{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T23:40:49Z","timestamp":1782603649912,"version":"3.54.5"},"reference-count":21,"publisher":"Japanese Society of Internal Medicine","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Intern. Med."],"published-print":{"date-parts":[[2020,6,15]]},"DOI":"10.2169\/internalmedicine.4271-19","type":"journal-article","created":{"date-parts":[[2020,3,4]],"date-time":"2020-03-04T22:09:39Z","timestamp":1583359779000},"page":"1525-1530","source":"Crossref","is-referenced-by-count":10,"title":["Use of a Non-invasive Cardiac Output Measurement in a Patient with Low-output Dilated Cardiomyopathy"],"prefix":"10.2169","volume":"59","author":[{"given":"Atsuko","family":"Nakayama","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Medicine, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kentaro","family":"Iwama","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naohiro","family":"Makise","sequence":"additional","affiliation":[{"name":"Department of Pathology, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukako","family":"Domoto","sequence":"additional","affiliation":[{"name":"Department of Pathology, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junichi","family":"Ishida","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Morita","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Issei","family":"Komuro","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, The University of Tokyo Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"962","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Forrester JS, Diamond GA, Swan HJ. Correlative classification of clinical and hemodynamic function after acute myocardial infarction. Am J Cardiol 39: 137-145, 1977.","DOI":"10.1016\/S0002-9149(77)80182-3"},{"key":"2","unstructured":"2. Rudzi\u0144ski PN, Henzel J, Dzieli\u0144ska Z, et al. Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre&apos;s experience. Postepy Kardiol Interwencyjnej 12: 135-139, 2016."},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Nguyen LS, Squara P. Non-invasive monitoring of cardiac output in critical care medicine. Front Med (Lausanne) 4: 200, 2017.","DOI":"10.3389\/fmed.2017.00200"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Norozi K, Beck C, Osthaus WA, et al. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth 100: 88-94, 2008.","DOI":"10.1093\/bja\/aem320"},{"key":"5","unstructured":"5. Rauch R, Welisch E, Lansdell N, et al. Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography. J Clin Monit Comput 27: 187-193, 2013."},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Wong J, Agus MS, Steil GM. Cardiac parameters in children recovered from acute illness as measured by electrical cardiometry and comparisons to the literature. J Clin Monit Comput 27: 81-91, 2013.","DOI":"10.1007\/s10877-012-9401-x"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Petter H, Erik A, Bj\u00f6rn E, G\u00f6ran R. Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution. Clin Physiol Funct Imaging 31: 39-47, 2011.","DOI":"10.1111\/j.1475-097X.2010.00977.x"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Trinkmann F, Berger M, Doesch C, et al. Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output. J Clin Monit Comput 30: 399-408, 2016.","DOI":"10.1007\/s10877-015-9731-6"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Forssmann W. Die Sondierung des rechten Herzens. Klin Wochenschr 8: 2085, 1929.","DOI":"10.1007\/BF01875120"},{"key":"10","unstructured":"10. Cournand A. Cardiac catheterization; development of the technique, its contributions to experimental medicine, and its initial applications in man. Acta Med Scand Suppl 579: 3-32, 1975."},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Scheinman MM, Abbott JA, Rapaport E. Clinical uses of a flow-directed right heart catheter. Arch Intern Med 124: 19-24, 1969.","DOI":"10.1001\/archinte.124.1.19"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Swan HJ, Ganz W, Forrester J, et al. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 283: 447-451, 1970.","DOI":"10.1056\/NEJM197008272830902"},{"key":"13","doi-asserted-by":"publisher","unstructured":"13. Harvey S, Harrison DA, Singer M, et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 366: 472-477, 2005.","DOI":"10.1016\/S0140-6736(05)67061-4"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Sandham JD, Hull RD, Brant RF, et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 348: 5-14, 2003.","DOI":"10.1056\/NEJMoa021108"},{"key":"15","doi-asserted-by":"publisher","unstructured":"15. Shah MR, Hasselblad V, Stevenson LW, et al. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA 294: 1664-1670, 2005.","DOI":"10.1001\/jama.294.13.1664"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Rajaram SS, Desai NK, Kalra A, et al. Pulmonary artery catheters for adult patients in intensive care. Cochrane Database Syst Rev 2: CD003408, 2013.","DOI":"10.1002\/14651858.CD003408.pub3"},{"key":"17","doi-asserted-by":"publisher","unstructured":"17. Chatterjee K. The Swan-Ganz catheters: past, present, and future. A viewpoint. Circulation 119: 147-152, 2009.","DOI":"10.1161\/CIRCULATIONAHA.108.811141"},{"key":"18","doi-asserted-by":"publisher","unstructured":"18. Yancy CW, Jessup M, Bozkurt B, et al. 2013 ACCF\/AHA guideline for the management of heart failure: a report of the American College of Cardiology Foundation\/American Heart Association Task Force on practice guidelines. Circulation 128: e240-e327, 2013.","DOI":"10.1161\/CIR.0b013e31829e8776"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Zoremba N, Bickenbach J, Krauss B, et al. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand 51: 1314-1319, 2007.","DOI":"10.1111\/j.1399-6576.2007.01445.x"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Marqu\u00e9 S, Cariou A, Chiche JD, et al. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care 13: R73, 2009.","DOI":"10.1186\/cc7884"},{"key":"21","unstructured":"21. Sanders M, Servaas S, Slagt C. Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis. J Clin Monit Comput. Forthcoming."}],"container-title":["Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/internalmedicine\/59\/12\/59_4271-19\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,20]],"date-time":"2020-06-20T03:30:15Z","timestamp":1592623815000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/internalmedicine\/59\/12\/59_4271-19\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,15]]},"references-count":21,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2169\/internalmedicine.4271-19","relation":{},"ISSN":["0918-2918","1349-7235"],"issn-type":[{"value":"0918-2918","type":"print"},{"value":"1349-7235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,15]]}}}