{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T03:16:31Z","timestamp":1789010191548,"version":"build-2803163510"},"reference-count":23,"publisher":"IWA Publishing","issue":"1","license":[{"start":{"date-parts":[[2023,12,26]],"date-time":"2023-12-26T00:00:00Z","timestamp":1703548800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"National Key R & D Program of the Science and Technology of China","award":["2021YFC3001402-02"],"award-info":[{"award-number":["2021YFC3001402-02"]}]}],"content-domain":{"domain":["iwaponline.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The volume capture ratio of annual rainfall (VCRAR) of low-impact development measures is significantly influenced by its operating characteristics, particularly for residential stormwater detention tanks (SWDTs). The multi-objective operation strategy of SWDTs, encompassing toilet flushing (TF), green space irrigation (GSI), combined TF and GSI (TF-GSI), and peak flow reduction (PFR) rate, were compared using a case study in Beijing based on the stormwater management model. The findings indicate that the VCRAR for TF, GSI, and TF-GSI rainwater harvesting targets was 89.05, 77.16, and 91.21%, respectively. The operating scheme and return periods have a significant impact on the PFR rate's effectiveness. When the return period was lower than 10 years, the SWDT does not reach its maximum storage capacity, and the PFR rate was increased with increasing the return period: the PFR rate was 71.47% when the design return period was 10 years. It will also produce the phenomena of water inrush, and the overflow volume will grow rapidly when the SWDT reaches its maximum storage capacity. Hence, the operation of SWDTs may be integrated with real-time control to optimize the VCRAR for rainwater reuse and flood migration, thereby enhancing the volume utilization efficiency of SWDTs.<\/jats:p>","DOI":"10.2166\/wst.2023.422","type":"journal-article","created":{"date-parts":[[2023,12,26]],"date-time":"2023-12-26T18:26:04Z","timestamp":1703615164000},"page":"54-70","update-policy":"https:\/\/doi.org\/10.2166\/iwapcrossmarkpolicypage","source":"Crossref","is-referenced-by-count":10,"title":["Assessing the effectiveness of a residential-scale detention tank operated in a multi-objective approach using SWMM"],"prefix":"10.2166","volume":"89","author":[{"given":"Shiping","family":"Wang","sequence":"first","affiliation":[{"name":"a Key Laboratory of Urban Stormwater System and Water Environment (Ministry of Education), Beijing University of Civil Engineering and Architecture, Beijing 100044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianlong","family":"Wang","sequence":"additional","affiliation":[{"name":"b Beijing Energy Conservation & Sustainable Urban and Rural Development Provincial and Ministry Co-construction Collaboration Innovation Center, Beijing University of Civil Engineering and Architecture, Beijing 100044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chonghua","family":"Xue","sequence":"additional","affiliation":[{"name":"b Beijing Energy Conservation & Sustainable Urban and Rural Development Provincial and Ministry Co-construction Collaboration Innovation Center, Beijing University of Civil Engineering and Architecture, Beijing 100044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rongting","family":"Qiu","sequence":"additional","affiliation":[{"name":"a Key Laboratory of Urban Stormwater System and Water Environment (Ministry of Education), Beijing University of Civil Engineering and Architecture, Beijing 100044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shi","family":"Sun","sequence":"additional","affiliation":[{"name":"c Science and Technology Management Department, Beijing Architectural Decoration Design & Engineering Co., Ltd, Beijing 100123, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zitong","family":"Yang","sequence":"additional","affiliation":[{"name":"d Beijing Sustainable Urban Drainage System Construction and Risk Control Engineering Technology Research Center, Beijing University of Civil Engineering and Architecture, Beijing 100044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanhui","family":"Qiao","sequence":"additional","affiliation":[{"name":"c Science and Technology Management Department, Beijing Architectural Decoration Design & Engineering Co., Ltd, Beijing 100123, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"945","published-online":{"date-parts":[[2023,12,26]]},"reference":[{"key":"key-10.2166\/wst.2023.422-1","volume-title":"Code for Design of Stormwater Management and Harvest Engineering in Sponge City Construction","author":"Beijing Institute of Architectural Design, Beijing General Municipal Engineering Design & Research Institute Co., Ltd., Beijing Water Science & Technology Institute, Tianjin Municipal Engineering Design & Research Institute, Hebei Institute of Architectural Design & Research Co., Ltd","year":"2021"},{"key":"key-10.2166\/wst.2023.422-2","volume-title":"Standards for Efficient Irrigation Technology of Turf","author":"Beijing Water Conservation Management Center, China Agricultural University, Beijing Institute of Landscape Architecture","year":"2006"},{"key":"key-10.2166\/wst.2023.422-3","doi-asserted-by":"publisher","DOI":"10.3390\/w14213468"},{"key":"key-10.2166\/wst.2023.422-4","doi-asserted-by":"publisher","DOI":"10.13928\/j.cnki.wrahe.2022.06.008"},{"key":"key-10.2166\/wst.2023.422-5","doi-asserted-by":"publisher","DOI":"10.1016\/j.uclim.2021.101058"},{"key":"key-10.2166\/wst.2023.422-6","doi-asserted-by":"publisher","DOI":"10.2166\/aqua.2020.047"},{"key":"key-10.2166\/wst.2023.422-7","doi-asserted-by":"publisher","DOI":"10.3390\/w11071389"},{"key":"key-10.2166\/wst.2023.422-8","doi-asserted-by":"publisher","DOI":"10.1007\/s11356-020-08630-6"},{"key":"key-10.2166\/wst.2023.422-9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclepro.2022.130991"},{"key":"key-10.2166\/wst.2023.422-10","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2021.152701"},{"key":"key-10.2166\/wst.2023.422-11","doi-asserted-by":"publisher","DOI":"10.30955\/gnj.002535"},{"key":"key-10.2166\/wst.2023.422-12","doi-asserted-by":"publisher","DOI":"10.1007\/s11269-019-02300-0"},{"key":"key-10.2166\/wst.2023.422-13","doi-asserted-by":"publisher","DOI":"10.3390\/w11122428"},{"key":"key-10.2166\/wst.2023.422-14","doi-asserted-by":"publisher","DOI":"10.1016\/j.envsoft.2018.09.020"},{"key":"key-10.2166\/wst.2023.422-15","volume-title":"Standard for Water Saving Design in Civil Building","author":"Ministry of Housing and Urban-Rural Development","year":"2010"},{"key":"key-10.2166\/wst.2023.422-16","volume-title":"Technical Code for Rainwater Management and Utilization of Building and Sub-District","author":"Ministry of Housing and Urban-Rural Development","year":"2016"},{"key":"key-10.2166\/wst.2023.422-17","volume-title":"Standard for Design of Building Reclaimed Water System","author":"Ministry of Housing and Urban-Rural Development","year":"2018"},{"key":"key-10.2166\/wst.2023.422-18","doi-asserted-by":"publisher","DOI":"10.1016\/j.rineng.2021.100307"},{"key":"key-10.2166\/wst.2023.422-19","doi-asserted-by":"publisher","DOI":"10.3390\/w14040571"},{"key":"key-10.2166\/wst.2023.422-20","doi-asserted-by":"publisher","DOI":"10.2166\/wcc.2022.164"},{"key":"key-10.2166\/wst.2023.422-21","doi-asserted-by":"publisher","DOI":"10.1007\/s11356-020-07842-0"},{"key":"key-10.2166\/wst.2023.422-22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclepro.2018.02.130"},{"key":"key-10.2166\/wst.2023.422-23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhydrol.2019.124127"}],"container-title":["Water Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/iwaponline.com\/wst\/article-pdf\/89\/1\/54\/1352928\/wst089010054.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iwaponline.com\/wst\/article-pdf\/89\/1\/54\/1352928\/wst089010054.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,31]],"date-time":"2024-01-31T19:18:02Z","timestamp":1706728682000},"score":1,"resource":{"primary":{"URL":"https:\/\/iwaponline.com\/wst\/article\/89\/1\/54\/99543\/Assessing-the-effectiveness-of-a-residential-scale"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,26]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12,26]]},"published-print":{"date-parts":[[2024,1,1]]}},"URL":"https:\/\/doi.org\/10.2166\/wst.2023.422","relation":{},"ISSN":["0273-1223","1996-9732"],"issn-type":[{"value":"0273-1223","type":"print"},{"value":"1996-9732","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,26]]}}}