{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T09:54:23Z","timestamp":1782294863052,"version":"3.54.5"},"reference-count":52,"publisher":"IWA Publishing","issue":"11","content-domain":{"domain":["iwaponline.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,6,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Three types of odour abatement systems in sewer networks in Australia were studied for 18 months to determine the removals of different compounds. Six volatile sulfurous compounds and seven volatile organic compounds (VOCs) were further investigated. All types of odour abatement systems exhibited good removal of hydrogen sulfide with the biotrickling filters (BTFs) showing the highest consistent removal. Biofilters outperformed BTFs and activated carbon (AC) filters in the removal of dimethyl mono-, di- and tri-sulfide species at the low inlet concentrations typically found. AC filters exhibited little VOC removal with no compound consistently identified as having a removal greater than 0%. Biofilters outperformed BTFs in VOC removal, yet both had high removal variability.<\/jats:p>","DOI":"10.2166\/wst.2018.223","type":"journal-article","created":{"date-parts":[[2018,5,17]],"date-time":"2018-05-17T12:35:12Z","timestamp":1526560512000},"page":"2657-2667","update-policy":"https:\/\/doi.org\/10.2166\/iwapcrossmarkpolicypage","source":"Crossref","is-referenced-by-count":12,"title":["A comparison of removal performance of volatile organic and sulfurous compounds between odour abatement systems"],"prefix":"10.2166","volume":"77","author":[{"given":"A.","family":"Shammay","sequence":"first","affiliation":[{"name":"School of Civil and Environmental Engineering, UNSW, Sydney, NSW, Australia"},{"name":"Stantec Australia, North Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.","family":"Evanson","sequence":"first","affiliation":[{"name":"Stantec Australia, North Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. M.","family":"Stuetz","sequence":"first","affiliation":[{"name":"School of Civil and Environmental Engineering, UNSW, Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"945","published-online":{"date-parts":[[2018,5,17]]},"reference":[{"key":"2020032811210203100_WST-EM183C1","volume-title":"Remarkably Low Maintenance and Effective Odor Control From Media-Based Odor Control Systems","year":"2004"},{"issue":"3","key":"2020032811210203100_WST-EM183C2","first-page":"57","article-title":"Biofilters make good neighbors","volume":"18","year":"2006","journal-title":"Water Environment & Technology"},{"key":"2020032811210203100_WST-EM183C2a","volume-title":"Minimization of odors and corrosion in collection systems - Phase 1","year":"2007"},{"key":"2020032811210203100_WST-EM183C3","volume-title":"Performance Evaluation of the Phoenix Odor Control System","year":"2004"},{"issue":"17","key":"2020032811210203100_WST-EM183C4","doi-asserted-by":"crossref","first-page":"4346","DOI":"10.1021\/ie020137t","article-title":"Effect of surface characteristics on adsorption of methyl mercaptan on activated carbons","volume":"41","year":"2002","journal-title":"Industrial & Engineering Chemistry Research"},{"issue":"4","key":"2020032811210203100_WST-EM183C5","doi-asserted-by":"crossref","first-page":"442","DOI":"10.2175\/106143006X111871","article-title":"Wastewater analysis for volatile organic sulfides using purge-and-trap with gas chromatography\/mass spectrometry","volume":"79","year":"2007","journal-title":"Water Environment Research"},{"issue":"3","key":"2020032811210203100_WST-EM183C6","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1002\/ep.670180318","article-title":"Evaluation of a two-stage biofilter for treatment of POTW waste air","volume":"18","year":"1999","journal-title":"Environmental Progress"},{"issue":"5","key":"2020032811210203100_WST-EM183C7","doi-asserted-by":"crossref","first-page":"444","DOI":"10.2175\/106143003X141240","article-title":"Odor and volatile organic compound removal from wastewater treatment plant headworks ventilation air using a biofilter","volume":"75","year":"2003","journal-title":"Water Environment Research"},{"key":"2020032811210203100_WST-EM183C8","doi-asserted-by":"crossref","DOI":"10.1007\/978-94-017-0930-9","volume-title":"Bioreactors for Waste Gas Treatment, Chapter 4: Biotrickling Filters","author":"Kennes","year":"2001"},{"issue":"6","key":"2020032811210203100_WST-EM183C9","doi-asserted-by":"crossref","first-page":"557","DOI":"10.2175\/106143002X140369","article-title":"Odor and volatile organic compound treatment by biotrickling filters: pilot-scale studies at hyperion treatment plant","volume":"74","year":"2002","journal-title":"Water Environ. Res."},{"key":"2020032811210203100_WST-EM183C9a","volume-title":"Design challenges in sewer foul air extraction and treatment","year":"2004"},{"issue":"1\u20132","key":"2020032811210203100_WST-EM183C10","first-page":"53","article-title":"Biofiltration of air: a review","volume":"25","year":"2005","journal-title":"Critical Reviews in Biotechnology"},{"issue":"2","key":"2020032811210203100_WST-EM183C11","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1080\/10473289.2003.10466137","article-title":"Degradation of toluene, xylene, and trimethylbenzene vapors by biofiltration: a comparison","volume":"53","year":"2003","journal-title":"Journal of the Air & Waste Management Association"},{"key":"2020032811210203100_WST-EM183C12","volume-title":"Controlling Odor and VOCs with Bioreactors","year":"2001"},{"issue":"5","key":"2020032811210203100_WST-EM183C13","doi-asserted-by":"crossref","first-page":"816","DOI":"10.2175\/106143095X131736","article-title":"Control of volatile organic compound emissions using a compost biofilter","volume":"67","year":"1995","journal-title":"Water Environment Research"},{"key":"2020032811210203100_WST-EM183C14","volume-title":"Biotrickling Filters for POTWs Air Treatment Full-Scale Experience with a Converted Scrubber","year":"2002"},{"key":"2020032811210203100_WST-EM183C15","first-page":"4","volume-title":"Performance Testing of Biofilters in a Cold Climate","year":"1994"},{"key":"2020032811210203100_WST-EM183C16","volume-title":"Los Angeles Selects Bio-Trickling\/Activated Carbon for Collection System Odor Control","year":"2004"},{"issue":"3","key":"2020032811210203100_WST-EM183C17","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/S0043-1354(00)00313-4","article-title":"Odour measurements for sewage treatment works","volume":"35","year":"2001","journal-title":"Water Res."},{"issue":"1\u20133","key":"2020032811210203100_WST-EM183C18","first-page":"164","article-title":"Adsorption of dimethyl sulfide vapors by activated carbons","volume":"322","year":"2008","journal-title":"Colloids and Surfaces A: Physicochemical and Engineering Aspects"},{"issue":"3","key":"2020032811210203100_WST-EM183C19","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1002\/ep.10077","article-title":"Literature review of air pollution control biofilters and biotrickling filters for odor and volatile organic compound removal","volume":"24","year":"2005","journal-title":"Environ. Prog."},{"key":"2020032811210203100_WST-EM183C20","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1002\/jctb.2216","article-title":"Bioprocesses for air pollution control","volume":"84","year":"2009","journal-title":"J. Chem. Technol. Biotechnol."},{"issue":"4","key":"2020032811210203100_WST-EM183C20a","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1061\/(ASCE)0733-9372(1990)116:4(721)","article-title":"Field performance of activated carbon adsorption for sewage air","volume":"116","year":"1990","journal-title":"Journal of Environmental Engineering"},{"key":"2020032811210203100_WST-EM183C21","volume-title":"Trickling Filters Foul Air Characteristics and Treatment with Activated Carbon Media","year":"2014"},{"issue":"0","key":"2020032811210203100_WST-EM183C22","first-page":"38","article-title":"Odor abatement in biotrickling filters: effect of the EBRT on methyl mercaptan and hydrophobic VOCs removal","volume":"109","year":"2012","journal-title":"Bioresource Technology"},{"key":"2020032811210203100_WST-EM183C23","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.bej.2011.09.017","article-title":"Toluene mass transfer characterization in a biotrickling filter","volume":"60","year":"2012","journal-title":"Biochemical Engineering Journal"},{"issue":"3","key":"2020032811210203100_WST-EM183C24","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S1369-703X(00)00064-4","article-title":"Biofiltration as an odour abatement strategy","volume":"5","year":"2000","journal-title":"Biochemical Engineering Journal"},{"issue":"7","key":"2020032811210203100_WST-EM183C25","doi-asserted-by":"crossref","first-page":"594","DOI":"10.2175\/106143014X13975035525267","article-title":"Efficient control of odors and VOC emissions via activated carbon technology","volume":"86","year":"2014","journal-title":"Water Environment Research"},{"key":"2020032811210203100_WST-EM183C26","volume-title":"Comparison of Different Biotrickling Filter Technologies For Treating Air from Wastewater Treatment Facilities","year":"2004"},{"issue":"3","key":"2020032811210203100_WST-EM183C27","doi-asserted-by":"crossref","first-page":"274","DOI":"10.2175\/106143005X41852","article-title":"Formation and biodegradation of toluene in the anaerobic sludge digestion process","volume":"77","year":"2005","journal-title":"Water Environment Research"},{"issue":"5","key":"2020032811210203100_WST-EM183C28","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/j.jenvman.2010.01.006","article-title":"Bioreactors for treatment of VOCs and odours \u2013 A review","volume":"91","year":"2010","journal-title":"Journal of Environmental Management"},{"issue":"18","key":"2020032811210203100_WST-EM183C29","doi-asserted-by":"crossref","first-page":"5129","DOI":"10.1016\/j.watres.2010.06.013","article-title":"Monitoring techniques for odour abatement assessment","volume":"44","year":"2010","journal-title":"Water Research"},{"issue":"10","key":"2020032811210203100_WST-EM183C30","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1080\/03067319.2015.1055471","article-title":"Biological technologies for the treatment of atmospheric pollutants","volume":"95","year":"2015","journal-title":"International Journal of Environmental Analytical Chemistry"},{"key":"2020032811210203100_WST-EM183C31","first-page":"118","volume-title":"Measurement of Odor Threshold by Triangle Odor Bag Method","year":"2003"},{"issue":"2\u20133","key":"2020032811210203100_WST-EM183C32","first-page":"243","article-title":"Odour removal with a trickling filter at a small WWTP strongly influenced by the tourism season","volume":"44","year":"2001","journal-title":"Water Sci. Technol."},{"issue":"6","key":"2020032811210203100_WST-EM183C33","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1002\/jctb.3743","article-title":"Carbon disulfide biofiltration: influence of the accumulation of biodegradation products on biomass development","volume":"87","year":"2012","journal-title":"Journal of Chemical Technology & Biotechnology"},{"key":"2020032811210203100_WST-EM183C34","volume-title":"Hydrogen Sulfide Emissions and its Removal by Biotrickling Filters: an Interesting Feedback from as Samra Waste Water Treatment Plant in Jordan","year":"2011"},{"key":"2020032811210203100_WST-EM183C35","doi-asserted-by":"crossref","first-page":"3866","DOI":"10.1016\/j.jece.2016.08.016","article-title":"Review of odour abatement in sewer networks","volume":"4","year":"2016","journal-title":"Journal of Environmental Chemical Engineering"},{"key":"2020032811210203100_WST-EM183C36","first-page":"277","article-title":"Performance of field based activated carbon systems for odour control","volume":"53","year":"2016","journal-title":"Chemical Engineering Transactions"},{"key":"2020032811210203100_WST-EM183C37","first-page":"77","article-title":"Sewer odour abatement practices \u2013 an Australian survey","volume":"37","year":"2010","journal-title":"Water"},{"key":"2020032811210203100_WST-EM183C38","volume-title":"Sewer Odours: More Than Just Rotten Eggs","year":"2013"},{"key":"2020032811210203100_WST-EM183C39","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.watres.2015.10.020","article-title":"Prioritisation of odorants emitted from sewers using odour activity values","volume":"88","year":"2016","journal-title":"Water Research"},{"issue":"2","key":"2020032811210203100_WST-EM183C40","doi-asserted-by":"crossref","first-page":"04016080","DOI":"10.1061\/(ASCE)EE.1943-7870.0001154","article-title":"Dynamics of volatile sulfur compounds and volatile organic compounds in sewer headspace air","volume":"143","year":"2017","journal-title":"Journal of Environmental Engineering"},{"key":"2020032811210203100_WST-EM183C41","volume-title":"Biofilter Inspection and Testing Program Results in Lower Biofilter O&M Costs and Improves Biofilter Performance","year":"2004"},{"key":"2020032811210203100_WST-EM183C42","volume-title":"Odour Control Unit Standard Specification","author":"SWC (Sydney Water Corporation)","year":"2011"},{"key":"2020032811210203100_WST-EM183C43","first-page":"182","volume-title":"Evaluation of Two Biotechnologies Controlling POTW Air Emissions","year":"1996"},{"key":"2020032811210203100_WST-EM183C44","unstructured":"Wallis, M., Witherspoon, J., Suzuki, S., Card, T. R., Mayer, G. & Chang, D. P. Y.1996A Critical Review of Odor Control Equipment for Toxic Air Emissions Reduction: Final Report. Water Environment Research Foundation, Alexandria, VA."},{"issue":"1","key":"2020032811210203100_WST-EM183C45","doi-asserted-by":"crossref","first-page":"92","DOI":"10.2166\/wst.2013.559","article-title":"Is H2S a suitable process indicator for odour abatement performance of sewer odours?","volume":"69","year":"2014","journal-title":"Water Sci. Technol."},{"issue":"0","key":"2020032811210203100_WST-EM183C46","first-page":"71","article-title":"Determination of VOSCs in sewer headspace air using TD\u2013GC\u2013SCD","volume":"137","year":"2015","journal-title":"Talanta"},{"issue":"3","key":"2020032811210203100_WST-EM183C47","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1002\/ep.670150311","article-title":"Biofiltration of odors, toxics and volatile organic compounds from publicly owned treatment works","volume":"15","year":"1996","journal-title":"Environmental Progress"},{"key":"2020032811210203100_WST-EM183C48","volume-title":"Treatment of Vapor Emissions Generated from an Industrial Wastewater Treatment Plant Using a Full-Scale Biotrickling Filter Reactor","year":"2000"},{"key":"2020032811210203100_WST-EM183C49","volume-title":"Long-Term Odor and VOC Performance Tests on Biofilters","year":"1994"}],"container-title":["Water Science and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/iwaponline.com\/wst\/article-pdf\/77\/11\/2657\/244463\/wst077112657.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/iwaponline.com\/wst\/article-pdf\/77\/11\/2657\/244463\/wst077112657.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,3,28]],"date-time":"2020-03-28T15:29:00Z","timestamp":1585409340000},"score":1,"resource":{"primary":{"URL":"https:\/\/iwaponline.com\/wst\/article\/77\/11\/2657\/39119\/A-comparison-of-removal-performance-of-volatile"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,17]]},"references-count":52,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2018,5,17]]},"published-print":{"date-parts":[[2018,6,26]]}},"URL":"https:\/\/doi.org\/10.2166\/wst.2018.223","relation":{},"ISSN":["0273-1223","1996-9732"],"issn-type":[{"value":"0273-1223","type":"print"},{"value":"1996-9732","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,5,17]]}}}