{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T04:41:40Z","timestamp":1695530500127},"reference-count":100,"publisher":"Bentham Science Publishers Ltd.","issue":"1","content-domain":{"domain":["eurekaselect.com"],"crossmark-restriction":true},"short-container-title":["CTMC"],"published-print":{"date-parts":[[2020,1,22]]},"abstract":"<jats:sec><jats:title \/><jats:p>The advancement of cardiac surgery benefits from the continual technological progress of cardiopulmonary bypass (CPB). Every improvement in the CPB technology requires further clinical and laboratory tests to prove its safety and effectiveness before it can be widely used in clinical practice. In order to reduce the priming volume and eliminate a separate arterial filter in the CPB circuit, several manufacturers developed novel hollow-fiber membrane oxygenators with integrated arterial filters (IAF). Clinical and experimental studies demonstrated that an oxygenator with IAF could reduce total priming volume, blood donor exposure and gaseous microemboli delivery to the patient. It can be easily set up and managed, simplifying the CPB circuit without sacrificing safety. An oxygenator with IAF is expected to be more beneficial to the patients with low body weight and when using a minimized extracorporeal circulation system. The aim of this review manuscript was to discuss briefly the concept of integration, the current oxygenators with IAF, and the in-vitro \/ in-vivo performance of the oxygenators with IAF.<\/jats:p><\/jats:sec>","DOI":"10.2174\/1568026619666191210161013","type":"journal-article","created":{"date-parts":[[2019,12,10]],"date-time":"2019-12-10T13:10:46Z","timestamp":1575983446000},"page":"78-85","update-policy":"http:\/\/dx.doi.org\/10.2174\/bsp_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Pumping O2 with no N2: An Overview of Hollow Fiber Membrane Oxygenators with Integrated Arterial Filters"],"prefix":"10.2174","volume":"20","author":[{"given":"Anxin","family":"Liu","sequence":"first","affiliation":[{"name":"Center for Cardiac Intensive Care, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing Anzhen Hospital, Capital Medical University, Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiquan","family":"Sun","sequence":"additional","affiliation":[{"name":"Center for Cardiac Intensive Care, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing Anzhen Hospital, Capital Medical University, Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qier","family":"Liu","sequence":"additional","affiliation":[{"name":"Biologic Sciences, College of Liberal Arts and Sciences, University of Connecticut, Storrs, CT, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Zhu","sequence":"additional","affiliation":[{"name":"Hunan University of Medicine, Huaihua, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shigang","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Surgery, University of Maryland School of Medicine, Baltimore, MD, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"965","reference":[{"key":"ref=1","first-page":"73","volume":"19","author":"Kurusz M.","year":"1985","unstructured":"Kurusz M.; Gaseous microemboli: sources, causes, and clinical considerations. Med Instrum 1985,19(2),73-76","journal-title":"Med Instrum"},{"key":"ref=2","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.ejcts.2005.11.006","volume":"29","author":"Rodriguez R.A.","year":"2006","unstructured":"Rodriguez R.A.; Rubens F.; Belway D.; Nathan H.J.; Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypass. Eur J Cardiothorac Surg 2006,29(2),175-180","journal-title":"Eur J Cardiothorac Surg"},{"key":"ref=3","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1111\/j.1525-1594.2009.00910.x","volume":"33","author":"Wang S.","year":"2009","unstructured":"Wang S.; Woitas K.; Clark J.B.; Myers J.L.; Undar A.; Clinical real-time monitoring of gaseous microemboli in pediatric cardiopulmonary bypass. Artif Organs 2009,33(11),1026-1030","journal-title":"Artif Organs"},{"key":"ref=4","doi-asserted-by":"publisher","first-page":"2918","DOI":"10.1378\/chest.128.4.2918","volume":"128","author":"Barak M.","year":"2005","unstructured":"Barak M.; Katz Y.; Microbubbles: pathophysiology and clinical implications. Chest 2005,128(4),2918-2932","journal-title":"Chest"},{"key":"ref=5","first-page":"31","volume":"41","author":"Willcox T.W.","year":"2009","unstructured":"Willcox T.W.; Mitchell S.J.; Microemboli in our bypass circuits: a contemporary audit. J Extra Corpor Technol 2009,41(4),31-37","journal-title":"J Extra Corpor Technol"},{"key":"ref=6","doi-asserted-by":"publisher","first-page":"2132","DOI":"10.1016\/S0003-4975(02)04081-X","volume":"74","author":"Jones T.J.","year":"2002","unstructured":"Jones T.J.; Deal D.D.; Vernon J.C.; Blackburn N.; Stump D.A.; Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass? Ann Thorac Surg 2002,74(6),2132-2137","journal-title":"Ann Thorac Surg"},{"key":"ref=7","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1097\/MAT.0b013e318185da5b","volume":"54","author":"Wang S.","year":"2008","unstructured":"Wang S.; Kunselman A.R.; Myers J.L.; Undar A.; Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model. ASAIO J 2008,54(5),538-541","journal-title":"ASAIO J"},{"key":"ref=8","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1097\/MAT.0b013e3181588dc3","volume":"53","author":"\u00dcndar A.","year":"2007","unstructured":"\u00dcndar A.; Ji B.; Kunselman A.R.; Myers J.L.; Detection and classification of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model. ASAIO J 2007,53(6),725-729","journal-title":"ASAIO J"},{"key":"ref=9","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1097\/MAT.0b013e31816ecfff","volume":"54","author":"Schreiner R.S.","year":"2008","unstructured":"Schreiner R.S.; Rider A.R.; Myers J.W.; Ji B.; Kunselman A.R.; Myers J.L.; Undar A.; Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures. ASAIO J 2008,54(3),316-324","journal-title":"ASAIO J"},{"key":"ref=10","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1067\/mtc.2001.112526","volume":"121","author":"Borger M.A.","year":"2001","unstructured":"Borger M.A.; Peniston C.M.; Weisel R.D.; Vasiliou M.; Green R.E.; Feindel C.M.; Neuropsychologic impairment after coronary bypass surgery: effect of gaseous microemboli during perfusionist interventions. J Thorac Cardiovasc Surg 2001,121(4),743-749","journal-title":"J Thorac Cardiovasc Surg"},{"key":"ref=11","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/S0003-4975(99)00475-0","volume":"68","author":"Taylor R.L.","year":"1999","unstructured":"Taylor R.L.; Borger M.A.; Weisel R.D.; Fedorko L.; Feindel C.M.; Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventions. Ann Thorac Surg 1999,68(1),89-93","journal-title":"Ann Thorac Surg"},{"key":"ref=12","doi-asserted-by":"publisher","first-page":"S2381","DOI":"10.1016\/j.athoracsur.2006.02.074","volume":"81","author":"Hsia T.Y.","year":"2006","unstructured":"Hsia T.Y.; Gruber P.J.; Factors influencing neurologic outcome after neonatal cardiopulmonary bypass: what we can and cannot control. Ann Thorac Surg 2006,81(6),S2381-S2388","journal-title":"Ann Thorac Surg"},{"key":"ref=13","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/S0022-5223(95)70386-1","volume":"109","author":"Clark R.E.","year":"1995","unstructured":"Clark R.E.; Brillman J.; Davis D.A.; Lovell M.R.; Price T.R.; Magovern G.J.; Microemboli during coronary artery bypass grafting. Genesis and effect on outcome. J Thorac Cardiovasc Surg 1995,109(2),249-257","journal-title":"J Thorac Cardiovasc Surg"},{"key":"ref=14","first-page":"271","volume":"39","author":"De Somer F.","year":"2007","unstructured":"De Somer F.; Dierickx P.; Dujardin D.; Impact of oxygenator characteristics on its capability to remove gaseous microemboli. J Extra Corpor Technol 2007,39(4),271-273","journal-title":"J Extra Corpor Technol"},{"key":"ref=15","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1056\/NEJM200002173420706","volume":"342","author":"Muth C.M.","year":"2000","unstructured":"Muth C.M.; Shank E.S.; Gas embolism. N Engl J Med 2000,342(7),476-482","journal-title":"N Engl J Med"},{"key":"ref=16","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1093\/icvts\/ivu088","volume":"19","author":"Fouilloux V.","year":"2014","unstructured":"Fouilloux V.; Davey L.; Van Arsdell G.S.; Honjo O.; Foam formation and acute air emboli with the maquet paediatric Quadrox I: a word of caution. Interact Cardiovasc Thorac Surg 2014,19(1),163-165","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"ref=17","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1097\/MAT.0b013e318158e3f9","volume":"53","author":"Rider A.R.","year":"2007","unstructured":"Rider A.R.; Schreiner R.S.; Undar A.; Pulsatile perfusion during cardiopulmonary bypass procedures in neonates, infants, and small children. ASAIO J 2007,53(6),706-709","journal-title":"ASAIO J"},{"key":"ref=18","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1177\/108925320500900208","volume":"9","author":"Stump D.A.","year":"2005","unstructured":"Stump D.A.; Embolic factors associated with cardiac surgery. Semin Cardiothorac Vasc Anesth 2005,9(2),151-152","journal-title":"Semin Cardiothorac Vasc Anesth"},{"key":"ref=19","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.athoracsur.2006.09.024","volume":"83","author":"Motallebzadeh R.","year":"2007","unstructured":"Motallebzadeh R.; Bland J.M.; Markus H.S.; Kaski J.C.; Jahangiri M.; Neurocognitive function and cerebral emboli: randomized study of on-pump versus off-pump coronary artery bypass surgery. Ann Thorac Surg 2007,83(2),475-482","journal-title":"Ann Thorac Surg"},{"key":"ref=20","first-page":"p. 93","author":"Hessel E.A.","year":"2008","unstructured":"Hessel E.A.; Circuitry and cannulation techniques. Cardiopulmonary Bypass Principles and Practice, 3rd ed; Gravlee, P.G.; Davis, R.F.; Stammers, A.H.; Ungerleider, R.M., Eds.; Wolters Kluwer - Lippincott Williams","journal-title":"Cardiopulmonary Bypass Principles and Practice,"},{"key":"ref=21","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1177\/026765918800300206","volume":"3","author":"Marshall L.","year":"1983","unstructured":"Marshall L.; Filtration in cardiopulmonary bypass: past, present and future. Perfusion 1983,3,135-147","journal-title":"Perfusion"},{"key":"ref=22","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1097\/MAT.0b013e318184a9ab","volume":"54","author":"Wang S.","year":"2008","unstructured":"Wang S.; Win K.N.; Kunselman A.R.; Woitas K.; Myers J.L.; Undar A.; The capability of trapping gaseous microemboli of two pediatric arterial filters with pulsatile and nonpulsatile flow in a simulated infant CPB model. ASAIO J 2008,54(5),519-522","journal-title":"ASAIO J"},{"key":"ref=23","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1097\/MAT.0b013e3181772c7b","volume":"54","author":"Wang S.","year":"2008","unstructured":"Wang S.; Baer L.; Kunselman A.R.; Myers J.L.; Undar A.; Delivery of gaseous microemboli with vacuum-assisted venous drainage during pulsatile and nonpulsatile perfusion in a simulated neonatal cardiopulmonary bypass model. ASAIO J 2008,54(4),416-422","journal-title":"ASAIO J"},{"key":"ref=24","first-page":"27","volume":"44","author":"De Somer F.","year":"2012","unstructured":"De Somer F.; Evidence-based used, yet still controversial: the arterial filter. J Extra Corpor Technol 2012,44(1),27-30","journal-title":"J Extra Corpor Technol"},{"key":"ref=25","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.ncl.2005.10.001","volume":"24","author":"Selnes O.A.","year":"2006","unstructured":"Selnes O.A.; McKhann G.M.; Borowicz L.M.; Grega M.A.; Cognitive and neurobehavioral dysfunction after cardiac bypass procedures. Neurol Clin 2006,24(1),133-145","journal-title":"Neurol Clin"},{"key":"ref=26","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/S1053-0770(21)00593-0","volume":"13","author":"Murkin J.M.","year":"1999","unstructured":"Murkin J.M.; Etiology and incidence of brain dysfunction after cardiac surgery. J Cardiothorac Vasc Anesth 1999,13(4)(Suppl. 1),12-17","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"ref=27","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1056\/NEJM200102083440601","volume":"344","author":"Newman M.F.","year":"2001","unstructured":"Newman M.F.; Kirchner J.L.; Phillips-Bute B.; Gaver V.; Grocott H.; Jones R.H.; Mark D.B.; Reves J.G.; Blumenthal J.A.; Neurological Outcome Research Group and the Cardiothoracic Anesthesiology Research Endeavors Investigators.Longitudinal assessment of neurocognitive function after coronary-artery bypass surgery. N Engl J Med 2001,344(6),395-402","journal-title":"N Engl J Med"},{"key":"ref=28","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1177\/0267659115616179","volume":"31","author":"Johagen D.","year":"2016","unstructured":"Johagen D.; Svenmarker S.; The scientific evidence of arterial line filtration in cardiopulmonary bypass. Perfusion 2016,31(6),446-457","journal-title":"Perfusion"},{"key":"ref=29","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1111\/aor.12912","volume":"41","author":"Wang S.","year":"2017","unstructured":"Wang S.; Caneo L.F.; Jatene M.B.; Jatene F.B.; Cestari I.A.; Kunselman A.R.; \u00dcndar A.; In vitro evaluation of pediatric hollow-fiber membrane oxygenators on hemodynamic performance and gaseous microemboli handling: an international multicenter\/multidisciplinary approach. Artif Organs 2017,41(9),865-874","journal-title":"Artif Organs"},{"key":"ref=30","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1051\/ject\/201446060","volume":"46","author":"Johagen D.","year":"2014","unstructured":"Johagen D.; Appelblad M.; Svenmarker S.; Can the oxygenator screen filter reduce gaseous microemboli? J Extra Corpor Technol 2014,46(1),60-66","journal-title":"J Extra Corpor Technol"},{"key":"ref=31","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1097\/MAT.0b013e318232c1db","volume":"57","author":"Horton S.B.","year":"2011","unstructured":"Horton S.B.; Donath S.; Thuys C.A.; Bennett M.J.; Augustin S.L.; Horton A.M.; Schultz B.J.; Bottrell S.J.; Konstantinov I.; d\u2019Udekem Y.; Brizard C.; Integrated oxygenator FX05. ASAIO J 2011,57(6),522-526","journal-title":"ASAIO J"},{"key":"ref=32","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1051\/ject\/201143207","volume":"43","author":"Nuszkowski M.M.","year":"2011","unstructured":"Nuszkowski M.M.; Deutsch N.; Jonas R.A.; Zurakowski D.; Montague E.; Holt D.W.; Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass. J Extra Corpor Technol 2011,43(4),207-214","journal-title":"J Extra Corpor Technol"},{"key":"ref=33","doi-asserted-by":"publisher","first-page":"374","DOI":"10.5301\/IJAO.2011.7749","volume":"34","author":"Stehouwer M.C.","year":"2011","unstructured":"Stehouwer M.C.; Boers C.; de Vroege R.; C; Kelder J.; Yilmaz A.; Bruins P.; Clinical evaluation of the air removal characteristics of an oxygenator with integrated arterial filter in a minimized extracorporeal circuit. Int J Artif Organs 2011,34(4),374-382","journal-title":"Int J Artif Organs"},{"key":"ref=34","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1177\/0267659109106825","volume":"24","author":"Gomez D.","year":"2009","unstructured":"Gomez D.; Preston T.J.; Olshove V.F.; Phillips A.B.; Galantowicz M.E.; Evaluation of air handling in a new generation neonatal oxygenator with integral arterial filter. Perfusion 2009,24(2),107-112","journal-title":"Perfusion"},{"key":"ref=35","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/529087","author":"G\u00fcrsu \u00d6.","year":"2013,","unstructured":"G\u00fcrsu \u00d6.; Isbir S.; Ak K.; Gerin F.; Arsan S.; Comparison of new technology integrated and nonintegrated arterial filters used in cardiopulmonary bypass surgery: a randomized, prospective, and single blind study. BioMed Res Int 2013,","journal-title":"BioMed Res Int"},{"key":"ref=36","doi-asserted-by":"publisher","first-page":"5","DOI":"10.3109\/14017439409098703","volume":"28","author":"Pekna M.","year":"1994","unstructured":"Pekna M.; Borowiec J.; Fagerhol M.K.; Venge P.; Thelin S.; Biocompatibility of heparin-coated circuits used in cardiopulmonary bypass. Scand J Thorac Cardiovasc Surg 1994,28(1),5-11","journal-title":"Scand J Thorac Cardiovasc Surg"},{"key":"ref=37","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1510\/icvts.2008.183608","volume":"8","author":"Senay S.","year":"2009","unstructured":"Senay S.; Toraman F.; Gunaydin S.; Kilercik M.; Karabulut H.; Alhan C.; The impact of allogenic red cell transfusion and coated bypass circuit on the inflammatory response during cardiopulmonary bypass: a randomized study. Interact Cardiovasc Thorac Surg 2009,8(1),93-99","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"ref=38","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/S0003-4975(99)01113-3","volume":"69","author":"Shimamoto A.","year":"2000","unstructured":"Shimamoto A.; Kanemitsu S.; Fujinaga K.; Takao M.; Onoda K.; Shimono T.; Tanaka K.; Shimpo H.; Yada I.; Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass. Ann Thorac Surg 2000,69(1),115-120","journal-title":"Ann Thorac Surg"},{"key":"ref=39","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1191\/0267659104pf737oa","volume":"19","author":"Hoel T.N.","year":"2004","unstructured":"Hoel T.N.; Videm V.; Baksaas S.T.; Mollnes T.E.; Brosstad F.; Svennevig J.L.; Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery. Perfusion 2004,19(3),177-184","journal-title":"Perfusion"},{"key":"ref=40","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1111\/aor.12909","volume":"41","author":"Stehouwer M.C.","year":"2017","unstructured":"Stehouwer M.C.; de Vroege R.; Hoohenkerk G.J.F.; Hofman F.N.; Kelder J.C.; Buchner B.; de Mol B.A.; Bruins P.; Carbon dioxide flush of an integrated minimized perfusion circuit prior to priming prevents spontaneous air release into the arterial line during clinical use. Artif Organs 2017,41(11),997-1003","journal-title":"Artif Organs"},{"key":"ref=41","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1111\/j.1525-1594.2010.01082.x","volume":"34","author":"Arens J.","year":"2010","unstructured":"Arens J.; Schnoering H.; Pfennig M.; Mager I.; V\u00e1zquez-Jim\u00e9nez J.F.; Schmitz-Rode T.; Steinseifer U.; The Aachen MiniHLM--a miniaturized heart-lung machine for neonates with an integrated rotary blood pump. Artif Organs 2010,34(9),707-713","journal-title":"Artif Organs"},{"key":"ref=42","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/S1010-7940(02)00086-6","volume":"21","author":"Mueller X.M.","year":"2002","unstructured":"Mueller X.M.; Jegger D.; Augstburger M.; Horisberger J.; Godar G.; von Segesser L.K.; A new concept of integrated cardiopulmonary bypass circuit. Eur J Cardiothorac Surg 2002,21(5),840-846","journal-title":"Eur J Cardiothorac Surg"},{"key":"ref=43","year":"2019)","unstructured":"Getinge Group. Quadrox-i Adult"},{"key":"ref=44","year":"2019)","unstructured":"Terumo Cardiovascular Group. CAPIOX\u00ae FX Advance Oxygenators with Integrated Arterial Filter. [ONLINE] Available at: (Accessed 2019)"},{"key":"ref=45","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1177\/0267659112446526","volume":"27","author":"Kelting T.","year":"2012","unstructured":"Kelting T.; Searles B.; Darling E.; A survey on air bubble detector placement in the CPB circuit: a 2011 cross-sectional analysis of the practice of Certified Clinical Perfusionists. Perfusion 2012,27(4),345-351","journal-title":"Perfusion"},{"key":"ref=46","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1051\/ject\/201547174","volume":"47","author":"Newland R.F.","year":"2015","unstructured":"Newland R.F.; Baker R.A.; Mazzone A.L.; Valiyapurayil V.N.; Should air bubble detectors be used to quantify microbubble activity during cardiopulmonary bypass? J Extra Corpor Technol 2015,47(3),174-179","journal-title":"J Extra Corpor Technol"},{"key":"ref=47","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1161\/01.STR.29.3.725","volume":"29","author":"Ringelstein E.B.","year":"1998","unstructured":"Ringelstein E.B.; Droste D.W.; Babikian V.L.; Evans D.H.; Grosset D.G.; Kaps M.; Markus H.S.; Russell D.; Siebler M.; International Consensus Group on Microembolus Detection. Consensus on microembolus detection by TCD. Stroke 1998,29(3),725-729","journal-title":"Stroke"},{"key":"ref=48","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.1213\/01.ANE.0000134808.52676.4D","volume":"99","author":"Andropoulos D.B.","year":"2004","unstructured":"Andropoulos D.B.; Stayer S.A.; Diaz L.K.; Ramamoorthy C.; Neurological monitoring for congenital heart surgery. Anesth Analg 2004,99(5),1365-1375","journal-title":"Anesth Analg"},{"key":"ref=49","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/1476-7120-4-47","volume":"4","author":"Polito A.","year":"2006","unstructured":"Polito A.; Ricci Z.; Di Chiara L.; Giorni C.; Iacoella C.; Sanders S.P.; Picardo S.; Cerebral blood flow during cardiopulmonary bypass in pediatric cardiac surgery: the role of transcranial Doppler--a systematic review of the literature. Cardiovasc Ultrasound 2006,4,47","journal-title":"Cardiovasc Ultrasound"},{"key":"ref=50","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1161\/01.STR.28.3.588","volume":"28","author":"Droste D.W.","year":"1997","unstructured":"Droste D.W.; Hagedorn G.; N\u00f6tzold A.; Siemens H.J.; Sievers H.H.; Kaps M.; Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves. Stroke 1997,28(3),588-592","journal-title":"Stroke"},{"key":"ref=51","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1097\/MAT.0b013e3181857e6a","volume":"54","author":"Win K.N.","year":"2008","unstructured":"Win K.N.; Wang S.; Undar A.; Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children. ASAIO J 2008,54(5),486-490","journal-title":"ASAIO J"},{"key":"ref=52","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1016\/j.ultrasmedbio.2007.04.008","volume":"33","author":"Lynch J.E.","year":"2007","unstructured":"Lynch J.E.; Pouch A.; Sanders R.; Hinders M.; Rudd K.; Sevick J.; Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter. Ultrasound Med Biol 2007,33(10),1661-1675","journal-title":"Ultrasound Med Biol"},{"key":"ref=53","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1510\/icvts.2009.229088","volume":"10","author":"De Somer F.M.","year":"2010","unstructured":"De Somer F.M.; Vetrano M.R.; Van Beeck J.P.; Van Nooten G.J.; Extracorporeal bubbles: a word of caution. Interact Cardiovasc Thorac Surg 2010,10(6),995-1001","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"ref=54","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1051\/ject\/201749262","volume":"49","author":"Gisnarian C.J.","year":"2017","unstructured":"Gisnarian C.J.; Hedman A.; Shann K.G.; An in-vitro study comparing the GME handling of two contemporary oxygenators. J Extra Corpor Technol 2017,49(4),262-272","journal-title":"J Extra Corpor Technol"},{"key":"ref=55","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1177\/0267659115586437","volume":"31","author":"Stanzel R.D.","year":"2016","unstructured":"Stanzel R.D.; Henderson M.; An in vitro evaluation of gaseous microemboli handling by contemporary venous reservoirs and oxygenator systems using EDAC. Perfusion 2016,31(1),38-44","journal-title":"Perfusion"},{"key":"ref=56","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1051\/ject\/200941166","volume":"41","author":"Hudacko A.","year":"2009","unstructured":"Hudacko A.; Sievert A.; Sistino J.; Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study. J Extra Corpor Technol 2009,41(3),166-171","journal-title":"J Extra Corpor Technol"},{"key":"ref=57","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1177\/0267659117722595","volume":"33","author":"Segers T.","year":"2018","unstructured":"Segers T.; Stehouwer M.C.; de Somer F.M.J.J.; de Mol B.A.; Versluis M.; Optical verification and in-vitro characterization of two commercially available acoustic bubble counters for cardiopulmonary bypass systems. Perfusion 2018,33(1),16-24","journal-title":"Perfusion"},{"key":"ref=58","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1051\/ject\/201648105","volume":"48","author":"Herbst D.P.","year":"2016","unstructured":"Herbst D.P.; Effects of purge-flow rate on microbubble capture in radial arterial-line filters. J Extra Corpor Technol 2016,48(3),105-112","journal-title":"J Extra Corpor Technol"},{"key":"ref=59","author":"G.A.M.P.T. Ultrasonic Solutions","unstructured":"G.A.M.P.T. Ultrasonic Solutions; Bubble counter Available at:(Accessed 21 October 2019).","journal-title":"Bubble counter"},{"key":"ref=60","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1177\/0267659110380773","volume":"25","author":"Salavitabar A.","year":"2010","unstructured":"Salavitabar A.; Qiu F.; Kunselman A.; \u00dcndar A.; Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter. Perfusion 2010,25(6),409-415","journal-title":"Perfusion"},{"key":"ref=61","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1111\/j.1525-1594.2010.01062.x","volume":"34","author":"Qiu F.","year":"2010","unstructured":"Qiu F.; Peng S.; Kunselman A.; \u00dcndar A.; Evaluation of Capiox FX05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line. Artif Organs 2010,34(11),1053-1057","journal-title":"Artif Organs"},{"key":"ref=62","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1177\/0267659112438932","volume":"27","author":"Lin J.","year":"2012","unstructured":"Lin J.; Dogal N.M.; Mathis R.K.; Qiu F.; Kunselman A.; \u00dcndar A.; Evaluation of Quadrox-i and Capiox FX neonatal oxygenators with integrated arterial filters in eliminating gaseous microemboli and retaining hemodynamic properties during simulated cardiopulmonary bypass. Perfusion 2012,27(3),235-243","journal-title":"Perfusion"},{"key":"ref=63","doi-asserted-by":"publisher","DOI":"10.1111\/aor.13404","author":"Sathianathan S.","year":"2018","unstructured":"Sathianathan S.; Nasir R.; Wang S.; Kunselman A.R.; \u00dcndar A.; In vitro evaluation of Capiox FX05 and RX05 oxygenators in neonatal cardiopulmonary bypass circuits with varying venous reservoir and vacuum-assisted venous drainage levels. Artif Organs Epub ahead of print2018","journal-title":"Artif Organs"},{"key":"ref=64","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1177\/0267659112453078","volume":"27","author":"Mathis R.K.","year":"2012","unstructured":"Mathis R.K.; Lin J.; Dogal N.M.; Qiu F.; Kunselman A.; Wang S.; \u00dcndar A.; Evaluation of four pediatric cardiopulmonary bypass circuits in terms of perfusion quality and capturing gaseous microemboli. Perfusion 2012,27(6),470-479","journal-title":"Perfusion"},{"key":"ref=65","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1111\/aor.13090","volume":"42","author":"Moroi M.","year":"2018","unstructured":"Moroi M.; Force M.; Wang S.; Kunselman A.R.; \u00dcndar A.; In vitro comparison of pediatric oxygenators with and without integrated arterial filters in maintaining optimal hemodynamic stability and managing gaseous microemboli. Artif Organs 2018,42(4),420-431","journal-title":"Artif Organs"},{"key":"ref=66","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1051\/ject\/201042134","volume":"42","author":"Guan Y.","year":"2010","unstructured":"Guan Y.; Su X.; McCoach R.; Wise R.; Kunselman A.; Undar A.; Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter. J Extra Corpor Technol 2010,42(2),134-138","journal-title":"J Extra Corpor Technol"},{"key":"ref=67","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1051\/ject\/201143107","volume":"43","author":"Liu S.","year":"2011","unstructured":"Liu S.; Newland R.F.; Tully P.J.; Tuble S.C.; Baker R.A.; In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters. J Extra Corpor Technol 2011,43(3),107-114","journal-title":"J Extra Corpor Technol"},{"key":"ref=68","first-page":"20","volume":"1","author":"Bakker E.W.M.","year":"2011","unstructured":"Bakker E.W.M.; Visser K.; An in vitro comparison of bubble elimination in Quadrox and Capiox oxygenators. NeSECC Uptodate 2011,1,20-27","journal-title":"NeSECC Uptodate"},{"key":"ref=69","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1051\/ject\/201446229","volume":"46","author":"Potger K.C.","year":"2014","unstructured":"Potger K.C.; McMillan D.; Ambrose M.; Air transmission comparison of the affinity fusion oxygenator with an integrated arterial filter to the affinity NT oxygenator with a separate arterial Filter. J Extra Corpor Technol 2014,46(3),229-238","journal-title":"J Extra Corpor Technol"},{"key":"ref=70","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1051\/ject\/200941220","volume":"41","author":"Deptula J.","year":"2009","unstructured":"Deptula J.; Valleley M.; Glogowski K.; Detwiler J.; Hammel J.; Duncan K.; Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter. J Extra Corpor Technol 2009,41(4),220-225","journal-title":"J Extra Corpor Technol"},{"key":"ref=71","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1051\/ject\/200941226","volume":"41","author":"Preston T.J.","year":"2009","unstructured":"Preston T.J.; Gomez D.; Olshove V.F.; Phillips A.; Galantowicz M.; Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population. J Extra Corpor Technol 2009,41(4),226-230","journal-title":"J Extra Corpor Technol"},{"key":"ref=72","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1111\/j.1525-1594.2012.01469.x","volume":"36","author":"Onorati F.","year":"2012","unstructured":"Onorati F.; Santini F.; Raffin F.; Menon T.; Graziani M.S.; Chiominto B.; Milano A.; Faggian G.; Mazzucco A.; Clinical evaluation of new generation oxygenators with integrated arterial line filters for cardiopulmonary bypass. Artif Organs 2012,36(10),875-885","journal-title":"Artif Organs"},{"key":"ref=73","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1111\/aor.12000","volume":"37","author":"Dodonov M.","year":"2013","unstructured":"Dodonov M.; Milano A.; Onorati F.; Dal Corso B.; Menon T.; Ferrarini D.; Tessari M.; Faggian G.; Mazzucco A.; Gaseous micro-emboli activity during cardiopulmonary bypass in adults: pulsatile flow versus nonpulsatile flow. Artif Organs 2013,37(4),357-367","journal-title":"Artif Organs"},{"key":"ref=74","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1051\/ject\/200537201","volume":"37","author":"Myers G.J.","year":"2005","unstructured":"Myers G.J.; Gardiner K.; Ditmore S.N.; Swyer W.J.; Squires C.; Johnstone D.R.; Power C.V.; Mitchell L.B.; Ditmore J.E.; Cook B.; Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter. J Extra Corpor Technol 2005,37(2),201-206","journal-title":"J Extra Corpor Technol"},{"key":"ref=75","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1093\/icvts\/ivt264","volume":"17","author":"Milano A.D.","year":"2013","unstructured":"Milano A.D.; Dodonov M.; Onorati F.; Menon T.; Gottin L.; Malerba G.; Mazzucco A.; Faggian G.; Pulsatile flow decreases gaseous micro-bubble filtering properties of oxygenators without integrated arterial filters during cardiopulmonary bypass. Interact Cardiovasc Thorac Surg 2013,17(5),811-817","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"ref=76","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1177\/0267659113475694","volume":"28","author":"Ginther R.M.","year":"2013","unstructured":"Ginther R.M.; Gorney R.; Cruz R.; A clinical evaluation of the Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter. Perfusion 2013,28(3),194-199","journal-title":"Perfusion"},{"key":"ref=77","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1177\/0267659112450059","volume":"27","author":"Melchior R.W.","year":"2012","unstructured":"Melchior R.W.; Schiavo K.; Frey T.; Rogers D.; Patel J.; Chelnik K.; Rosenthal T.; Evaluation of the Maquet Neonatal and Pediatric Quadrox I with an integrated arterial line filter during cardiopulmonary bypass. Perfusion 2012,27(5),399-406","journal-title":"Perfusion"},{"key":"ref=78","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1177\/0267659116664402","volume":"32","author":"Stehouwer M.C.","year":"2017","unstructured":"Stehouwer M.C.; Legg K.R.; de Vroege R.; Kelder J.C.; Hofman E.; de Mol B.A.; Bruins P.; Clinical evaluation of the air-handling properties of contemporary oxygenators with integrated arterial filter. Perfusion 2017,32(2),118-125","journal-title":"Perfusion"},{"key":"ref=79","doi-asserted-by":"publisher","first-page":"230","DOI":"10.5761\/atcs.oa.18-00019","volume":"24","author":"Bleilevens C.","year":"2018","unstructured":"Bleilevens C.; Borchard R.; Stoppe C.; Goetzenich A.; Autschbac R.; Breuer T.; Retrospective analysis of air handling by contemporary oxygenators in the setting of cardiac surgery. Ann Thorac Cardiovasc Surg 2018,24(5),230-237","journal-title":"Ann Thorac Cardiovasc Surg"},{"key":"ref=80","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1051\/ject\/201749081","volume":"49","author":"Stammers A.H.","year":"2017","unstructured":"Stammers A.H.; Miller R.; Francis S.G.; Fuzesi L.; Nostro A.; Tesdahl E.; Goal-directed perfusion methodology for determining oxygenator performance during clinical cardiopulmonary bypass. J Extra Corpor Technol 2017,49(2),81-92","journal-title":"J Extra Corpor Technol"},{"key":"ref=81","first-page":"613","volume":"54","author":"Liu G.","year":"2016","unstructured":"Liu G.; Zeng Q.D.; Zheng Z.; Wang G.Y.; Diao X.L.; Zhang X.; Ji B.Y.; Clinical application of modified minimally cardiopulmonary bypass: compared with conventional cardiopulmonary bypass. Zhonghua Wai Ke Za Zhi 2016,54(8),613-616","journal-title":"Zhonghua Wai Ke Za Zhi"},{"key":"ref=82","doi-asserted-by":"publisher","first-page":"E280","DOI":"10.1111\/aor.12744","volume":"40","author":"Basciani R.","year":"2016","unstructured":"Basciani R.; Kr\u00f6ninger F.; Gygax E.; Jenni H.; Reineke D.; Stucki M.; Hagenbuch N.; Carrel T.; Eberle B.; Erdoes G.; Cerebral microembolization during aortic valve replacement using minimally invasive or conventional extracorporeal circulation: a randomized trial. Artif Organs 2016,40(12),E280-E291","journal-title":"Artif Organs"},{"key":"ref=83","first-page":"70","volume":"19","author":"Pascale F.","year":"1985","unstructured":"Pascale F.; Removal of gaseous microemboli from extracorporeal circulation. Med Instrum 1985,19(2),70-72","journal-title":"Med Instrum"},{"key":"ref=84","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1016\/1053-0770(94)90205-4","volume":"8","author":"Joffe D.","year":"1994","unstructured":"Joffe D.; Silvay G.; The use of microfiltration in cardiopulmonary bypass. J Cardiothorac Vasc Anesth 1994,8(6),685-692","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"ref=85","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1097\/MAT.0b013e318186d32a","volume":"54","author":"Miller A.","year":"2008","unstructured":"Miller A.; Wang S.; Myers J.L.; Undar A.; Gaseous microemboli detection in a simulated pediatric CPB circuit using a novel ultrasound system. ASAIO J 2008,54(5),504-508","journal-title":"ASAIO J"},{"key":"ref=86","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1177\/0267659111430560","volume":"27","author":"Dogal N.M.","year":"2012","unstructured":"Dogal N.M.; Mathis R.K.; Lin J.; Qiu F.; Kunselman A.; Undar A.; Evaluation of three hollow-fiber membrane oxygenators without integrated arterial filters for neonatal cardiopulmonary bypass. Perfusion 2012,27(2),132-140","journal-title":"Perfusion"},{"key":"ref=87","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1177\/0267659112475106","volume":"28","author":"Strother A.","year":"2013","unstructured":"Strother A.; Wang S.; Kunselman A.R.; \u00dcndar A.; Handling ability of gaseous microemboli of two pediatric arterial filters in a simulated CPB model. Perfusion 2013,28(3),244-252","journal-title":"Perfusion"},{"key":"ref=88","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1051\/ject\/201648019","volume":"48","author":"Reagor J.A.","year":"2016","unstructured":"Reagor J.A.; Holt D.W.; Removal of gross air embolization from cardiopulmonary bypass circuits with integrated arterial line filters: a comparison of circuit designs. J Extra Corpor Technol 2016,48(1),19-22","journal-title":"J Extra Corpor Technol"},{"key":"ref=89","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1051\/ject\/201042071","volume":"42","author":"Hawkins J.L.","year":"2010","unstructured":"Hawkins J.L.; Myers G.J.; L\u00e9gar\u00e9 J.F.; Swyer W.; Arterial filter bypass loop: what occurs in this area during cardiopulmonary bypass and are there potential patient implications. J Extra Corpor Technol 2010,42(1),71-74","journal-title":"J Extra Corpor Technol"},{"key":"ref=90","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1177\/0267659113504445","volume":"29","author":"Jabur G.N.","year":"2014","unstructured":"Jabur G.N.; Willcox T.W.; Zahidani S.H.; Sidhu K.; Mitchell S.J.; Reduced embolic load during clinical cardiopulmonary bypass using a 20 micron arterial filter. Perfusion 2014,29(3),219-225","journal-title":"Perfusion"},{"key":"ref=91","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1177\/0267659115621614","volume":"31","author":"Jabur G.N.","year":"2016","unstructured":"Jabur G.N.; Sidhu K.; Willcox T.W.; Mitchell S.J.; Clinical evaluation of emboli removal by integrated versus non-integrated arterial filters in new generation oxygenators. Perfusion 2016,31(5),409-417","journal-title":"Perfusion"},{"key":"ref=92","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1051\/ject\/200840021","volume":"40","author":"Riley J.B.","year":"2008","unstructured":"Riley J.B.; Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study. J Extra Corpor Technol 2008,40(1),21-26","journal-title":"J Extra Corpor Technol"},{"key":"ref=93","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1177\/026765919901400204","volume":"14","author":"Baksaas S.T.","year":"1999","unstructured":"Baksaas S.T.; Flom-Halvorsen H.I.; Ovrum E.; Videm V.; Mollnes T.E.; Brosstad F.; Svennevig J.L.; Leucocyte filtration during cardiopulmonary reperfusion in coronary artery bypass surgery. Perfusion 1999,14(2),107-117","journal-title":"Perfusion"},{"key":"ref=94","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.1016\/j.athoracsur.2004.04.040","volume":"78","author":"Karaiskos T.E.","year":"2004","unstructured":"Karaiskos T.E.; Palatianos G.M.; Triantafillou C.D.; Kantidakis G.H.; Astras G.M.; Papadakis E.G.; Vassili M.I.; Clinical effectiveness of leukocyte filtration during cardiopulmonary bypass in patients with chronic obstructive pulmonary disease. Ann Thorac Surg 2004,78(4),1339-1344","journal-title":"Ann Thorac Surg"},{"key":"ref=95","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1051\/ject\/2003352139","volume":"35","author":"Schneider S.","year":"2003","unstructured":"Schneider S.; Gunasinghe H.; Sistino J.; Blackwell M.; Spinale F.; Effects of leukocyte depletion filters on matrix metalloproteinase activation in an extracorporeal circulation circuit. J Extra Corpor Technol 2003,35(2),139-142","journal-title":"J Extra Corpor Technol"},{"key":"ref=96","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1177\/026765919300800608","volume":"8","author":"Palanzo David A.","year":"1993","unstructured":"Palanzo David A.; Manley Norman J.; Montesano Ralph M.; Yeisley Geary L.; Gordon David. Clinical evaluation of the LeukoGuard (LG-6) arterial line filter for routine open-heart surgery. Perfusion 1993,8(6),489-496","journal-title":"Perfusion"},{"key":"ref=97","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1007\/PL00000316","volume":"51","author":"Scholz M.","year":"2002","unstructured":"Scholz M.; Simon A.; Matheis G.; Dzemali O.; Henrich D.; Kleine P.; Wimmer-Reinecker G.; Moritz A.; Leukocyte filtration fails to limit functional neutrophil activity during cardiac surgery. Inflamm Res 2002,51(7),363-368","journal-title":"Inflamm Res"},{"key":"ref=98","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1016\/j.athoracsur.2005.04.021","volume":"80","author":"Leal-Noval S.R.","year":"2005","unstructured":"Leal-Noval S.R.; Amaya R.; Herruzo A.; Hern\u00e1ndez A.; Ord\u00f3\u00f1ez A.; Mar\u00edn-Niebla A.; Camacho P.; Effects of a leukocyte depleting arterial line filter on perioperative morbidity in patients undergoing cardiac surgery: a controlled randomized trial. Ann Thorac Surg 2005,80(4),1394-1400","journal-title":"Ann Thorac Surg"},{"key":"ref=99","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1016\/j.jtcvs.2004.07.061","volume":"129","author":"Ilmakunnas M.","year":"2005","unstructured":"Ilmakunnas M.; Pesonen E.J.; Ahonen J.; R\u00e4m\u00f6 J.; Siitonen S.; Repo H.; Activation of neutrophils and monocytes by a leukocyte-depleting filter used throughout cardiopulmonary bypass. J Thorac Cardiovasc Surg 2005,129(4),851-859","journal-title":"J Thorac Cardiovasc Surg"},{"key":"ref=100","doi-asserted-by":"publisher","first-page":"414","DOI":"10.5812\/ircmj.10912","volume":"15","author":"Taghipour H.","year":"2013","unstructured":"Taghipour H.; Shafiei H.; Assar O.; Ghiasi M.S.; The effect of systemic arterial-line leukocyte filtration on the outcome of adult patients undergoing cardiac surgery. Iran Red Crescent Med J 2013,15(5),414-417","journal-title":"Iran Red Crescent Med J"}],"container-title":["Current Topics in Medicinal Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/eurekaselect.com\/article\/download\/177330","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T20:48:46Z","timestamp":1695502126000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.eurekaselect.com\/177330\/article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,22]]},"references-count":100,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1,22]]}},"alternative-id":["LiveAll1"],"URL":"https:\/\/doi.org\/10.2174\/1568026619666191210161013","relation":{},"ISSN":["1568-0266"],"issn-type":[{"value":"1568-0266","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1,22]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2019-08-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-10-01","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-10-20","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-01-22","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}