{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T09:27:18Z","timestamp":1794821238546,"version":"4.9.1"},"reference-count":27,"publisher":"Bentham Science Publishers Ltd.","license":[{"start":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T00:00:00Z","timestamp":1784937600000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/legalcode"}],"content-domain":{"domain":["eurekaselect.com"],"crossmark-restriction":true},"short-container-title":["CMIR"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>To estimate the contrast-to-noise ratio (CNR) of liver metastases with electron density (ED) derived from dual-energy computed tomography and\ncompare it with conventional and virtual monoenergetic images at 40 keV in both the unenhanced and portal-dominant phases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This observational retrospective, single-institution study included 32 patients with 49 liver metastases originating from digestive adenocarcinoma.\nAll patients underwent dual-energy computed tomography (Spectral IQON\u00ae, Philips Healthcare) during unenhanced and portal-dominant phases.\nConventional, virtual monoenergetic (VMI) images at 40 keV and ED images were reconstructed. The CNR of each metastasis was measured for\neach reconstruction in both the unenhanced and portal-dominant phases. Comparisons between techniques were conducted using linear mixed\nmodel regression.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Forty-nine liver metastases were included. For unenhanced acquisitions, ED demonstrated a statistically significantly higher CNR than both VMIs\nat 40 keV (mean difference 12.56 [95% IC, 10.17 to 14.95], p &lt; 0.001) and conventional reconstructions (mean difference 12.83 [95% IC, 10.44 to\n15.55], p &lt; 0.001).\nSimilarly, in the portal venous phase, ED showed a significantly higher CNR compared with both 40 keV monoenergetic (mean difference 9.81\n[95% IC, 7.42 to 12.20], p &lt; 0.001) and conventional reconstructions (mean difference 16.62 [95% IC, 14.23 to 19.00], p &lt; 0.001). Moreover, a\nsignificantly better CNR was observed between unenhanced ED and portal venous 40 keV VMI (14.4626 \u00b1 7.5 vs 11.1810 \u00b1 6.2, respectively; p =\n0.007).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Few studies have investigated electron density. These findings suggest that the CNR of liver metastases with ED is better than conventional and\nVMIs at 40 keV reconstructions, in both the unenhanced and portal-dominant phases. The single-center design and the small sample size limit the\ngeneralizability of these results.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Electron density provides a significantly better CNR for liver metastasis compared with both conventional and VMI at 40 keV reconstructions.\nFurther studies are required to demonstrate that this gain in CNR improves the detection of hepatic metastases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2174\/0115734056468428260624144643","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T04:40:07Z","timestamp":1784004007000},"update-policy":"https:\/\/doi.org\/10.2174\/bsp_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Electron Density Dual-energy CT for Liver Metastasis Detection Compared with Conventional and Virtual Monoenergetic Images at 40 keV"],"prefix":"10.2174","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-5700-6598","authenticated-orcid":true,"given":"C\u00e9cile","family":"Chabrier","sequence":"first","affiliation":[{"name":"Digestive Imaging Unit, Center Hospitalier Universitaire de Lille, Lille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxime","family":"Leroy","sequence":"additional","affiliation":[{"name":"SEED Unit (Statistics, Economic Evaluation, and Data Management), Centre Hospitalier Universitaire de Lille, Lille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pr Olivier","family":"Ernst","sequence":"additional","affiliation":[{"name":"Digestive Imaging Unit, Center Hospitalier Universitaire de Lille, Lille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"965","reference":[{"key":"ref=1","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3322\/caac.21660","volume":"71","author":"Sung H.","year":"2021","unstructured":"Sung H.; Ferlay J.; Siegel R.L.; Laversanne M.; Soerjomataram I.; Jemal A.; Bray F.; Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin  2021,71(3),209-249","journal-title":"CA Cancer J Clin"},{"key":"ref=2","doi-asserted-by":"publisher","DOI":"10.1016\/j.canep.2020.101760","volume":"67","author":"Horn S.R.","year":"2020","unstructured":"Horn S.R.; Stoltzfus K.C.; Lehrer E.J.; Dawson L.A.; Tchelebi L.; Gusani N.J.; Sharma N.K.; Chen H.; Trifiletti D.M.; Zaorsky N.G.; Epidemiology of liver metastases. Cancer Epidemiol  2020,67","journal-title":"Cancer Epidemiol"},{"key":"ref=3","doi-asserted-by":"publisher","first-page":"2806","DOI":"10.1200\/JCO.21.02505","volume":"40","author":"Raphael M.J.","year":"2022","unstructured":"Raphael M.J.; Karanicolas P.J.; Regional therapy for colorectal cancer liver metastases: Which modality and when? J Clin Oncol  2022,40(24),2806-2817","journal-title":"J Clin Oncol"},{"key":"ref=4","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1148\/radiol.2312021639","volume":"231","author":"Soyer P.","year":"2004","unstructured":"Soyer P.; Poccard M.; Boudiaf M.; Abitbol M.; Hamzi L.; Panis Y.; Valleur P.; Rymer R.; Detection of hypovascular hepatic metastases at triple-phase helical CT: Sensitivity of phases and comparison with surgical and histopathologic findings. Radiology  2004,231(2),413-420","journal-title":"Radiology"},{"key":"ref=5","doi-asserted-by":"publisher","first-page":"555","DOI":"10.3348\/kjr.2017.18.4.555","volume":"18","author":"Goo H.W.","year":"2017","unstructured":"Goo H.W.; Goo J.M.; Dual-Energy C.T.; Dual-energy CT: New horizon in medical imaging. Korean J Radiol  2017,18(4),555-569","journal-title":"Korean J Radiol"},{"key":"ref=6","doi-asserted-by":"publisher","DOI":"10.2174\/0115734056335472250310085121","volume":"21","author":"Cao M.","year":"2025","unstructured":"Cao M.; Qiao Y.; Gao X.; Liu X.; Yang A.; Fan R.; Zhou B.; Huang B.; Cao Y.; Research progress of dual-energy CT in diagnosis and evaluation of curative effect of liver cancer: A review. Curr Med Imaging Rev  2025,21","journal-title":"Curr Med Imaging Rev"},{"key":"ref=7","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/s13244-017-0571-4","volume":"8","author":"Rassouli N.","year":"2017","unstructured":"Rassouli N.; Etesami M.; Dhanantwari A.; Rajiah P.; Detector-based spectral CT with a novel dual-layer technology: Principles and applications. Insights Imaging  2017,8(6),589-598","journal-title":"Insights Imaging"},{"key":"ref=8","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1097\/RLI.0b013e318240a874","volume":"47","author":"Yamada Y.","year":"2012","unstructured":"Yamada Y.; Jinzaki M.; Tanami Y.; Abe T.; Kuribayashi S.; Virtual monochromatic spectral imaging for the evaluation of hypovascular hepatic metastases: The optimal monochromatic level with fast kilovoltage switching dual-energy computed tomography. Invest Radiol  2012,47(5),292-298","journal-title":"Invest Radiol"},{"key":"ref=9","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1016\/j.ejrad.2014.07.009","volume":"83","author":"Wang Q.","year":"2014","unstructured":"Wang Q.; Shi G.; Qi X.; Fan X.; Wang L.; Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization. Eur J Radiol  2014,83(10),1759-1764","journal-title":"Eur J Radiol"},{"key":"ref=10","doi-asserted-by":"publisher","first-page":"2837","DOI":"10.1007\/s00330-018-5789-0","volume":"29","author":"Nagayama Y.","year":"2019","unstructured":"Nagayama Y.; Iyama A.; Oda S.; Taguchi N.; Nakaura T.; Utsunomiya D.; Kikuchi Y.; Yamashita Y.; Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: Impact of closing k-edge on image quality and lesion detectability. Eur Radiol  2019,29(6),2837-2847","journal-title":"Eur Radiol"},{"key":"ref=11","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1364\/josaa.16.000633","volume":"16","author":"Burgess A.E.","year":"1999","unstructured":"Burgess A.E.; the Rose model, revisited. J Opt Soc Am A Opt Image Sci Vis  1999,16(3),633-646","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"ref=12","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1097\/RCT.0000000000000129","volume":"38","author":"Tatsugami F.","year":"2014","unstructured":"Tatsugami F.; Higaki T.; Kiguchi M.; Tsushima S.; Taniguchi A.; Kaichi Y.; Yamagami T.; Awai K.; Measurement of electron density and effective atomic number by dual-energy scan using a 320-detector computed tomography scanner with raw data-based analysis: A phantom study. J Comput Assist Tomogr  2014,38(6),824-827","journal-title":"J Comput Assist Tomogr"},{"key":"ref=13","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.ejmp.2018.11.008","volume":"56","author":"Ohira S.","year":"2018","unstructured":"Ohira S.; Washio H.; Yagi M.; Karino T.; Nakamura K.; Ueda Y.; Miyazaki M.; Koizumi M.; Teshima T.; Estimation of electron density, effective atomic number and stopping power ratio using dual-layer computed tomography for radiotherapy treatment planning. Phys Med  2018,56,34-40","journal-title":"Phys Med"},{"key":"ref=14","doi-asserted-by":"publisher","first-page":"304","DOI":"10.21037\/cdt-24-28","volume":"14","author":"Rodriguez-Granillo G.A.","year":"2024","unstructured":"Rodriguez-Granillo G.A.; Cirio J.; Morales C.; Safady J.; Fontana L.; Fernandez M.; Diluca P.; Lylyk P.; Thrombus discrimination with electron density: Potential implications for non-contrast computed tomography imaging. Cardiovasc Diagn Ther  2024,14(2),304-310","journal-title":"Cardiovasc Diagn Ther"},{"key":"ref=15","doi-asserted-by":"publisher","first-page":"1841","DOI":"10.3390\/diagnostics11101841","volume":"11","author":"Bae K.","year":"2021","unstructured":"Bae K.; Jeon K.N.; Diagnosis of pulmonary embolism in unenhanced dual energy CT using an electron density image. Diagnostics  2021,11(10),1841","journal-title":"Diagnostics"},{"key":"ref=16","doi-asserted-by":"publisher","first-page":"2209","DOI":"10.1007\/s00330-021-08374-y","volume":"32","author":"Shim E.","year":"2022","unstructured":"Shim E.; Kim B.H.; Kang W.Y.; Hong S.J.; Kang C.H.; Ahn K.S.; Lee H.; Kwack T.J.; Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images. Eur Radiol  2022,32(4),2209-2220","journal-title":"Eur Radiol"},{"key":"ref=17","doi-asserted-by":"publisher","first-page":"349","DOI":"10.2214\/AJR.20.23546","volume":"216","author":"Daoud B.","year":"2021","unstructured":"Daoud B.; Cazejust J.; Tavolaro S.; Durand S.; Pommier R.; Hamrouni A.; Bornet G.; Could Spectral CT Have a Potential Benefit in Coronavirus Disease (COVID-19)? AJR Am J Roentgenol  2021,216(2),349-354","journal-title":"AJR Am J Roentgenol"},{"key":"ref=18","doi-asserted-by":"publisher","DOI":"10.2174\/0115734056360004250828115402","volume":"21","author":"Yadav S.K.","year":"2025","unstructured":"Yadav S.K.; Deng N.; Ma J.; Liu Y.; Zhang C.; Liu L.; Diagnostic Value of Dual Energy Technology of Dual Source CT in Differentiation Grade of Colorectal Cancer. Curr Med Imaging Rev  2025,21","journal-title":"Curr Med Imaging Rev"},{"key":"ref=19","doi-asserted-by":"publisher","first-page":"4988","DOI":"10.1002\/mp.15832","volume":"49","author":"Hsieh S.S.","year":"2022","unstructured":"Hsieh S.S.; Leng S.; Yu L.; Huber N.R.; McCollough C.H.; A minimum SNR criterion for computed tomography object detection in the projection domain. Med Phys  2022,49(8),4988-4998","journal-title":"Med Phys"},{"key":"ref=20","doi-asserted-by":"publisher","first-page":"66","DOI":"10.2214\/AJR.21.26208","volume":"218","author":"Nagano H.","year":"2022","unstructured":"Nagano H.; Takumi K.; Nakajo M.; Fukukura Y.; Kumagae Y.; Jinguji M.; Tani A.; Yoshiura T.; Dual-Energy CT\u2013Derived Electron Density for Diagnosing Metastatic Mediastinal Lymph Nodes in Non\u2013Small Cell Lung Cancer: Comparison With Conventional CT and FDG PET\/CT Findings. AJR Am J Roentgenol  2022,218(1),66-74","journal-title":"AJR Am J Roentgenol"},{"key":"ref=21","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1111\/1754-9485.13528","volume":"67","author":"Cheng C.T.","year":"2023","unstructured":"Cheng C.T.; Gwini S.; Craig G.; A quantitative analysis of spectral computed tomography characteristics of osseous metastases. J Med Imaging Radiat Oncol  2023,67(6),595-601","journal-title":"J Med Imaging Radiat Oncol"},{"key":"ref=22","doi-asserted-by":"publisher","first-page":"3448","DOI":"10.21037\/qims-20-3","volume":"11","author":"Qiu L.","year":"2021","unstructured":"Qiu L.; Hu J.; Weng Z.; Liu S.; Jiang G.; Cai X.; A prospective study of dual-energy computed tomography for differentiating metastatic and non-metastatic lymph nodes of colorectal cancer. Quant Imaging Med Surg  2021,11(8),3448-3459","journal-title":"Quant Imaging Med Surg"},{"key":"ref=23","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s41747-018-0051-8","volume":"2","author":"Mei K.","year":"2018","unstructured":"Mei K.; Ehn S.; Oechsner M.; Kopp F.K.; Pfeiffer D.; Fingerle A.A.; Pfeiffer F.; Combs S.E.; Wilkens J.J.; Rummeny E.J.; No\u00ebl P.B.; Dual-layer spectral computed tomography: Measuring relative electron density. Eur Radiol Exp  2018,2(1),20","journal-title":"Eur Radiol Exp"},{"key":"ref=24","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1111\/his.12602","volume":"66","author":"Righi A.","year":"2015","unstructured":"Righi A.; Sarotto I.; Casorzo L.; Cavalchini S.; Frangipane E.; Risio M.; Tumour budding is associated with hypoxia at the advancing front of colorectal cancer. Histopathology  2015,66(7),982-990","journal-title":"Histopathology"},{"key":"ref=25","author":"Hsieh J.","year":"2003","unstructured":"Hsieh J.;  Computed Tomography: Principles, Design, Artifacts, and Recent Advances  2003","journal-title":"Computed Tomography: Principles, Design, Artifacts, and Recent Advances"},{"key":"ref=26","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1053\/j.sult.2016.08.005","volume":"37","author":"Karaosmanoglu A.D.","year":"2016","unstructured":"Karaosmanoglu A.D.; Onur M.R.; Ozmen M.N.; Akata D.; Karcaaltincaba M.; Magnetic Resonance Imaging of Liver Metastasis. Semin Ultrasound CT MR  2016,37(6),533-548","journal-title":"Semin Ultrasound CT MR"},{"key":"ref=27","doi-asserted-by":"publisher","DOI":"10.1118\/1.4881148","volume":"41","author":"Vaishnav J.Y.","year":"2014","unstructured":"Vaishnav J.Y.; Jung W.C.; Popescu L.M.; Zeng R.; Myers K.J.; Objective assessment of image quality and dose reduction in CT iterative reconstruction. Med Phys  2014,41(7)","journal-title":"Med Phys"}],"container-title":["Current Medical Imaging Formerly Current Medical Imaging Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.eurekaselect.com\/article\/download\/255911","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/255911\/article","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/article\/download\/255911","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T09:08:29Z","timestamp":1794820109000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.eurekaselect.com\/255911\/article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":27,"alternative-id":["LiveAll1"],"URL":"https:\/\/doi.org\/10.2174\/0115734056468428260624144643","relation":{},"ISSN":["1573-4056"],"issn-type":[{"value":"1573-4056","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Double blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2026-01-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-29","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-25","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e15734056468428"}}