"},{"key":"key-10.2166\/wh.2025.395-37","doi-asserted-by":"publisher","DOI":"10.3390\/pathogens13070563"},{"key":"key-10.2166\/wh.2025.395-38","doi-asserted-by":"publisher","DOI":"10.3389\/fmicb.2023.1146165"},{"key":"key-10.2166\/wh.2025.395-39","doi-asserted-by":"publisher","DOI":"10.4137\/MBI.S17723"},{"key":"key-10.2166\/wh.2025.395-40","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhazmat.2024.134751"},{"key":"key-10.2166\/wh.2025.395-41","doi-asserted-by":"publisher","DOI":"10.1016\/j.watres.2016.06.010"},{"key":"key-10.2166\/wh.2025.395-42","doi-asserted-by":"publisher","DOI":"10.1111\/1755-0998.13674"},{"key":"key-10.2166\/wh.2025.395-43","doi-asserted-by":"publisher","DOI":"10.3109\/1040841X.2014.885930"},{"key":"key-10.2166\/wh.2025.395-44","volume-title":"Legionellosis [WWW Document]","author":"WHO","year":"2022"},{"key":"key-10.2166\/wh.2025.395-45","doi-asserted-by":"publisher","DOI":"10.1093\/nar\/gkt1209"},{"key":"key-10.2166\/wh.2025.395-46","doi-asserted-by":"publisher","DOI":"10.3389\/fmicb.2021.766364"},{"key":"key-10.2166\/wh.2025.395-47","doi-asserted-by":"publisher","DOI":"10.3389\/fcimb.2023.1137947"}],"container-title":["Journal of Water and Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/iwaponline.com\/jwh\/article-pdf\/23\/7\/877\/1575537\/jwh2025395.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iwaponline.com\/jwh\/article-pdf\/23\/7\/877\/1575537\/jwh2025395.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,31]],"date-time":"2025-07-31T13:10:46Z","timestamp":1753967446000},"score":1,"resource":{"primary":{"URL":"https:\/\/iwaponline.com\/jwh\/article\/23\/7\/877\/108471\/Mitigating-Legionella-spp-risk-in-an-Australian"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,10]]},"references-count":47,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025,6,10]]},"published-print":{"date-parts":[[2025,7,1]]}},"URL":"https:\/\/doi.org\/10.2166\/wh.2025.395","relation":{},"ISSN":["1477-8920","1996-7829"],"issn-type":[{"value":"1477-8920","type":"print"},{"value":"1996-7829","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,10]]}}}